Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa S2MMM843-SS1130 N-IO Analog Digital I/O Module
Yokogawa S2MMM843-SS1130 N-IO Analog Digital I/O Module

Yokogawa S2MMM843-SS1130 N-IO Analog Digital I/O Module Item NO.: 2932029

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa S2MMM843-SS1130 N-IO Analog Digital I/O Module
Item NO. 2932029
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-12

Yokogawa S2MMM843-SS1130 | N-IO Analog Digital I/O Module
Yokogawa · ProSafe-RS N-IO

Yokogawa S2MMM843-SS1130 N-IO Analog Digital I/O Module

Exact model and suffix configuration
01

Product Information

Yokogawa S2MMM843-SS1130 is a 16-channel, module-isolated N-IO module for the ProSafe-RS safety control system. It connects mixed field signals to the N-IO node by assigning analog input, analog output, digital input or digital output operation separately to each channel.

Within Yokogawa S2MMM843-SS1130, the SS1130 selection combines standard analog and digital functions with the explosion-protection and ISA G3 wide-temperature options. No more than eight channels operate as analog outputs, while the other channel positions remain available for the supported input or discrete functions.

Yokogawa S2MMM843-SS1130 carries HART communication on channels configured for current input or output. System power feeds the N-IO electronics, and the external 24 V DC field supply feeds connected loops and output loads; a floating field supply preserves the documented separation between system and field ground.

02

Product Specifications

Brand Yokogawa
Model S2MMM843-SS1130
Product Name N-IO Analog Digital I/O Module
Country Japan (manufacturer)
Channel Count 16, module isolated
Selectable Functions AI, AO, DI or DO per channel
Maximum Analog Outputs 8 channels
Analog Current Range 4 to 20 mA
HART Support Revision 7.3; HART 5, 6 and 7 devices connectable
System Power Consumption 600 mA at 24 V DC maximum condition
Field Power Capacity 11 A at 24 V DC maximum condition
Field Supply Range 24 V DC, -10% / +20%
Withstanding Voltage 1500 V AC for 1 minute between I/O and system
Net Weight Approx. 0.64 kg
Software Baseline ProSafe-RS R4.01 or later
03

Flexible Channel Assignment

S2MMM843-SS1130 turns one 16-point N-IO position into a controlled mix of current and discrete functions, but the channel plan must be completed before wiring and power sizing are approved.

Define every channel role

Assign AI, AO, DI or DO to each S2MMM843-SS1130 point in the engineering record before terminal schedules are issued. This keeps cabinet drawings, software tags and commissioning sheets aligned.

Analog output is limited to eight channels, so a proposed mix must be checked against that ceiling instead of assuming all sixteen positions can source 4-20 mA.

Separate signal behaviours

Current input and current output use 40 ms data updates, while discrete input and output paths update in 10 ms. Control logic should not treat those paths as having identical timing.

For analog input, the two-wire or four-wire choice is set per channel. For digital input, dry-contact resistance and the documented response window determine reliable state recognition.

Preserve redundancy intent

A pair of S2MMM843 modules can be installed in a dual-redundant arrangement, but both sides need the same channel assignment, field termination and engineering definition.

Replacement work should compare the full S2MMM843-SS1130 suffix, software release and base-plate position before a spare is accepted as the standby mate.

04

Power and Diagnostic Boundaries

The mixed-function freedom of S2MMM843-SS1130 moves several design decisions into the power, grounding and field-diagnostic plan.

Size field power from the loads

The 11 A field-power figure represents a maximum digital-output loading condition, not a fixed normal draw. Calculate the actual supply from channel modes, connected loads and expected inrush current.

A floating field supply gives the documented isolation and improved noise immunity. Grounding the field supply connects functional system ground to field ground and changes that isolation condition.

Apply the correct line diagnostics

SCB100 and SCB110 elements are used in different series or parallel positions according to whether a digital input is normally off or normally on. Their polarity and placement belong in the loop drawing.

For analog output, configurable open- and short-circuit detection limits should match the intended load range so a valid loop is not reported as a fault.

Check high-current DO use

A single digital output is rated up to 0.66 A; adjacent channels may be paralleled for documented 1.3 A or 2.0 A arrangements through the external terminal board.

Temperature derating still limits the total module load. Parallel channels therefore require both the individual wiring check and a module-wide current calculation.

