Transmitter settings
Document channel mode, fault handling, status-byte selection and every upstream/downstream I/O connection before replacement.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC600BF940 / IC600BF941 / IC600BF942 Series Six I/O Modules |
| Item NO. | 2906797 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-09-09 |
A combined reference for the enhanced local I/O transmitter and two four-channel 12-bit analog voltage output modules.
IC600BF940, IC600BF941 and IC600BF942 share the Series Six rack platform but serve two separate control functions. IC600BF940 is the enhanced Local I/O Transmitter that extends an I/O path to downstream equipment and can suppress its status-byte generation for specific Expanded Channel 1 redundant-processor applications. IC600BF941 and IC600BF942 are four-channel analog output modules.
The analog modules accept 12 bits of binary output data plus a channel selection from the CPU and convert the command to a field voltage. IC600BF941 is cataloged for 0 to +10 Vdc output, while IC600BF942 provides -10 to +10 Vdc bipolar output. On-board jumpers permit individual channel reassignment among supported analog output functions, but calibration and field-loop requirements must still be observed.
The transmitter belongs in the I/O communication path; the two analog modules belong at final-control signal points such as process-control references and motor-speed commands. Record the complete part number, rack location, chain connections, output range and calibration state rather than relying on the shared BF94x prefix.
| Specification | IC600BF940 | IC600BF941 | IC600BF942 |
|---|---|---|---|
| Brand | GE Fanuc | ||
| Product Type | Enhanced local I/O transmitter | Unipolar analog output module | Bipolar analog output module |
| Country | United States | ||
| System Family | Series Six / Series Six Plus | ||
| Primary Function | Interfaces an I/O rack with a downstream I/O device or station | Generates 0 to +10 Vdc control outputs | Generates -10 to +10 Vdc control outputs |
| Channels / Path | One local I/O transmitter path; supports normal or expanded I/O arrangements | 4 analog output channels | 4 analog output channels |
| Conversion | Serial I/O-chain transmission | 12-bit D/A; 1 part in 4096 | 12-bit D/A; 1 part in 4096 |
| Indicators | CHAIN OK, CHAIN PARITY, ISOLATED POWER and FAULT ENABLED | Module status LED | Module status LED |
| Configuration | Fault-isolation and status-byte options; downstream isolation | Per-channel range jumpers and calibration | Per-channel range jumpers and calibration |
| +5 V Load | 34 units | 29 units | 29 units |
| Circuit Board | 8.15 x 11.0 in (208 x 280 mm) | 8.15 x 11.0 x 1.20 in (208 x 280 x 31 mm) | 8.15 x 11.0 x 1.20 in (208 x 280 x 31 mm) |
| Faceplate | 12.46 x 1.175 in (317 x 30 mm) | ||
| Environment | 0 to 60 C operating; 5-95% RH non-condensing | ||
IC600BF940 separates downstream I/O stations through an isolated transmitter path and provides four front-panel condition indicators for chain and power state.
In an RPU system using conventional I/O on Expanded Channel 1, the enhanced transmitter can disable status-byte generation to avoid the register conflict identified in the GE manual.
IC600BF941 produces four unipolar voltage outputs; IC600BF942 produces four bipolar voltage outputs. Both use 12-bit CPU data and channel selection.
A revision check matters for analog output placement: early A versions are specified for local I/O, while later versions support both local and remote I/O applications.
Document channel mode, fault handling, status-byte selection and every upstream/downstream I/O connection before replacement.
Match each channel jumper to the required output mode and verify the external load or loop arrangement.
Use the specified calibration connector and measurement equipment, apply low-end and high-end commands, then adjust at the normal operating temperature.
Confirm chain indicators for IC600BF940 and prove commanded output values on all four channels for IC600BF941 or IC600BF942.
Its status-byte generation can be disabled so that the conventional I/O status byte does not conflict with registers used by the RPU transfer functions.
IC600BF941 is the 0 to +10 Vdc version; IC600BF942 is the -10 to +10 Vdc bipolar version.
No. The manual limits the A versions to local I/O and permits later versions in local or remote I/O. Confirm the alpha suffix on the installed module.
Each module provides four analog output channels converted from 12-bit CPU data.
Check isolated power, chain continuity, parity indication, fault-enable state and any status-byte option required by the I/O architecture.
Moore Automation presents four clear service commitments for industrial automation orders: 100% original products, fast delivery, a one-year warranty and a 12-hour online response.
These commitments are applied across the company's supply range for PLC, DCS, drive, HMI, communication and power components.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.