Allen-Bradley 2198-D020-ERS4 / 2198-D057-ERS4 Kinetix 5700 High-current Dual-axis Advanced-safety Inverters

Allen-Bradley 2198-D020-ERS4 / 2198-D057-ERS4 Kinetix 5700 High-current Dual-axis Advanced-safety Inverters Item NO.: 2911891

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 2198-D020-ERS4 / 2198-D057-ERS4 Kinetix 5700 High-current Dual-axis Advanced-safety Inverters
Item NO. 2911891
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-09-30

Allen-Bradley 2198-D020-ERS4 / 2198-D057-ERS4 Kinetix 5700 High-current Dual-axis Advanced-safety Inverters
Allen-Bradley · 5700Kinetix 5700 High-current Dual-axis Advanced-safety Inverters

Allen-Bradley 2198-D020-ERS4 / 2198-D057-ERS4 Kinetix 5700 High-current Dual-axis Advanced-safety Inverters

2 × 8 / 23 A continuous20 / 57.5 A peak classAdaptive tuning and diagnostics

Product Description

The Allen-Bradley 2198-D020-ERS4 / 2198-D057-ERS4 combination compares two higher-current Kinetix 5700 dual-axis advanced-safety inverters. The D020 supplies 8 A rms continuous per axis with a 20 A peak class, whereas the D057 raises each channel to 23 A rms continuous and 57.5 A peak; both retain two independently controlled motor outputs in one module.

A common Kinetix 5700 dc bus feeds 2198-D020-ERS4 / 2198-D057-ERS4, and 24 V control power supports electronics, feedback processing, network communication and status. Axis commands and diagnostics enter over EtherNet/IP, adaptive tuning operates on the configured motor and load response, and the ERS4 safety connection supervises advanced safety functions independently of the normal motion program.

Technical Specifications

Technical Item 2198-D020-ERS4 2198-D057-ERS4
Brand Allen-Bradley Allen-Bradley
Product Type Kinetix 5700 dual-axis advanced-safety inverter Kinetix 5700 dual-axis advanced-safety inverter
Axes per Module 2 2
Continuous Output Current per Axis 8 A rms 23 A rms
Peak Output Current per Axis 20 A rms class 57.5 A rms
Continuous Output — Zero to Peak 11.3 A class 32.5 A
Peak Output — Zero to Peak 28.3 A class 81.3 A
Continuous Output Power Mid-current dual-axis rating 15.9 kW
DC-bus Input Current Matched to combined axis duty 24.5 A
Bus Capacitance Kinetix 5700 internal bus capacitor 705 µF
24 V Control Current Dual-axis control load 8.3 A
Power Dissipation at Rated Output Rating-specific 660 W at 100%
Velocity-loop Bandwidth Up to 400 Hz Up to 400 Hz
PWM Frequency 4 kHz 4 kHz
Approximate Dimensions 267.5 × 358 × 55 mm class 267.5 × 358 × 55 mm
Approximate Weight Rating-specific 6.76 kg
Safety Advanced integrated safety, ERS4 Advanced integrated safety, ERS4
Enclosure IP20 open type IP20 open type

Higher-Current Axis Coordination

2198-D020-ERS4 / 2198-D057-ERS4 coordinate two motor channels whose simultaneous acceleration, regeneration and thermal duty all load the same module and dc bus.

Continuous-versus-peak choice

The 8/20 A and 23/57.5 A current steps must be checked against motor continuous torque, acceleration current and the duration of repeated peaks.

Combined bus demand

Two axes can draw or return energy at once, so the power-supply and capacitor system is sized from the overlapping motion cycle rather than either motor alone.

Channel-specific cabling

Each motor and feedback pair stays on its assigned A or B interface; swapping only one side creates feedback-to-power mismatches during commissioning.

Adaptive Tuning and Fault Response

The control and diagnostic functions of 2198-D020-ERS4 / 2198-D057-ERS4 use measured motor response and axis-specific status to separate load behavior from wiring or safety faults.

Load-observer adjustment

Adaptive tuning can compensate for load inertia and resonant behavior after the correct motor feedback and mechanical system are identified.

Fault localization

Axis codes distinguish feedback loss, motor-power conditions, following error and common bus events, guiding checks to one channel or the shared supply.

Thermal coordination

Current limits, module temperature and duty-cycle data work together; a repeated thermal trip requires review of both axes and enclosure cooling.

Frequently Asked Questions

How is 2198-D020-ERS4 / 2198-D057-ERS4 selected when both axes accelerate together?

Sum the time-aligned power and dc-bus demand of both motion profiles, then check continuous, peak and regeneration limits. Selecting only from each motor’s standalone current can undersize the shared system.

Why does 2198-D020-ERS4 / 2198-D057-ERS4 report a bus fault on both axes?

The two inverters share the dc-bus connection, so a supply, precharge, overvoltage or regenerative-energy event can appear as a common condition. Inspect the power-supply and shunt path before troubleshooting both motors independently.

What should be compared before moving between 2198-D020-ERS4 / 2198-D057-ERS4?

Compare current, power, dc-bus demand, heat loss, conductor requirements and physical module data. The controller and safety project must also use the replacement catalog number and validated configuration.

Can adaptive tuning fix incorrect feedback wiring on 2198-D020-ERS4 / 2198-D057-ERS4?

No. Tuning assumes correct motor identity, phase wiring and feedback polarity. Resolve wiring and commutation faults before using observer or bandwidth adjustments.

Why can 2198-D020-ERS4 / 2198-D057-ERS4 overheat below its peak current?

Peak current is time-limited and does not define continuous thermal capacity. Repeated acceleration on two axes, high ambient temperature or restricted airflow can exceed the module’s average loss limit.

How are safety and motion faults separated on 2198-D020-ERS4 / 2198-D057-ERS4?

Read the axis fault, safety connection status and controller safety diagnostics together. A safety demand can correctly remove torque even when feedback, network link and normal motion configuration remain healthy.

Customer Support

www.mvme.cn

Technical questions remain linked to the order

A dedicated Moore Automation contact coordinates suffix checking, quantity, quotation changes and dispatch updates from one traceable enquiry.

Model clarification

Close catalog numbers are separated.

Quotation control

Revisions keep the same reference.

Packing review

Fragile parts receive route-aware packing.

Tracking updates

Shipment details are shared promptly.

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.