Allen-Bradley 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 analog signal follower drives

Allen-Bradley 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 analog signal follower drives Item NO.: 2913743

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Allen-Bradley 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 analog signal follower drives
Item NO. 2913743
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category AB
Brand ALLEN-BRADLEY
Creation Time 2026-10-09

Allen-Bradley 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 analog signal follower drives

160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1Allen-Bradley analog signal follower drives

Bulletin 160 Series C SSC · exact-model technical comparison

Product Summary

Covering the larger 460 V-class Bulletin 160 SSC steps, Allen-Bradley 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 are analog signal follower drives for 1.5, 2.2, and 3.7 kW motor outputs. The SF1 interface supplies the speed command to the regulator, while the converter and inverter stages deliver adjustable-frequency power to the motor.

As output capacity rises across 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1, heat dissipation, weight, and frame size no longer remain identical; BA10 uses the larger power frame. Control wiring still follows the same analog-and-digital terminal concept, so model-specific thermal and power hardware must not be inferred from the shared front-panel layout.

Technical Details

Technical Item160-BA04NSF1160-BA06NSF1160-BA10NSF1
Brand Allen-Bradley
Product Type Bulletin 160 SSC variable-speed drive
Product Family 160 Series C
Input Voltage 380…460 V AC, three-phase
Interface Option SF1 analog signal follower
Motor Output 1.5 kW (2 hp) 2.2 kW (3 hp) 3.7 kW (5 hp)
Output Current 4.0 A 6.0 A 10.5 A
Maximum Heat Dissipation 50 W 77 W 120 W
Approximate Weight 1.02 kg 1.10 kg 2.37 kg
Output Frequency 0…240 Hz
Drive Efficiency 97.5%
Enclosure IP20 open type
Cooling Natural convection; fan on larger frames where specified
Operating Temperature 0…50 °C
Relative Humidity 0…95%, noncondensing
Altitude 1000 m without derating
Digital Inputs Three programmable inputs plus start/stop control
Analog Command 0…10 V DC or 4…20 mA

Diagnostics and Protection — Thermal and Fault Logic

160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 monitor both the electrical power path and the configured motor relationship.

160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1Current · Voltage · Temperature
01

Overload supervision

Measured motor current is evaluated against programmed protection settings over time.

Current
02

Bus and line faults

The controller blocks output when supply or DC-bus conditions leave the permitted operating window.

Voltage
03

Drive thermal state

Internal thermal supervision reacts when load, ambient conditions, or airflow raise the drive temperature excessively.

Temperature

Installation Highlights — Fan-Cooled Power Frames

The physical progression of 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 affects panel spacing and heat removal.

Frame

BA10 size transition

The highest model uses a larger enclosure footprint, so mounting holes and clearance are not copied from smaller drives.

Airflow

Unobstructed cooling path

Required vertical space and clean airflow allow internally generated heat to leave the drive.

Routing

Power and signal separation

Motor and line conductors stay apart from the SF1 analog reference and programmable-input wiring.

Setup and Operation Questions

Why must 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 receive separate dimensional checks?
160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 do not all share one frame; BA10 has greater capacity, heat loss, weight, and dimensions, so mounting must be checked from its own column.
What is the fastest way to diagnose no response to an analog signal on 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1?
Measure the reference at the SF1 terminals of 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1, verify voltage/current mode and common, then check run logic and frequency limits.
Why can 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 fault after a panel fan fails?
Loss of panel airflow raises the ambient air surrounding 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 and reduces heat removal, which can activate thermal protection under load.
How should motor and reference cables cross near 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1?
Keep the cables separated around 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1; when a crossing is unavoidable, use a right-angle crossing instead of a long parallel run.
What must be reviewed before increasing motor size on 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1?
Recheck output current, motor voltage, overload demand, branch protection, conductors, enclosure heat, and mechanical load before moving among 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1.
Which records should accompany a spare 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1?
Store the complete 160-BA04NSF1 / 160-BA06NSF1 / 160-BA10NSF1 model with parameter values, terminal map, motor data, protection sizes, and the intended panel location.

About Moore Automation

MOORE AUTOMATION

https://www.mvme.cn/

Moore Automation supplies industrial automation components and supports international customers with model-focused quotation and dispatch coordination.