Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 | SIMATIC S7-1200 AC/DC/Relay Compact CPUs
Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 | SIMATIC S7-1200 AC/DC/Relay Compact CPUs

Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 | SIMATIC S7-1200 AC/DC/Relay Compact CPUs Item NO.: 2927192

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 | SIMATIC S7-1200 AC/DC/Relay Compact CPUs
Item NO. 2927192
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-26

Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 | SIMATIC S7-1200 AC/DC/Relay Compact CPUs
CPU 1211C / 1212C
SIEMENS · VERIFIED TECHNICAL RECORD
Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 | SIMATIC S7-1200 AC/DC/Relay Compact CPUs

Two AC-supplied compact CPUs with DC inputs, relay outputs and integrated analog inputs.

01

Product Information

Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 are SIMATIC S7-1200 compact CPUs with an 85–264 V AC supply, 24 V DC digital inputs, relay outputs and two integrated 0–10 V analog inputs. The pair uses the same 90 × 100 × 75 mm housing while offering different onboard point counts and expansion capacity.

On Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0, the relay contacts switch externally powered loads and the digital inputs use separate 24 V DC field references. CPU 1211C provides six inputs and four relay outputs; CPU 1212C raises those totals to eight inputs and six relay outputs.

Expansion planning distinguishes Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 even though their cabinet dimensions match. Both accept one signal board and three communication modules, but CPU 1211C has no signal-module position while CPU 1212C supports two right-side signal modules.

Official technical figure for Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0
02

Technical Data

Technical Item 6ES7211-1BE40-0XB0 6ES7212-1BE40-0XB0
Brand Siemens
Product Name CPU 1211C AC/DC/relay CPU 1212C AC/DC/relay
Country Germany
Supply Voltage 85–264 V AC, 47–63 Hz
Digital Inputs 6 × 24 V DC 8 × 24 V DC
Digital Outputs 4 relay outputs, 2 A 6 relay outputs, 2 A
Integrated Analog Inputs 2 × 0–10 V
Program/Data Memory 75 KB 100 KB
PROFINET Interface 1 port
Signal Boards 1
Signal Modules 0 2
Communication Modules 3
Dimensions (W × H × D) 90 × 100 × 75 mm
03

System Integration

Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 combine controller, Ethernet and onboard field I/O, but they support different expansion paths. Integration begins by choosing the CPU whose onboard points and right-side growth match the machine, then connecting power, field circuits and network devices to that exact hardware identity.
01

Select the expansion architecture

Use Siemens 6ES7211-1BE40-0XB0 when the onboard I/O, one signal-board position and permitted communication modules cover the machine. Select Siemens 6ES7212-1BE40-0XB0 when the design also requires supported right-side signal modules; changing the CPU later changes the hardware configuration and address map.

02

Separate control and load circuits

Supply Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 according to the controller wiring plan, then feed relay loads from the properly protected external circuits required by those loads. Keep input commons, relay groups and analog references identifiable so one field supply is not assumed to power every circuit.

03

Connect the engineering network

Assign the Ethernet identity of Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 in the project before connecting plant devices. Verify programming access first, then add supported PROFINET or TCP services and document every external device address used by the application.

04

Configuration and Programming

A project for Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 must follow the exact installed CPU and channel layout. The commissioning sequence is hardware selection, I/O assignment, expansion configuration, program download and controlled point-to-point testing.
01

1. Reconcile the cabinet build

Read the label on Siemens 6ES7211-1BE40-0XB0 or Siemens 6ES7212-1BE40-0XB0 and compare the actual CPU, signal board and right-side units with the device view before coding begins. Correct the project structure at this stage so later tag assignments follow the cabinet rather than an earlier controller layout.

02

2. Map and scale field points

Map the standard digital, relay and analog channels of Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 to named program variables. Apply debounce, interlock and analog scaling logic according to the connected device rather than copying addresses from a different CPU size.

