Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE IC695CRU320-EH PACSystems RX3i Redundancy CPU
GE IC695CRU320-EH PACSystems RX3i Redundancy CPU

GE IC695CRU320-EH PACSystems RX3i Redundancy CPU Item NO.: 2943285

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE IC695CRU320-EH PACSystems RX3i Redundancy CPU
Item NO. 2943285
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-20

GE IC695CRU320-EH PACSystems RX3i Redundancy CPU
GERX3i REDUNDANCY
Hot-standby controller coordination

GE IC695CRU320-EH PACSystems RX3i Redundancy CPU

A 1 GHz redundancy CPU with synchronized control state.

Product facts

Product Overview

IC695CRU320-EH is a PACSystems RX3i redundancy CPU with a 1 GHz processor and 64 MB of user memory. It serves as the head-end controller in a hot-standby architecture where two controller systems maintain coordinated application and process state.

Each IC695CRU320-EH executes the configured control application while the redundancy link keeps the active and backup roles aligned. The active unit controls the I/O path; the backup tracks the synchronized state so a managed role transfer can continue control from the paired system.

The redundancy design around IC695CRU320-EH depends on matched projects, consistent hardware layouts, a healthy synchronization path and defined shared-I/O communication. Controller role, synchronization status and fault history must therefore be interpreted together rather than from a single RUN indication.

Reference values

Technical Specifications

Brand
GE
Model
IC695CRU320-EH
Product Name
PACSystems RX3i Redundancy CPU
Country
Not specified
Series
PACSystems RX3i
Processor Speed
1 GHz
User Memory
64 MB
Controller Role
Hot-standby redundancy CPU
Module Position
Head-end controller
Redundancy State
Active or backup role
Project Requirement
Matched redundancy applications
Synchronization
Controller state transferred across redundancy link
I/O Control
Owned by active controller
Diagnostics
Role, synchronization and controller fault records
Backplane Power
1000 mA at 3.3 V DC; 1200 mA at 5 V DC
Product behavior

Monitoring and Control

IC695CRU320-EH uses two controller roles to keep one process-control context available across a managed switchover.

ACTIVE ROLE

Own the live I/O path

The active CPU executes the application against the shared process data and issues the authoritative output state.

BACKUP ROLE

Track synchronized state

The backup follows the application context and received controller state without acting as a second independent owner of the same outputs.

ROLE CHANGE

Transfer control deliberately

A switchover changes which controller owns the process path, so role and synchronization status must be stable before the transition is accepted.

System context

System Integration

IC695CRU320-EH redundancy depends on matched controller targets, communication paths and shared-I/O design.

MATCHED SYSTEMS

Keep hardware and project context aligned

Both sides use coordinated applications and compatible rack configurations so the backup can interpret the synchronized state.

REDUNDANCY LINK

Preserve the controller relationship

The dedicated synchronization path carries role and state information separately from ordinary plant communications.

SHARED I/O

Maintain one process view

The architecture presents the field system to whichever CPU is active; inconsistent network or I/O configuration breaks that common view.

Practical checks

Frequently Asked Questions

What should be captured before an IC695CRU320-EH switchover test?

Record both IC695CRU320-EH roles, synchronization state, fault history, shared-I/O status, network alarms and process conditions before testing.

How should an intermittent IC695CRU320-EH role change be investigated?

Correlate IC695CRU320-EH role events with redundancy-link diagnostics, power history, controller faults and shared-network alarms.

Why is an IC695CRU320-EH backup not synchronized?

For IC695CRU320-EH, compare project versions, hardware layouts, redundancy-link health, role settings and fault tables on both controllers.

Which differences matter between paired IC695CRU320-EH systems?

Check IC695CRU320-EH firmware, application checksum, hardware configuration, redundancy parameters and communication-module layout on both sides.

Can two IC695CRU320-EH controllers both command the same outputs independently?

No. The IC695CRU320-EH redundancy architecture maintains one active control owner while the backup tracks synchronized state.

Why can IC695CRU320-EH RUN status be insufficient for redundancy health?

IC695CRU320-EH RUN indicates application execution, but role, synchronization and shared-I/O communication must also be healthy for standby readiness.

Moore Automation

Obsolete Parts Support

Moore Automation

https://www.mvme.cn/

The company reference includes discontinued, obsolete and hard-to-find automation parts as enquiry categories. Moore Automation can review IC695CRU320-EH by its complete suffix, quantity and installed-system context while keeping any alternative model as a separate, unconfirmed record rather than assuming interchangeability.

Installed-base enquiry
Exact suffix retained
Record review
Available information coordinated
No assumed substitute
Different models kept separate
Moore Automation company information image
CompanyMoore Automation
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.