Establish the left-side bus direction
KJ4002X1-BA1 begins an eight-position I/O section from the left side of the carrier arrangement. Its orientation fixes the direction in which the LocalBus and following carrier hardware continue.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Emerson DeltaV KJ4002X1-BA1 Left-Side 8-Wide Carrier |
| Item NO. | 2940698 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | EMERSON |
| Brand | EMERSON |
| Creation Time | 2026-11-18 |
A left-side carrier position for DeltaV horizontal or vertical mounting arrangements.
Emerson DeltaV KJ4002X1-BA1 is a left-side eight-wide carrier for DeltaV M-series I/O. It provides the mechanical row and internal LocalBus structure for eight I/O-card and field-termination-block positions.
The word “left” in Emerson DeltaV KJ4002X1-BA1 is a functional orientation. It defines how the carrier is placed within a horizontal or vertical carrier mounting system and how the LocalBus extension continues toward the next section.
Within a DeltaV cabinet, Emerson DeltaV KJ4002X1-BA1 forms one section of a continuous carrier structure. Its connector geometry carries the LocalBus across the eight I/O positions, while extender hardware and the end terminator define how that bus continues or ends at the carrier boundary.
| Specification | KJ4002X1-BA1 |
|---|---|
| Brand | Emerson DeltaV |
| Product name | Left-side 8-wide carrier |
| System family | DeltaV M-series |
| Carrier capacity | Eight I/O positions |
| Mounting use | Horizontal or vertical carrier system |
| Orientation | Left-side record |
| Installed devices | I/O cards with field termination blocks |
| Bus relationship | Part of the DeltaV LocalBus carrier path |
| Expansion relationship | Used with LocalBus extender hardware |
| Termination requirement | End-of-bus terminators complete the final carrier boundary |
| Hazardous-area installation | Product marking, enclosure, grounding and wiring limits apply |
| Carrier identification | Left-side orientation and eight I/O positions |
The carrier operates as one element of the complete DeltaV mounting and LocalBus structure.
KJ4002X1-BA1 begins an eight-position I/O section from the left side of the carrier arrangement. Its orientation fixes the direction in which the LocalBus and following carrier hardware continue.
Each carrier position supports an I/O card and its corresponding field termination path. The mechanical row keeps those electronic and field-wiring identities aligned across all eight positions.
Extender hardware carries the LocalBus into another carrier section, while the terminator closes the final electrical endpoint. The two devices perform different roles at the boundary of the row.
Area classification and electrical limits are governed by the installed assembly and its product markings.
The product label ties carrier construction, approvals and environmental markings to one hardware record. Those markings apply to the completed installed assembly, not only to the bare metal carrier.
LocalBus electronics and field I/O wiring occupy different electrical domains on the carrier system. The termination-block arrangement maintains that separation through the module row.
KJ4002X1-BA1 is an open industrial carrier intended for a suitable enclosure. Cabinet spacing, grounding and wiring segregation complete the carrier installation.
Moore Automation can coordinate packing records for long carrier assemblies and associated modules. The shipping discussion can cover connector protection, model-label visibility, accessory separation and consolidated tracking for the final destination.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found