Establish the range baseline
In 0–20 mA mode, zero current maps to zero counts; in standard 4–20 mA mode, 4 mA maps to zero counts. The project must interpret the word using the matching range.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE IC694ALG223-BB RX3i 16-Channel Analog Input Module |
| Item NO. | 2942603 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-11-19 |
Scaled current-loop acquisition
A 16-channel analog module that maps 0–20 mA and 4–20 mA field signals into controller data.
GE IC694ALG223-BB is a sixteen-channel analog current-input module for PACSystems RX3i. The module accepts 0–20 mA, 4–20 mA and enhanced 4–20 mA ranges and writes each enabled channel into a contiguous analog-input word.
A 12-bit converter in GE IC694ALG223-BB scales the active range into a signed 16-bit controller value. Standard 0–20 mA uses zero to 32,000 counts, standard 4–20 mA uses zero to 32,000 counts across the live span, and the enhanced range extends below 4 mA to negative values.
GE IC694ALG223-BB refreshes all sixteen channels in about six milliseconds and uses a 250 Ω measurement path with an approximately 19 Hz input filter. An external 20–30 V DC supply powers the field-side circuitry and can feed transmitter loops through the terminal assembly.
The selected current range determines the numerical baseline, span and diagnostic space presented by GE IC694ALG223-BB.
In 0–20 mA mode, zero current maps to zero counts; in standard 4–20 mA mode, 4 mA maps to zero counts. The project must interpret the word using the matching range.
Twenty milliamps maps to approximately 32,000 counts in the standard ranges, giving application logic a consistent high-end value for engineering scaling.
Enhanced 4–20 mA mode assigns negative values below 4 mA so the controller can separate valid low process current from an under-range or open-loop condition.
GE IC694ALG223-BB links powered transmitters, field terminals and the RX3i analog reference table as one signal chain.
The external 24 V source can be distributed through the terminal tie point, while the return and current-input terminals complete the measurement path.
The configured starting address and channel count determine the block of analog-input words used by the module, so later modules must not overlap that allocation.
Controller logic or an analog scaling block converts raw counts into pressure, flow, temperature or another engineering unit using the transmitter range.
GE IC694ALG223-BB uses different range definitions: 0 mA is the baseline in 0–20 mA mode, while 4 mA is the baseline in standard 4–20 mA mode.
Measure the actual loop current for the GE IC694ALG223-BB channel and compare it with the raw word and selected scaling, taking care not to open the loop unintentionally.
For GE IC694ALG223-BB, common noise across channels points to field-supply ripple, shield termination, common routing or cabinet grounding before individual channel hardware.
For GE IC694ALG223-BB, retain the slot, starting address, channel count, range per channel, transmitter spans, alarm limits and terminal map.
GE IC694ALG223-BB raw counts must be interpreted with the same 0–20 mA, 4–20 mA or enhanced range used in the module configuration and scaling logic.
For GE IC694ALG223-BB, check module health, backplane status, configured channel count, analog-reference allocation, field supply and whether controller logic is reading the correct words.
Moore Automation maintains a clear enquiry trail for industrial automation parts. For GE IC694ALG223-BB, exact model identification, requested quantity, related system information, packing requirements and destination can remain visible throughout the commercial process.
| Brand / Model | Brand / Model | Brand / Model | Brand / Model |
|---|---|---|---|
| ABBPM858K01 3BSE082895R1 | Rockwell Automation1394C-SJT05-A | GEIC600CB504 | Siemens6ES7193-4CA30-0AA0 |
| ABBPM858K02 3BSE082896R1 | Rockwell Automation1394C-SJT10-A | GEIC600CB507 | Siemens6ES7193-4CB30-0AA0 |
| ABBPM860AK01 3BSE066495R1 | Rockwell Automation2094-BC01-M01-S | GEIC600CP620 | Siemens6ES7193-4CD30-0AA0 |
| ABBPM860K01 3BSE018100R1 | Rockwell Automation2094-BC01-MP5-S | GEIC600CP630 | Siemens6ES7193-4CE00-0AA0 |
| ABBPM861AK01 3BSE018157R1 | Rockwell Automation2094-BC02-M02-S | GEIC610ABM100 | Siemens6ES7193-4CE10-0AA0 |
| ABBPM861AK02 3BSE018160R1 | Rockwell Automation2094-BC04-M03-S | GEIC610CBL105 | Siemens6SL3210-5BE17-5UV0 |
| ABBPM862K01 3BSE076940R1 | Rockwell Automation2094-BC07-M05-S | GEIC610CCM100 | ABBPM862K02 3BSE081636R1 |
| Rockwell Automation2094-BM01-S | GEIC610CCM105 | ABBPM863K01 3BSE088381R1 | Rockwell Automation2094-BM02-S |
| GEIC610CCM110 | ABBPM863K02 3BSE088382R1 | Rockwell Automation2094-BM03-S | GEIC610CPU105 |
| ABBPM864AK01 3BSE018161R1 | Rockwell Automation2094-BMP5-M | GEIC610CPU106 | ABBPM864AK02 3BSE018164R1 |
| Rockwell Automation2094-BMP5-S | GEIC610IAL101 | ABBPM865K01 3BSE031151R1 | Rockwell Automation2098-DSD-030 |
| GEIC610IAL115 | Rockwell Automation2098-DSD-150 | GEIC610MDL125 | Rockwell Automation2098-DSD-HV220 |
| GEIC610MDL158 | Rockwell Automation2198-D032-ERS4 | GEIC610MDL185 | Rockwell Automation2198-D057-ERS3 |
| GEIC610ODD100 | Rockwell Automation2198-P070 | GEIC610ODR101 | Rockwell Automation2198-P208 |
| GEIC610PRG105 | Rockwell Automation2198-S086-ERS3 | GEIC610PWR101 | Rockwell Automation2198-S160-ERS3 |