Expanded memory, nodes and integrated motion
Allen-Bradley 5069-L350ERM High-capacity CompactLogix 5380 Motion Controller
5 MB memory, 31 local I/O modules, 120 nodes and 24 drive axes.
Product Description
At the upper end of the CompactLogix 5380 motion range, the Allen-Bradley 5069-L350ERM provides 5 MB user memory and capacity for 24 integrated motion drive axes.
A local bank can include up to 31 Compact 5000 I/O modules, while the EtherNet/IP configuration can reach 120 nodes. Dual 1 Gb ports support linear, DLR and Dual-IP arrangements for machine and plant connectivity.
The larger 5069-L350ERM capacity does not remove the need for node, connection, task and network-load planning; each limit must be checked against the actual project architecture.
Technical Specifications
| Technical Item | 5069-L350ERM |
|---|---|
| Brand | Allen-Bradley |
| Product Type | High-capacity CompactLogix 5380 motion controller |
| Brand Country | United States |
| User Memory | 5 MB |
| Local I/O Modules | 31 maximum |
| EtherNet/IP Nodes | 120 maximum |
| Integrated Motion Axes | 24 drive axes |
| Ethernet Ports | 2 × 10/100/1000 Mb/s |
| MOD Power | 18…32 V DC; 450 mA maximum |
| Inrush Current | 850 mA for 125 ms |
| Power Dissipation | 8.5 W maximum |
| Thermal Dissipation | 29 BTU/hr maximum |
| Weight | 0.768 kg |
High-capacity Motion Coordination
Scale motion without losing the network budget
- The 24-axis allowance applies to integrated motion drive axes configured to the controller.
- Reserve network bandwidth and node count for every drive, adapter and supervisory device instead of sizing only by axis total.
- Use synchronized EtherNet/IP design for coordinated groups and validate requested update rates before commissioning.
- Partition programs, motion groups and diagnostic routines within the 5 MB user-memory boundary.
Memory, Node & I/O Scale
Balance three independent capacity ceilings
- Up to 31 local I/O modules can sit in the controller bank, but distributed adapters add to the 120-node EtherNet/IP limit.
- The 5 MB memory figure covers application content and should include margin for online edits, tags and future sequences.
- Network topology diagrams show how controllers, drives, HMIs and I/O adapters can share linear or ring paths.
- A project is only within capacity when memory, local modules, nodes and motion axes all remain inside their own limits.
Frequently Asked Questions
Why does a 5069-L350ERM project reach a limit before all 120 network nodes are used?
Memory, connections, local I/O and motion axes are separate resources, so any one can become the first constraint. Review the controller properties and project statistics instead of using the node count as a universal capacity figure.
Can 5069-L350ERM coordinate 24 axes through ordinary unmanaged switches?
The axis count does not guarantee suitable timing through every network design. Validate time synchronization, switch behavior, requested packet intervals and the complete traffic path for the motion application.
How should 31 local modules on 5069-L350ERM be powered?
Calculate MOD and SA demand for the controller and every module segment, including inrush and field loads. Use the required power-distribution modules when the bank must be segmented rather than feeding the entire row from an undersized source.
Does Dual-IP on 5069-L350ERM double the 120-node controller limit?
No; Dual-IP separates network identities and traffic paths but does not create a second controller capacity allocation. Count all configured EtherNet/IP nodes against the controller limit.
Why is extra memory margin important on 5069-L350ERM even when the initial project downloads?
Online edits, added tags, trends and future machine sequences consume memory after initial commissioning. Leave deliberate headroom so a maintenance change does not force an unplanned controller redesign.
Which checks matter before replacing a smaller 5380 controller with 5069-L350ERM?
Confirm firmware and project compatibility, module-bank arrangement, power, Ethernet mode and panel space before migration. The larger capacity does not automatically preserve every port setting or physical installation detail from the previous catalog.
Broad Automation Coverage
Moore Automation
One source for current and hard-to-find parts
Moore Automation supports PLC, DCS, TSI, HMI, drive, sensor and control-system enquiries. The sourcing scope includes current catalogs and discontinued components used in maintenance inventories.
Send the complete part number and quantity so the requested variant remains clear from enquiry through quotation.
Recommended Products
- Herion 0820171
- Keyence OP-88240
- Parker NQ41154559
- Phoenix Contact 2727349
- Yaskawa CIMR-P5C4030
- CAREL EVD0000UC0
- Krones GA240.Z15
- Danfoss FC-102P30KT4E21H1XGXXXXSXXXXA0BXCXXXXD0
- Lapp 1119251
- Murr 7000-74041-0000000
- Notifier M710
- Roemheld 1891201
- Aventics 0821302561
- Siemens 3RN1010-1CB00
- ABB 1SAM350000R1007
- Allen-Bradley 700-CF220KF
- Honeywell HTE200B20C2
- Festo DGPL-63-1150PPVA-GFB
- Schneider ABE7-H16S43
- WAGO 750-468
- B&R 8BVP0880HC00.000-1
- Beckhoff KL3202
- Rexroth M4-4047-20/3M4-15VZW21SXV01
- GE IC200MDL650C
- Lenze MCA19S35-SRMP5
- Legrand 572262A
- Brady 42101
- ifm O4E500
- SEW DRN132M4/TH/EG7C/V
- SMC XYA-25AH0
- SICK ISD300-1112
- Weidmüller 1918910000
- Baumüller BUM62T-100/130-54-M-024
- Bosch 0510725323
- Indramat MAC112D-0-FD-3-C/130-A-2/S013
- KEB 09.F5.MDD.Y0P0
- Omron FH-1050-H
- Eaton P3-63/I4/MBS/SVB-SW/HI11
- Finder 58.32.9.024.0050
- Herion 0819250
- Keyence IT2-01
- Parker RDM2AT35SV10
- Phoenix Contact 2727941
- Yaskawa SGMGH-30Q5A6C
- CAREL CONVONOFF0
- Krones 5-745-96-002-2
- Danfoss FC-302P30KT5E21H1XGXXXXSXXXXA0BXCXXXXDX
- Siemens QAE2120.010
- ABB 1SAZ331201R1005
- Allen-Bradley 160S-AA02NPS1
- Honeywell EXB-1
- Festo EGC-HD-160-1700-TB-0H-GK-KL
- Schneider NSYCR100WU2C
- WAGO 750-466
- B&R 5MP050.0653-01
- Beckhoff KL1104
- Rexroth MAF100C-0100-FR-S6-KGO-05-N1
- GE RB4U
- Lenze MDSKABS11222
- Legrand 077662L
Contact Us