B&R X67 system · voltage and current analog inputs
B&R X67AI1223 / X67AI1323 X67 Analog Input Modules
Model Information
B&R X67AI1223 and X67AI1323 are four-channel IP67 analog input modules for the X67 system. X67AI1223 receives differential ±10 V signals, while X67AI1323 receives differential 0–20 mA or 4–20 mA signals and transfers the converted values over X2X Link.
In X67AI1223, each M12 channel feeds a differential voltage input and 12-bit A/D converter; the high input impedance keeps the measurement load low. In X67AI1323, the current loop passes through the module input load before conversion, so loop supply, wiring polarity and the specified voltage drop must all be included in the circuit review.
Both X67AI1223 and X67AI1323 convert all four channels within 400 µs and expose configurable filtering, limit monitoring and open-circuit behavior through the module data. Their shared housing does not make the signal types interchangeable: a voltage transmitter belongs on X67AI1223, while a powered current loop belongs on X67AI1323.
Technical Specifications
| Brand | B&R |
|---|---|
| Model | X67AI1223 / X67AI1323 |
| Product Name | X67 Analog Input Modules |
| System | B&R X67 |
| Channels | 4 differential analog inputs |
| X67AI1223 Signal Range | ±10 V |
| X67AI1323 Signal Range | 0 to 20 mA or 4 to 20 mA |
| Resolution | 12-bit |
| Conversion Time | 400 µs for all channels |
| Converter Method | Successive approximation |
| X67AI1223 Input Impedance | 20 MΩ |
| X67AI1223 Maximum Input | ±30 V |
| X67AI1323 Input Load | <300 Ω |
| X67AI1323 Maximum Input | ±30 mA |
| X67AI1323 Voltage Drop | 4.5 V |
| Channel-to-Bus Isolation | 500 Veff |
| X2X Link Connection | M12, B-coded |
| Analog Connections | 4 × M12, A-coded |
| Supply Connections | M8 |
| Nominal Supply | 24 VDC |
| Supply Range | 18 to 30 VDC |
| Sensor Supply Capacity | 0.5 A maximum; 12 W maximum |
| Degree of Protection | IP67 |
| Operating Temperature | -25 to 60°C |
| Dimensions | 53 × 85 × 42 mm |
| Approximate Weight | X67AI1223: 200 g; X67AI1323: 190 g |
Analog Conversion Path
Voltage and current reach the same 12-bit process-data format through separate front-end circuits and channel wiring paths.
X67AI1223 measures the potential difference at each differential pair. High input impedance reduces loading, but common-mode and maximum input boundaries still apply.
X67AI1323 inserts its input load into the loop. Transmitter supply must cover the module voltage drop plus the remaining devices and cable resistance.
All four channels are converted inside the stated 400 µs interval, giving the controller one defined update relationship across the module.
Channel Evaluation
Module parameters determine how raw conversion results become stable process values and how wiring conditions are reported.
Configured filtering smooths the converted signal after the electrical input stage. It cannot correct a loop with inadequate supply or a voltage channel beyond common mode.
Upper and lower thresholds can turn the measured value into a channel status without replacing the analog process value used by the application.
Current-loop wiring faults are evaluated differently from voltage-input conditions. Diagnostics therefore must be interpreted for X67AI1323 or X67AI1223, not for the shared enclosure.
Common Product Questions
How can X67AI1223 and X67AI1323 be distinguished before wiring?+
Why does X67AI1323 read low when the transmitter is powered?+
What should be checked when X67AI1223 is saturated?+
Can the same software scaling be copied between X67AI1223 and X67AI1323?+
How should noisy values on X67AI1223 or X67AI1323 be investigated?+
What belongs in an enquiry for X67AI1223 or X67AI1323?+