CE281 444-281-000-111 separates high-temperature sensing from lower-temperature signal conversion while keeping both stages inside one sealed, two-wire measurement assembly.
-
01
Two temperature zones
The sensor head of CE281 444-281-000-111 operates continuously from -55 to +260 °C. Its attached charge-to-current electronics have a separate -40 to +125 °C continuous range, so the hose places conversion away from the hottest point.
-
02
Current-modulated scale
The centre-mounted shear element produces charge and the attached electronics convert it to a 10 µA/g current modulation. This low-impedance two-wire signal travels to the external galvanic separator or compatible monitoring input.
-
03
Mechanical and electrical limits
CE281 444-281-000-111 measures from 0.0001 to 200 g peak and has a typical 25 kHz mounted resonance. Those performance values apply to the complete welded sensor, cable and electronics assembly.









No related record found