Rectifier and DC bus
Three-phase mains enters the rectifier of 8EI013HWS10.0600-1 and charges the internal DC bus. That stored DC energy is the source used by the inverter rather than a direct feed from the mains terminals to the motor.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | B&R Industrial Automation 8EI013HWS10.0600-1 ACOPOS P3 Single-Axis Servo Drive |
| Item NO. | 2944887 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | B&R |
| Brand | B&R |
| Creation Time | 2026-11-25 |
B&R Industrial Automation 8EI013HWS10.0600-1 is an ACOPOS P3 wall-mounted single-axis servo drive. It combines the mains rectifier, DC bus, motor inverter and control electronics in one 8EI module, so its system responsibility is to convert the incoming three-phase supply into one regulated motor output while exchanging commands and status over POWERLINK.
Power entering 8EI013HWS10.0600-1 is rectified into a 940 µF DC bus that supplies the inverter stage. The motor connection carries the three-phase output together with protective earth and the motor-temperature path, while the separate 24 VDC input powers control electronics and the holding-brake circuit rather than the motor power stage.
The feedback path of 8EI013HWS10.0600-1 is assigned through its configurable digital multi-encoder interface, and enable and trigger signals enter through the low-voltage control connectors. The housing is installed vertically so cooling air can travel from the lower inlet to the upper outlet, with the published free space retained above and below the module.
| Attribute | 8EI013HWS10.0600-1 |
|---|---|
| Brand | B&R Industrial Automation |
| Product Type | ACOPOS P3 single-axis servo drive |
| Brand Country | Austria |
| Mains input | 3 × 200 to 480 VAC ±10% |
| Installed load | Maximum 13.5 kVA |
| DC-bus continuous power | 6.5 kW |
| DC-bus capacitance | 940 µF |
| Control supply | 24 VDC ±25% |
| Motor output current | 13 A continuous; 32.5 A peak |
| Switching frequencies | 5, 10 or 20 kHz; 5 kHz nominal |
| Network interface | POWERLINK V2 managing or controlled node |
| Encoder interface | Configurable digital multi-encoder interface |
| Dimensions | 66 × 374 × 258.5 mm |
| Weight / protection | 4 kg / IP20 |
The power section of 8EI013HWS10.0600-1 keeps the high-energy path separate from the 24 V control path while both converge at the inverter control stage.
Control supply boundary — The separate 24 VDC input of 8EI013HWS10.0600-1 maintains the electronics and brake-control path. This prevents the logic supply from being treated as part of the motor-power rating.
Three-phase mains enters the rectifier of 8EI013HWS10.0600-1 and charges the internal DC bus. That stored DC energy is the source used by the inverter rather than a direct feed from the mains terminals to the motor.
The inverter in 8EI013HWS10.0600-1 switches the DC bus into a controlled three-phase motor output. Protective earth, brake and temperature connections remain identifiable at their assigned terminals.
Motion commands only form a closed control loop when 8EI013HWS10.0600-1 receives both an enable state and valid motor feedback.
The configured encoder interface returns position and speed information to 8EI013HWS10.0600-1, allowing its controller to compare measured motion with the commanded axis state.
Enable and trigger signals enter through the low-voltage connector field of 8EI013HWS10.0600-1. Their common reference must be wired as shown for a defined signal potential.
The brake output of 8EI013HWS10.0600-1 is supplied from the 24 V control input. It is a separate actuator path and does not carry the inverter’s three-phase motor current.
The motor-temperature connection of 8EI013HWS10.0600-1 returns a separate thermal state beside encoder position data, so a temperature trip can be distinguished from loss of feedback or enable.
Record the complete 8EI013HWS10.0600-1 type plate, the configured interface code and the terminal arrangement. The full suffix must stay with the record because the base 8EI013 frame does not identify the fitted communication and encoder configuration.
Check that the configured encoder type and the physical feedback connector on 8EI013HWS10.0600-1 describe the same motor system. Then separate an encoder-data fault from an enable or motor-power fault by reviewing feedback status before energizing the inverter stage.
The 24 V input of 8EI013HWS10.0600-1 supplies control electronics and the motor holding-brake path, not the inverter output. Size it from the control consumption plus the connected brake current and keep the motor-power calculation on the mains/DC-bus side.
Control voltage can start the electronics of 8EI013HWS10.0600-1 while mains power, enable state or valid encoder feedback is still absent. Review those three paths independently before treating the condition as a failed power stage.
Keep at least the published 80 mm air space above and below 8EI013HWS10.0600-1, then add the extra space required for the display module and cable bend radii. The vertical air path must remain open because cooling air leaves at the top of the housing.
Confirm the brake voltage and current against the motor brake and include that current in the 24 V supply calculation for 8EI013HWS10.0600-1. The brake conductors must remain on the assigned brake terminals rather than being combined with the motor phases.
Moore Automation keeps each industrial automation enquiry under the complete manufacturer and model code. Type-plate images, requested documentation and configuration notes remain attached to the same record so nearby drive variants are not merged.
A named account contact coordinates quotation details, lead-time information and shipment updates for the enquiry.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found