Cyclic command and status exchange stays on the fieldbus interface of DKC03.3-100-7-FW.
Rexroth
Indramat
ECODRIVE03 · 100 A POWER FRAME
Bosch Rexroth DKC03.3-100-7-FW ECODRIVE03 PROFIBUS-DP Drive Controller
Product Summary
PROFIBUS-DPBosch Rexroth Indramat DKC03.3-100-7-FW is a 100 A ECODRIVE03 drive controller with PROFIBUS-DP command communication. The cabinet-mounted device combines the mains rectifier, DC-link charging circuit, DC-bus capacitor, motor inverter and digital control electronics, so it converts the incoming AC supply into a controlled three-phase output while exchanging cyclic commands with the higher-level controller.
Inside DKC03.3-100-7-FW, single- or three-phase 200…480 V AC enters the mains section and charges the 300…800 V DC bus through a current-limiting path before the inverter is enabled. The inverter switches that stored energy to A1, A2 and A3; regenerated motor energy returns to the same bus and can be routed through the bleeder and dynamic-braking circuit.
The signal connections of DKC03.3-100-7-FW remain separate from the power path. PROFIBUS-DP carries command and status data, X2 provides RS232/RS485 parameterization and diagnosis, X4 and X8 accept measuring-system signals, and X3 groups digital and analog control signals. This division keeps network communication, encoder feedback and high-voltage motor wiring on distinct connection boundaries.
Specification Details
18 verified rows| Brand | Bosch Rexroth Indramat |
|---|---|
| Product name | ECODRIVE03 PROFIBUS-DP drive controller |
| Command interface | PROFIBUS-DP |
| Mains operating mode | Single-phase or three-phase |
| Mains input voltage | 200…480 V AC ±10% |
| Mains frequency | 50…60 Hz ±2 Hz |
| Switching frequency | 4 kHz or 8 kHz |
| Type current / peak current 1 | 100 A |
| Peak current 2 at 4 / 8 kHz | 40 A / 32 A |
| Continuous current 1 at 4 / 8 kHz | 32 A / 21 A |
| Continuous current 2 at 4 / 8 kHz | 40 A / 32 A |
| Maximum output frequency | 400 Hz at 4 kHz; 800 Hz at 8 kHz |
| Power dissipation at continuous current 2 | 420 W |
| DC-bus voltage / capacitance | 300…800 V DC / 0.675 mF ±20% |
| Control-voltage input | 19.2…28.8 V DC |
| Control-circuit consumption | 25 W |
| Rated ambient boundary | +5…+45 °C; up to 1000 m |
| Protection / mounting | IP20 / control cabinet |
PROFIBUS-DP Command Flow and Local Service Access
Communication rolesThe PROFIBUS-DP interface of DKC03.3-100-7-FW receives cyclic command values from the automation controller and returns drive status through the same fieldbus participant. Bus addressing and the fieldbus cable therefore belong to the command path rather than to the motor-feedback circuit.
Parameterization and diagnosis use a second route. X2 on DKC03.3-100-7-FW provides RS232/RS485 service communication, allowing local access without treating that serial connection as the cyclic PROFIBUS-DP command channel.
RS232/RS485 carries commissioning and diagnostic communication independently of the command bus.
Measuring-system signals return motor position information directly to the drive electronics rather than through PROFIBUS-DP.
DC-Link Charging, Motor Output and Regenerated Energy
Power sequenceThe power section of DKC03.3-100-7-FW manages incoming mains energy, DC-link storage and motor switching as one coordinated path.
Current-limited DC-link rise
The rectifier charges the DC bus through a limiting circuit before DKC03.3-100-7-FW releases the inverter for normal operation.
Stored DC becomes three-phase motor power
The inverter converts the 300…800 V bus into the controlled A1/A2/A3 motor output; the selected 4 or 8 kHz switching frequency changes the allowed current boundary.
Regenerated energy returns to the common link
Motor braking energy flows back to the DC bus, where the capacitance and bleeder/dynamic-braking path of DKC03.3-100-7-FW handle the returned energy.
Questions & Answers
06 practical checks01Which command cable belongs to DKC03.3-100-7-FW?
Use the PROFIBUS-DP connection specified for DKC03.3-100-7-FW; X2 is the separate RS232/RS485 service route and does not replace the cyclic fieldbus link.
02Why does the 100 A code on DKC03.3-100-7-FW not equal every continuous-current value?
The 100 A field identifies the type-current and first peak-current class of DKC03.3-100-7-FW; continuous current depends on the published current definition and whether 4 or 8 kHz switching is selected.
03What must be checked before changing DKC03.3-100-7-FW to 8 kHz?
For DKC03.3-100-7-FW, verify that the required motor current remains within the lower 8 kHz peak and continuous-current limits before changing the switching frequency.
04Where should the motor measuring system connect on DKC03.3-100-7-FW?
The measuring-system inputs of DKC03.3-100-7-FW are X4 and X8; encoder feedback must not be routed through the PROFIBUS-DP or X2 service connectors.
05How is the control supply separated from the power circuit on DKC03.3-100-7-FW?
DKC03.3-100-7-FW accepts 19.2…28.8 V DC for control electronics while L+/L− carry the high-voltage DC bus and A1/A2/A3 carry motor power.
06Which enclosure boundary applies to DKC03.3-100-7-FW?
DKC03.3-100-7-FW is an IP20 control-cabinet device; rated data applies from +5 to +45 °C and up to 1000 m installation elevation.