Home>GE>GE Fanuc IC693ALG223-FR / IC693ALG392-CF Series 90-30 Analog I/O Modules
GE Fanuc IC693ALG223-FR / IC693ALG392-CF Series 90-30 Analog I/O Modules

GE Fanuc IC693ALG223-FR / IC693ALG392-CF Series 90-30 Analog I/O Modules Item NO.: 2945590

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC693ALG223-FR / IC693ALG392-CF Series 90-30 Analog I/O Modules
Item NO. 2945590
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-11-27

GE Fanuc IC693ALG223-FR / IC693ALG392-CF Series 90-30 Analog I/O Modules
GE FanucSeries 90-30 / RX3i compatible I/O
Sixteen current inputs and eight configurable outputs

GE Fanuc IC693ALG223-FR / IC693ALG392-CF Series 90-30 Analog I/O Modules

Inputs16 current
Outputs8 analogue
Supply24 VDC
01
Product record

Hardware Information

GE Fanuc IC693ALG223-FR is a sixteen-channel analogue current input module, while IC693ALG392-CF is an eight-channel current and voltage output module. Both belong to the Series 90-30 I/O family, but one brings field current into controller memory and the other converts controller commands into field signals.

The inputs of IC693ALG223-FR share the module current-sensing and loop-supply boundary defined by its terminals. In contrast, each channel of IC693ALG392-CF can be assigned a supported current or voltage output range, and all eight outputs are refreshed during the module update cycle.

External 24 VDC is part of both field interfaces for different reasons: IC693ALG223-FR uses it with the current-input loop arrangement, whereas IC693ALG392-CF requires isolated user power for the output circuits. The complete FR and CF suffixes remain procurement identities and are not used to transfer one module's function to the other.

02
Verified model data

Configuration Specifications

Models
IC693ALG223-FR / IC693ALG392-CF
Brand
GE Fanuc / Emerson
Product types
16-channel current input / 8-channel current-voltage output
Platform
Series 90-30; supported RX3i backplanes
ALG223 input channels
16 single-ended current inputs
ALG223 input ranges
0–20 mA and 4–20 mA
ALG223 loop interface
External 24 VDC loop supply path
ALG392 output channels
8 single-ended outputs
ALG392 output ranges
0–10 V, ±10 V, 0–20 mA, 4–20 mA
ALG392 update
All eight channels in 8 ms
ALG392 conversion
15 or 16 bit by selected range
ALG392 user supply
External isolated 24 VDC
ALG392 current-loop diagnostic
Open-wire fault reporting
Revision identities
FR and CF retained exactly
03
Product operation

Current Input Path

The sixteen input channels convert field-loop current into controller data through a shared module structure.

Loop entry

Each transmitter current enters its numbered channel terminal and returns through the defined common path.

Sensing

The module converts loop current into a digital input value for the assigned analogue reference.

Loop power

External 24 VDC supports the published loop-supply arrangement rather than the backplane logic alone.

Controller data

Sixteen channel results are delivered as input words with module status available to the controller.

The loop supply, field return and input reference belong to the same measurement chain. Following that chain from transmitter current to the assigned controller word prevents a missing loop source from being mistaken for a scaling or program problem.

04
System behavior

Output Range Control

The eight output channels translate controller commands into the electrical range selected for each point.

Range assignment

Each output is configured for one of the supported current or voltage ranges.

Digital command

The controller output word is scaled across the selected electrical span.

Field drive

External 24 VDC provides the isolated user-power boundary required by the output circuits.

Fault response

Current-mode open-wire diagnostics and configured hold-last or default behavior define abnormal operation.

The controller command has meaning only after the channel range and external field-power path are both established. Diagnostic and fallback behavior then determines what the field circuit receives when the loop opens or controller communication is interrupted.

05
Practical model checks

Technical Q&A

Why must IC693ALG223-FR and IC693ALG392-CF remain separate in an I/O list?

IC693ALG223-FR is an input module and IC693ALG392-CF is an output module. Similar analogue terminology does not make their direction, terminals or controller references interchangeable.

What should be checked when one IC693ALG223-FR loop reads zero?

Verify loop power, polarity, channel terminal, common return and transmitter current before changing scaling in the controller.

How is an IC693ALG392-CF current-output open wire distinguished from a zero command?

Read the module diagnostic status together with the commanded output. An open-wire indication identifies an incomplete current loop even when the requested numeric value is low.

Can IC693ALG392-CF output ranges be mixed on one module?

Yes, channels can use supported ranges independently, but the project configuration and field wiring must identify the range assigned to every output.

What information belongs with an IC693ALG223-FR replacement request?

Include the complete FR label, rack slot, loop-supply arrangement, channel map, signal ranges and the controller or remote-carrier context.

Why should external 24 VDC be measured at IC693ALG392-CF during commissioning?

The backplane can communicate with the module while the isolated field-output supply is missing or outside its allowed range. Measure user power at the module terminals under load.

06
Moore Automation

Analog I/O Code Review

Moore Automation Limited

https://www.mvme.cn/

Moore Automation records input and output modules as different product classes even when they share a controller platform. Full suffixes, signal direction and requested quantity remain visible.

One account contact coordinates identification review, quotation details, documents and shipment updates.

Input/output separatedSuffixes preservedSignal type recordedOne contact route
07
Separate product records

Product Selection

Siemens6ES7288-2DT08-0AA0
GEIC670MDL641
Allen-Bradley1734-TOP
Bently Nevada3500/05-01-02-01-00-01
B&RX20DI9371
ABBPM865K02
MotorolaMVME162-001
FoxboroRH914SQ
Bosch RexrothHCS02.1E-W0012-A-03-NNNN
EmersonKL2102X1-BA1
Vibro-MeterCPUR2
Triconex4351B
YokogawaAAV141-S53/K4A00
Woodward9907-1200
ProSoftPLX32-EIP-MBTCP
Emerson EPROPR6424-010-140
HIMAF30
ICS TriplexT8100C
HoneywellFC-TSDO-0824
Siemens6ES7288-2DT16-0AA0
GEIC670MDL642
Allen-Bradley1734-TB
Bently Nevada3500/15-05-05-01
B&RX20DO9322
ABBPM862K02
MotorolaMVME162-014A
FoxboroRH916XG
Bosch RexrothHCS02.1E-W0028-A-03-NNNN
EmersonCE4006P2
Vibro-MeterIOCR2
Triconex9662X-610RF
YokogawaAAI143-H53/K4A00
Woodward9907-173
ProSoftMVI69E-MBTCP
Emerson EPROPR6426-000-030
HIMAF60
ICS TriplexT8300C
HoneywellCC-MCAR01
Siemens6ES7288-2DR32-0AA0
GEIC670MDL643
Allen-Bradley1734-ARM
Bently Nevada3500/22M-01-01-01
B&RX20DI9372
ABBPM857K02
MotorolaMVME162-020A
FoxboroFBM214B
Bosch RexrothHCS02.1E-W0070-A-03-NNNN
EmersonVE4022
Vibro-Meter200-560-101-015
Triconex9770X
YokogawaA2MDV843-0S1000
Woodward8237-2596
ProSoftMVI69L-MBS
Emerson EPROPR6426-010-140
HIMA8/4
ICS TriplexT8800C
HoneywellCC-TDIL10
Siemens6ES7288-2DT32-0AA0
GEIC670MDL644
Allen-Bradley1734-VHSC24

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.