03

3. Commission one group at a time

Download the complete configuration to Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0, confirm CPU startup and test inputs before energizing output loads. Prove relay groups, analog values and communication separately so a field-wiring fault is not hidden by a simultaneous full-machine start.

05

Product Questions

Why do outputs on Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 indicate ON while the load is off?

Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 use relay contacts that do not generate load voltage. Check the external source, relay common, output terminal, protection device and return conductor.

What changes when a project moves between Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0?

The Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 pair differs in onboard I/O, memory and signal-module capacity. Rebuild the hardware configuration and verify every address rather than changing only the catalog number.

Why can analog readings drift on Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0?

For Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0, check the 0–10 V reference, shield routing and separation from relay/load conductors. A shared noisy reference can disturb both integrated analog channels.

Can Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 be powered from 24 V DC?

No. Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 are the AC-supplied executions rated for 85–264 V AC. Their 24 V DC digital inputs do not change the CPU supply requirement.

How is an expansion mismatch diagnosed on Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0?

Compare the installed hardware order with the project for Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0. CPU 1211C cannot accept the two signal modules available to CPU 1212C, so a copied rack definition may be invalid.

What should be reviewed before replacing Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0?

Record the exact Siemens 6ES7211-1BE40-0XB0 / 6ES7212-1BE40-0XB0 CPU, firmware, program, PROFINET settings, terminal map and attached modules. Matching the housing alone is not enough to preserve the machine configuration.

06

Why Choose Moore Automation

Moore Automation industrial supply services

Moore Automation

https://www.mvme.cn

Moore Automation keeps industrial-parts enquiries focused on the requested model, quantity and available product documentation.

The service scope combines enquiry handling, record coordination and a named contact without presenting brand authorization, fixed delivery or guaranteed stock claims.

Clear recordsExact requests remain visible.
Coordinated reviewDetails are handled together.
Named contactLeonia supports follow-up.
07

Product Recommendations

FoxboroP0926EQ
Bosch RexrothDKC02.1-040-7-FW
Vibro-MeterCPUM Mk2
YokogawaA2FV70D-A411000/HKU
ProSoftMVI69L-MBTCP
Woodward5466-1247
HoneywellFC-USI-0002
GEIC660BBA024
Rockwell Automation1734-IR2
Siemens6ES7288-3AR02-0AA0
ABBCI871AK01
EmersonPR6426-000-030
Bently Nevada330101-00-40-05-02-00
B&RX20AT4222
ABB BaileyBRC410
MotorolaMVME172-433A
TriconexTricon 4610
HIMAF7126
FoxboroP0914ST
Bosch RexrothDKC03.1-040-7-FW
Vibro-MeterIOCN Mk2
YokogawaVI702
ProSoftILX34-MBS232
Woodward5466-1250
HoneywellFC-QPP-0002
GEIC660BBA025
Rockwell Automation1734-IT2I
Siemens6ES7288-3AR04-0AA0
ABBTU810V1
EmersonPR6426-010-140
Bently Nevada330101-00-40-10-02-00
B&RX20AT6402
ABB BaileyBRC400
MotorolaMVME172PA-652SE
TriconexTricon 4610X
HIMAF35 03/4
FoxboroFBM203
Bosch RexrothDKC03.3-040-7-FW
Vibro-MeterCPUR2
YokogawaPW481-51
ProSoftPLX31-MBTCP-MBS
Woodward5466-1347
GEIC660BBA026
Rockwell Automation1734-FPD
Siemens6ES7288-5DQ01-0AA0
ABBTU811V1
EmersonPR9350-02
Bently Nevada330101-00-40-10-02-05
B&RX20AI1744
ABB BaileyBRC300
MotorolaMVME2301
TriconexTRICONEX 3501E
HIMAF30
FoxboroFBM203B
Bosch RexrothDKC04.1-040-7-FW
Vibro-MeterIOCR2
YokogawaALR121-S51
ProSoftPLX31-MBTCP-MBS4
Woodward5453-754
GEIC660BBA100
08

Sales Enquiries

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.