Standard-temperature body
PR9268/203-100 uses the standard-temperature vertical construction with an aluminum housing and a 100 °C class boundary.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Emerson PR9268/203-100 / PR9268/601-000 Standard and High-Temperature Velocity Sensors |
| Item NO. | 2944909 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | EMERSON |
| Brand | EMERSON |
| Creation Time | 2026-11-25 |
Emerson PR9268/203-100 / PR9268/601-000 are vertical electrodynamic velocity sensors with different temperature, cable and termination constructions. Both convert absolute housing vibration into a velocity-proportional electrical signal, but their order codes define distinct environmental and wiring boundaries.
PR9268/203-100 is a standard-temperature vertical version with a 10 m armored cable and open wire ends. PR9268/601-000 is a high-temperature vertical version with a 5 m armored cable and Harting connector; its high-temperature construction uses materials selected for the documented 200 °C sensor environment.
The mechanical orientation rules for PR9268/203-100 / PR9268/601-000 remain tied to the vertical moving-coil system. An installation within ±30° does not require sinking current, while an angle extending toward ±60° uses the specified sinking current to keep the internal mass in its operating position.
| Specification | PR9268/203-100 | PR9268/601-000 |
|---|---|---|
| Brand | Emerson | Emerson |
| Product Type | Electrodynamic velocity sensor | Electrodynamic velocity sensor |
| Brand Country | United States | United States |
| Measurement direction | Vertical | Vertical |
| Temperature class | Standard, up to 100 °C | High temperature, up to 200 °C |
| Housing material | Aluminum construction | Stainless-steel construction |
| Cable length | 10 m | 5 m |
| Cable protection | Armored | Armored |
| Termination | Open wire ends | Harting connector |
| Frequency range | 4 to 1000 Hz | 4 to 1000 Hz |
| Nominal sensitivity | 28.5 mV/mm/s | 28.5 mV/mm/s |
| Mounting deviation without sinking current | Up to ±30° | Up to ±30° |
| Mounting deviation with sinking current | Up to ±60° | Up to ±60° |
| Measuring principle | Electrodynamic moving coil | Electrodynamic moving coil |
| Signal form | Velocity-proportional voltage | Velocity-proportional voltage |
Emerson PR9268/203-100 / PR9268/601-000 preserve one measurement principle while using different physical constructions for their temperature classes.
PR9268/203-100 uses the standard-temperature vertical construction with an aluminum housing and a 100 °C class boundary.
PR9268/601-000 uses high-temperature materials and stainless-steel construction for the documented 200 °C sensor boundary.
Both cables are armored, but 10 m open-ended and 5 m Harting-terminated assemblies create distinct installation records.
Emerson PR9268/203-100 / PR9268/601-000 rely on gravity and internal spring forces to center the moving mass in vertical service.
Within ±30° of the vertical reference, the internal mechanism operates without additional sinking current.
Between ±30° and ±60°, the specified sinking current stabilizes the moving system at the larger angle.
Measure the actual mounting angle and confirm the monitoring circuit before treating an orientation-related low output as a sensor fault.
No. Emerson PR9268/203-100 is the standard-temperature construction, while Emerson PR9268/601-000 is the high-temperature version. Confirm the sensor-location temperature against the correct class.
Use length and termination together: Emerson PR9268/203-100 has 10 m armored cable with open ends, while Emerson PR9268/601-000 has 5 m armored cable with a Harting connector.
Check keying, bent contacts, the mating shell and cable strain on Emerson PR9268/601-000. Do not force the latch, because partial engagement can produce intermittent velocity signals.
Route Emerson PR9268/203-100 away from high-current switching conductors, support the armor without sharp bends and preserve a deliberate shield reference at the monitoring end.
A mounting angle outside the supported window, cable force on the body or missing sinking current can displace the moving system in Emerson PR9268/203-100 / PR9268/601-000. Check mechanics before recalibration.
The base beneath Emerson PR9268/203-100 / PR9268/601-000 must be rigid, clean and flat so machine motion reaches the housing without rocking. A loose or uneven base can attenuate or distort the measured vibration.