Ethernet frame
ALE111-SE1 receives or transmits subsystem data through its 10BASE-T port and configured protocol package.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa ALE111-SE1 Ethernet Communication Module |
| Item NO. | 2945402 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-26 |
10BASE-T subsystem communication for CENTUM VP
Exact suffix: standard model, explosion-protection code E and ISA Standard G3 option code 1.
Yokogawa ALE111-SE1 links CENTUM VP N-IO/FIO field control stations with a configured Ethernet subsystem. The module transfers data between the FCS communication area and that subsystem through one assigned communication function.
Through its single RJ-45 10BASE-T port, ALE111-SE1 communicates point-to-point or through a hub over a 100-ohm twisted-pair route. Builder configuration assigns one communication function to the module; multiple unrelated communication functions are not executed simultaneously by the same ALE111.
The suffix of ALE111-SE1 identifies the standard ALE111 family with explosion-protection code E and the ISA Standard G3 option. The module mounts in supported FCS or ESB node hardware, while adjacent odd/even slots can be used when an ALE111 pair is configured for redundancy.
| Technical Item | ALE111-SE1 |
|---|---|
| Brand | Yokogawa |
| Product Type | Ethernet communication module |
| Brand Country | Japan |
| System | CENTUM VP N-IO/FIO |
| Physical Interface | IEEE 802.3 10BASE-T |
| Connector | RJ-45 |
| Ports | 1 |
| Transmission | Half-duplex, 10 Mbps |
| Connection Method | Point-to-point or hub-based Ethernet |
| Maximum Segment | 100 m |
| Media Access | CSMA/CD |
| Current Consumption | 0.5 A |
| Weight | Approximately 0.30 kg |
| Dimensions | 32.8 × 130 × 125.5 mm |
The module links a configured subsystem data area with the FCS control environment through one defined Ethernet communication function.
ALE111-SE1 receives or transmits subsystem data through its 10BASE-T port and configured protocol package.
Builder settings identify the station, device area and read/write direction for each data exchange.
Received data is held in the communication input area and output data is prepared in the corresponding output image.
Control calculations read the module data or set values that ALE111-SE1 sends to the subsystem.
The hardware can support several published communication families, but each installed module is configured for one function at a time.
FA-M3, Modbus, MELSEC, YFGW, recorder-family or PLC communication is selected through the applicable software package.
Each function has its own connected-device, station-count and communication-capacity boundaries.
Two ALE111 modules in adjacent odd/even slots can operate as control and standby modules when the supported function allows it.
Module redundancy and network redundancy are separate designs; hubs, gateways and subsystem paths must match the chosen topology.
A healthy ALE111-SE1 link proves only that the Ethernet cable path is active. Check the configured communication function, station address, device mapping and the subsystem response to the intended protocol.
Before fitting ALE111-SE1 in place of another ALE111, compare the full suffix, style, unit revision, explosion-protection requirement, G3 option and FCS software compatibility. Retain the communication definitions because the front label does not encode them.
Check ALE111-SE1 against the RJ-45 wiring, 10BASE-T operation, segment length and the chosen hub or crossover point-to-point arrangement. The connected subsystem must use that same intended path.
One ALE111-SE1 receives one communication function from the builder package. Independent subsystem functions that cannot share one definition require separate communication modules.
For redundant ALE111-SE1 operation, verify odd/even slot placement, matching communication definitions, both network routes and the supported redundancy mode of the external subsystem. Installing a pair alone does not make every network redundant.
Retain the ALE111-SE1 suffix, style, unit revision, option markings and FCS slot location. Those details keep the module request tied to the correct hardware and software boundary.
Product-information support covers available manuals, data sheets, dimensional material and identification-image review. Requested files are associated with the stated manufacturer code so documentation for a neighbouring suffix is not supplied as if it described the requested item.