A direct RS232 link serves one DKC11.3-040-7-FW, or a converter / PC card changes the host connection to RS485.
Rexroth
Indramat
ECODRIVE03 · 40 A FRAME
Bosch Rexroth DKC11.3-040-7-FW ECODRIVE03 Drive Controller
Product Overview
Power & communicationBosch Rexroth Indramat DKC11.3-040-7-FW is an ECODRIVE03 drive controller with a 40 A type-current power stage and an RS232/RS485 command interface. Installed in a control cabinet, it rectifies single- or three-phase AC mains into a DC bus and switches that bus through the converter bridge to produce the three-phase A1/A2/A3 motor output.
Inside DKC11.3-040-7-FW, the charging-current limit controls the initial rise of the DC bus, the CZW capacitance stores bus energy, and the bleeder circuit provides a defined path for regenerated energy. The 040 frame exposes L+ and L− for the DC-bus connection while the motor, mains and bus conductors are organized together at X5.
Control and feedback for DKC11.3-040-7-FW are separated from the power terminals. X1 receives the 24 V control supply and control signals, X3 carries digital and analog I/O, X4 and X8 accept the two encoder paths, and X6 carries motor-temperature and holding-brake circuits. X2 supplies the serial commissioning path, while H1, S1 and the S2/S3 address switches provide front-panel diagnosis, fault clearance and addressing.
Technical Data
Exact 040 frame| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | ECODRIVE03 drive controller |
| Command interface | RS232 / RS485 at X2 |
| Mains operating mode | Single-phase or three-phase |
| Mains input voltage | 200…480 V AC ±10% |
| Mains frequency | 50…60 Hz ±2 Hz |
| Switching frequency | 4 kHz or 8 kHz, selectable |
| Type current / peak current 1 | 40 A |
| Peak current 2 at 4 kHz | 16 A |
| Peak current 2 at 8 kHz | 12.5 A |
| Continuous current 1 at 4 kHz | 13 A |
| Continuous current 2 at 4 kHz | 16 A |
| Continuous current 1 at 8 kHz | 9 A |
| Continuous current 2 at 8 kHz | 12.5 A |
| Maximum output frequency | 400 Hz at 4 kHz; 800 Hz at 8 kHz |
| DC-bus voltage | 300…800 V DC, dependent on mains input |
| Control-voltage input | 19.2…28.8 V DC |
| Control-circuit consumption | 18 W without external control-output and encoder-interface loads |
| Rated ambient boundary | +5…+45 °C; up to 1000 m installation altitude |
| Protection and installation | IP20; control-cabinet mounting |
X2 Serial Bus Topology
Commissioning pathX2 is one physical 15-pin D-sub connection that can be operated as either RS232 or RS485. The selection changes the network shape: RS232 serves one controller over a short point-to-point cable, whereas RS485 forms a multi-drive two-wire bus.
For RS485, pins 4 and 5 carry the differential pair and pin 7 is 0 V. The cable shield is bonded through the metallic connector case, and the device at the end of the bus must have termination enabled so the pair is not left electrically open.
RS485+ and RS485− carry half-duplex traffic through the shared two-wire route; 0 V establishes the reference.
The final controller closes the RS485 line with its termination switch. Intermediate devices continue the bus to the next participant.
Control, Feedback & Power Coordination
Functional organizationCommands enter before switching
Drive enable, drive halt and limit inputs arrive through X3. The control section evaluates those states together with the active parameter set before the converter bridge applies the requested motor voltage.
Encoder paths close the loop
X4 and X8 keep the two encoder inputs separate from the digital and analog I/O. The resulting position and speed data return to the controller, where they are compared with the commanded motion.
Motor conditions stay on X6
Motor-temperature monitoring and the holding-brake circuit share the X6 boundary. Their wiring remains distinct from the A1/A2/A3 motor power conductors and from the X2 commissioning interface.
Questions About DKC11.3
Six practical checks01How can the correct current frame be confirmed before wiring DKC11.3-040-7-FW?
Check that the type plate carries the complete DKC11.3-040-7-FW code. The 040 field identifies the 40 A frame; DKC11.3 is not defined for the 016 A frame, so an abbreviated “DKC11.3” reference is not enough for terminal and current checks.
02Can DKC11.3-040-7-FW share one commissioning bus with other drive controllers?
Yes. On DKC11.3-040-7-FW, X2 can operate as a two-wire, half-duplex RS485 bus with as many as 31 participants. The published bus length is up to 500 m, and the last participant must have its bus termination activated.
03Which connection is appropriate when only one DKC11.3-040-7-FW is being commissioned?
Use the RS232 mode of X2 for a direct point-to-point connection to one DKC11.3-040-7-FW. The connection supports 9600 or 19200 baud and a cable length up to 15 m.
04What should be verified at X1 before control voltage is applied to DKC11.3-040-7-FW?
Verify 19.2…28.8 V DC at X1 for DKC11.3-040-7-FW and keep ripple inside that input range. Any coupled overvoltage must be limited; the published non-repetitive ceiling is 45 V for 1 ms.
05Why do usable current values change when DKC11.3-040-7-FW is switched from 4 kHz to 8 kHz?
The switching-frequency setting changes the power-stage current boundary. DKC11.3-040-7-FW provides 16 A continuous current 2 at 4 kHz and 12.5 A at 8 kHz, so the selected frequency and the intended continuous load must be evaluated together.
06What front-panel items help identify the state and address of DKC11.3-040-7-FW?
On DKC11.3-040-7-FW, H1 is the diagnosis indicator, S1 is the fault-clearance button, and S2/S3 are address switches. X7 holds the programming module that carries firmware and parameter data.