Controller partner
The CPUM Mk2 processes rack data while IOCN Mk2 600-051 exposes the configured external paths.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Meggitt Vibro-Meter IOCN Mk2 600-051 | VM600Mk2 communications interface module |
| Item NO. | 2919455 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | VIBRO METER |
| Brand | OTHER PRODUCTS |
| Creation Time | 2026-10-14 |
Meggitt Vibro-Meter VM600 hardware
At the communications layer, Meggitt Vibro-Meter IOCN Mk2 600-051 is the VM600Mk2 interface module. It links the rack controller to the external Ethernet and fieldbus paths used by the configured monitoring system.
IOCN Mk2 600-051 operates with a CPUM Mk2 rather than acting as a measurement card. Its J2 and J4 connectors serve the fieldbus path, while J6 and J7 serve the Ethernet path, keeping the two external connection types distinct.
Within the rack, IOCN Mk2 600-051 exchanges data with the controller through the VM600Mk2 connection. The selected protocol and cable route are functions of the installed interface arrangement, not of a sensor channel.
| Technical item |
|
|---|---|
| Brand | Meggitt Vibro-Meter |
| Product type | Communications interface module |
| Product family | VM600Mk2 |
| Part number | 600-051 |
| Card family | IOCN Mk2 |
| Paired controller | CPUM Mk2 |
| Rack interface | VM600Mk2 connection |
| Fieldbus connectors | J1/J2 for FIELDBUS1; J4/J5 for FIELDBUS2 |
| Ethernet connectors | J6 and J7 |
| Interface role | External network and fieldbus routing |
| Channel role | Communications, not sensor input |
| Rack compatibility | VM600Mk2 ABE04x system rack |
| Module position | Rear of rack, directly behind CPUM Mk2 |
| Backplane connection | Two connectors to the rack backplane |
| Fieldbus ports | 2 interfaces, serial and Ethernet connector per port |
| PROFIBUS interface | RS-485, up to 12 Mbps with automatic baud detection |
| Modbus TCP interface | 10/100BASE-TX, up to 100 Mbps |
| Isolation | 700 VRMS RS-485; 1500 VRMS fieldbus Ethernet |
| Input protection | EMI and signal-surge protection |
| Configuration path | CPUM Mk2 and VibroSight software |
| Status indication | Ethernet and fieldbus link/activity LEDs |
| Rack-side source | Paired CPUM Mk2 controller |
| Protocol layer | Configured Ethernet or fieldbus service |
| Cable grouping | J2/J4 fieldbus; J6/J7 Ethernet |
| Controller partner | CPUM Mk2 rack controller |
IOCN Mk2 600-051 occupies the communications layer beside the CPUM Mk2 controller in the VM600Mk2 rack.
The CPUM Mk2 processes rack data while IOCN Mk2 600-051 exposes the configured external paths.
The two cards exchange their internal data through the VM600Mk2 rack connection.
The IOCN connectors carry the selected Ethernet or fieldbus connection away from the rack.
The connector groups on IOCN Mk2 600-051 keep the external protocol routes separate.
These connectors serve the configured fieldbus route and are not sensor terminals.
IOCN Mk2 600-051 is the communications interface paired with CPUM Mk2 in the VM600Mk2 rack. The controller handles rack processing while the IOCN Mk2 exposes the configured external Ethernet or fieldbus path.
In the rack path for IOCN Mk2 600-051, trace the J2/J4 fieldbus path separately from the J6/J7 Ethernet path, then check the paired CPUM Mk2 and the rack connection. The two connector groups serve different external communication routes.
No. IOCN Mk2 600-051 identifies the interface card, not the protocol selected by the installed configuration. The connected port, cable and configured communication service must be checked together.
IOCN Mk2 600-051 routes system communications between the rack and external devices. Measurement cards provide the signal channels, so replacing a channel card with a communications interface would change the signal path.
When documenting IOCN Mk2 600-051, verify the IOCN Mk2 rack position, the CPUM Mk2 pairing, the selected connector group and the protocol assigned to that path. This confirms that the cable is connected to the intended interface rather than to a measurement input.
During a IOCN Mk2 600-051 review, check whether the CPUM Mk2 is exchanging data over the backplane before testing the external IOCN Mk2 connector path. Internal rack data and external protocol traffic are separate checks in the same VM600Mk2 communication chain.
https://www.mvme.cn/
Moore Automation keeps the submitted model visible beside the enquiry details, which helps separate a specific card or interface from a wider product family.
The contact route is presented with the model and destination fields so technical questions can be answered against the same request record.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found