Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules
GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules

GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules Item NO.: 2906797

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules
Item NO. 2906797
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-09-09

GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules
Series Six Communication and Analog Output

GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules

A combined reference for the enhanced local I/O transmitter and two four-channel 12-bit analog voltage output modules.

IC600BF940Enhanced local I/O transmitter
IC600BF941Unipolar analog output module
IC600BF942Bipolar analog output module

Product Description

IC600BF940, IC600BF941 and IC600BF942 share the Series Six rack platform but serve two separate control functions. IC600BF940 is the enhanced Local I/O Transmitter that extends an I/O path to downstream equipment and can suppress its status-byte generation for specific Expanded Channel 1 redundant-processor applications. IC600BF941 and IC600BF942 are four-channel analog output modules.

The analog modules accept 12 bits of binary output data plus a channel selection from the CPU and convert the command to a field voltage. IC600BF941 is cataloged for 0 to +10 Vdc output, while IC600BF942 provides -10 to +10 Vdc bipolar output. On-board jumpers permit individual channel reassignment among supported analog output functions, but calibration and field-loop requirements must still be observed.

The transmitter belongs in the I/O communication path; the two analog modules belong at final-control signal points such as process-control references and motor-speed commands. Record the complete part number, rack location, chain connections, output range and calibration state rather than relying on the shared BF94x prefix.

Technical Specifications

Specification IC600BF940 IC600BF941 IC600BF942
Brand GE Fanuc
Product Type Enhanced local I/O transmitter Unipolar analog output module Bipolar analog output module
Country United States
System Family Series Six / Series Six Plus
Primary Function Interfaces an I/O rack with a downstream I/O device or station Generates 0 to +10 Vdc control outputs Generates -10 to +10 Vdc control outputs
Channels / Path One local I/O transmitter path; supports normal or expanded I/O arrangements 4 analog output channels 4 analog output channels
Conversion Serial I/O-chain transmission 12-bit D/A; 1 part in 4096 12-bit D/A; 1 part in 4096
Indicators CHAIN OK, CHAIN PARITY, ISOLATED POWER and FAULT ENABLED Module status LED Module status LED
Configuration Fault-isolation and status-byte options; downstream isolation Per-channel range jumpers and calibration Per-channel range jumpers and calibration
+5 V Load 34 units 29 units 29 units
Circuit Board 8.15 x 11.0 in (208 x 280 mm) 8.15 x 11.0 x 1.20 in (208 x 280 x 31 mm) 8.15 x 11.0 x 1.20 in (208 x 280 x 31 mm)
Faceplate 12.46 x 1.175 in (317 x 30 mm)
Environment 0 to 60 C operating; 5-95% RH non-condensing

Communication and Analog Control

IC600BF941 / IC600BF942 Typical Voltage Output Connections
IC600BF941 / IC600BF942 Typical Voltage Output Connections · click to enlarge

IC600BF940 separates downstream I/O stations through an isolated transmitter path and provides four front-panel condition indicators for chain and power state.

In an RPU system using conventional I/O on Expanded Channel 1, the enhanced transmitter can disable status-byte generation to avoid the register conflict identified in the GE manual.

IC600BF941 produces four unipolar voltage outputs; IC600BF942 produces four bipolar voltage outputs. Both use 12-bit CPU data and channel selection.

A revision check matters for analog output placement: early A versions are specified for local I/O, while later versions support both local and remote I/O applications.

Configuration and Calibration

Transmitter settings

Document channel mode, fault handling, status-byte selection and every upstream/downstream I/O connection before replacement.

Analog range

Match each channel jumper to the required output mode and verify the external load or loop arrangement.

Calibration

Use the specified calibration connector and measurement equipment, apply low-end and high-end commands, then adjust at the normal operating temperature.

Acceptance

Confirm chain indicators for IC600BF940 and prove commanded output values on all four channels for IC600BF941 or IC600BF942.

Product FAQ

Why is IC600BF940 specified in some redundant-processor Expanded Channel 1 systems?

Its status-byte generation can be disabled so that the conventional I/O status byte does not conflict with registers used by the RPU transfer functions.

What is the output-range difference between IC600BF941 and IC600BF942?

IC600BF941 is the 0 to +10 Vdc version; IC600BF942 is the -10 to +10 Vdc bipolar version.

Can every IC600BF941 or IC600BF942 revision be used in remote I/O?

No. The manual limits the A versions to local I/O and permits later versions in local or remote I/O. Confirm the alpha suffix on the installed module.

How many analog channels do IC600BF941 and IC600BF942 provide?

Each module provides four analog output channels converted from 12-bit CPU data.

What must be verified after installing IC600BF940?

Check isolated power, chain continuity, parity indication, fault-enable state and any status-byte option required by the I/O architecture.

Moore Automation warehouse, service or company activity scene
Moore Automation

Service Commitments

Moore Automation presents four clear service commitments for industrial automation orders: 100% original products, fast delivery, a one-year warranty and a 12-hour online response.

These commitments are applied across the company's supply range for PLC, DCS, drive, HMI, communication and power components.

Contact

ManagerLeonia
WhatsApp+8618030175807

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.