05

Questions & Answers

01How should a mixed-signal replacement be prepared for S2MMM843-SS1130?+

For S2MMM843-SS1130, export the existing channel-mode list, HART assignments, base-plate position and redundancy role before removal; restore that exact map and then verify each field loop independently.

02Why can S2MMM843-SS1130 report unexpected digital-input states after rewiring?+

S2MMM843-SS1130 can misread the intended state when the dry-contact resistance, SCB100/SCB110 placement or polarity does not match the normally-on or normally-off diagnostic design.

03What should be checked when S2MMM843-SS1130 analog output cannot drive a valve?+

For S2MMM843-SS1130, confirm the channel is assigned as AO, the load is within 230 to 600 ohms, field power is present and open/short detection thresholds have not been set against the actual loop.

04Why does a S2MMM843-SS1130 HART device remain invisible while current is present?+

S2MMM843-SS1130 needs the channel in a supported analog mode, one HART device on that channel and a compatible PRM path; also check loop impedance and whether mixed DO activity is delaying HART events.

05Can S2MMM843-SS1130 digital outputs be paralleled without changing the drawing?+

No. S2MMM843-SS1130 parallel-output use requires the documented adjacent-channel terminal arrangement, load-current calculation and temperature derating to be reflected in the external-terminal-board drawing.

06What details should be sent for a S2MMM843-SS1130 quotation?+

For S2MMM843-SS1130, send the complete suffix, quantity, installed base plate, ProSafe-RS release, redundancy use, destination and a clear nameplate photo so the explosion and G3 selections stay attached to the enquiry.

06

Company Profile

Moore Automation

https://www.mvme.cn

Moore Automation supplies industrial automation components for PLC, DCS, drive, HMI, safety and monitoring systems. Enquiries are organized around the requested manufacturer, complete model, quantity and destination so commercial and shipping details remain in one record.

Component scopeControl, I/O, drive and monitoring parts
Enquiry recordsBrand, model and quantity kept together
Document handlingAvailable product files linked to the request
07

Suggested Products

Siemens6ES7138-7EA00-0AA0
Siemens6AV6643-0DD01-1AX0
B&RX20AI4222
Siemens6DD1660-0BA0
Siemens6GK7443-1EX11-0XE0
Vibro-Meter111-902-000-011
Siemens6GK5208-0BA00-2AC2
Siemens6ES5941-7UA12
ABBSPHSS13
Siemens6ES7531-7LH00-0AB0
Siemens6GK7542-5FX00-0XE0
HIMA982211497
Siemens6ES5 541-8AA11
Siemens6AV6542-0CA10-0AX0
Bently Nevada3500 System
Rockwell Automation160-AA08NSF1
EmersonKJ3206X1-BA2
EmersonKL2001X1-BC1
FoxboroFBI100
EmersonKJ4110X1-BB1
EmersonKJ4110X1-BC1
YokogawaPW484-50
EmersonKC4011X1-BP1
EmersonKC3010X1-BA2
B&RX20AI4632
EmersonCE4003S2B6
EmersonSE4206P2
Vibro-Meter111-902-000-013
Emerson5X00300G02
EmersonKL2001X1-BD1
EmersonKL2002X1-BC1
GEIC600PM541
Siemens7MH4950-1AA01
EmersonSE5009
TriconexTRICON 3009X
Siemens6ES7972-0AA02-0XA0
EmersonSE4022
Rockwell Automation160-AA12NSF1
Siemens6ES7135-7TD00-0AB0
EmersonKL2101X1-BA1
FoxboroFBI200
Siemens6ES7653-2CM00-0XB0
EmersonSE4016
YokogawaAAP135-S50
Siemens6GK1161-3AA00
ABBSPFEC12
Siemens6GK7343-1EX30-0XE0
Bosch RexrothTDM7.1-030-300-W1
HIMA982200512
Siemens6DL1132-6BH00-0EH1
Woodward8440-2080
Bently Nevada3300 XL 8 mm
Siemens6FX2001-5FN13
GEIC600PM542
Bosch RexrothTDM7.1-050-300-W1
Siemens6GK5206-1BC00-2AF2
TriconexTRICON 8310
Woodward9907-163
Siemens6SL3210-5HE11-5UF0
ABBSPIET800
Contact InformationMoore Automation
ManagerLeonia
WhatsApp+86 180 3017 5807

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.