Duplexed processors
S2SC70D-SA11010 / S2SC70D-SA12010 contain two identical S2CP471 modules. The duplicated processor arrangement belongs to the safety control unit itself, rather than to an external node.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa S2SC70D-SA11010 / S2SC70D-SA12010 Duplexed Safety Control Units |
| Item NO. | 2932315 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-13 |
Yokogawa S2SC70D-SA11010 / S2SC70D-SA12010 are duplexed safety control units for ProSafe-RS, combining safety control processing, dual Vnet/IP communication and interfaces for N-IO and supported FIO nodes in a rack-mounted unit. Their control structure supports SIL3 safety functions while keeping processor and power redundancy inside the same chassis.
S2SC70D-SA11010 / S2SC70D-SA12010 each use two identical S2CP471 processor modules and two power supply modules. Application programs are retained in flash memory and operating data is held in nonvolatile memory, so the processor pair and memory structure serve different parts of the control cycle rather than acting as interchangeable storage.
The functional layout of S2SC70D-SA11010 / S2SC70D-SA12010 is the same, but the incoming AC branch differs. S2SC70D-SA11010 is the 100–120 V AC construction and S2SC70D-SA12010 is the 220–240 V AC construction; the cabinet feed and its protective devices must therefore follow the complete order code.
| Specification | S2SC70D-SA11010 | S2SC70D-SA12010 |
|---|---|---|
| Brand | Yokogawa | |
| Product type | Duplexed safety control unit | |
| Control system | ProSafe-RS | |
| Safety integrity | SIL3 | |
| Processor configuration | Two S2CP471 modules | |
| Network | Dual Vnet/IP | |
| Power input | 100–120 V AC | 220–240 V AC |
| Power consumption | 200 VA | 230 VA |
| Power modules | Two | |
| Maximum N-IO nodes | 32 | |
| Maximum safety nodes | 13 | |
| Maximum FIO modules | 8 | |
| Standard ambient range | −20 to 40 °C | |
| Approximate weight | 8.5 kg | |
| Coating | G3 | |
S2SC70D-SA11010 / S2SC70D-SA12010 organize safety execution around a matched processor pair and two different forms of retained information. This keeps the application definition distinct from changing operational data.
S2SC70D-SA11010 / S2SC70D-SA12010 contain two identical S2CP471 modules. The duplicated processor arrangement belongs to the safety control unit itself, rather than to an external node.
S2SC70D-SA11010 / S2SC70D-SA12010 retain application programs in flash memory. The program image defines the safety logic executed by the processor pair.
S2SC70D-SA11010 / S2SC70D-SA12010 use nonvolatile memory for operating data. This storage path is separate from the flash location used for the application program.
Through dual Vnet/IP and its node interfaces, S2SC70D-SA11010 / S2SC70D-SA12010 connect the safety controller to the wider system and to field I/O at different hierarchy levels.
S2SC70D-SA11010 / S2SC70D-SA12010 use dual Vnet/IP for control-network communication. Both paths belong to the specified duplexed network construction.
S2SC70D-SA11010 / S2SC70D-SA12010 can address up to 32 N-IO nodes. These nodes extend field-signal connectivity beyond the controller rack.
S2SC70D-SA11010 / S2SC70D-SA12010 support up to eight FIO modules and up to thirteen safety nodes, making those limits separate from the larger N-IO node count.
S2SC70D-SA11010 / S2SC70D-SA12010 use different AC inputs: the first is 100–120 V AC and the second is 220–240 V AC. The full code keeps that cabinet-power distinction visible.
No. S2SC70D-SA11010 / S2SC70D-SA12010 are duplexed safety control units and each uses two identical S2CP471 processor modules.
S2SC70D-SA11010 / S2SC70D-SA12010 store application programs in flash memory and retain operating data in nonvolatile memory; these are distinct storage roles.
No. S2SC70D-SA11010 / S2SC70D-SA12010 specify separate architectural limits: up to 32 N-IO nodes, up to 13 safety nodes and up to 8 supported FIO modules.
For S2SC70D-SA11010 / S2SC70D-SA12010, identify both Vnet/IP paths, the selected N-IO/FIO node layout, the AC feed and the protective grounding points.
An S2SC70D-SA11010 / S2SC70D-SA12010 enquiry should retain the exact voltage code, processor configuration, network arrangement, coating selection and required quantity.
https://www.mvme.cn
Moore Automation prepares automation parts for dispatch with model labels and protective packing suited to the item. Carrier details and the available tracking reference are linked to the shipment record after collection.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found