Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa AAI143-S53/K4A00 G3 Isolated Analog Input Module
Yokogawa AAI143-S53/K4A00 G3 Isolated Analog Input Module

Yokogawa AAI143-S53/K4A00 G3 Isolated Analog Input Module Item NO.: 2932059

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa AAI143-S53/K4A00 G3 Isolated Analog Input Module
Item NO. 2932059
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-12

Yokogawa AAI143-S53/K4A00 | G3 Isolated Analog Input Module
Yokogawa · CENTUM VP FIO

Yokogawa AAI143-S53/K4A00 G3 Isolated Analog Input Module

Exact model and suffix configuration
01

Product Introduction

Yokogawa AAI143-S53/K4A00 is a 16-channel isolated 4-20 mA input module for the CENTUM VP FIO system with ISA G3 and -20 to 70 °C environmental capability. It receives transmitter current and converts each channel into process input data for the controller.

Each channel of Yokogawa AAI143-S53/K4A00 selects either a two-wire loop powered from the module or a four-wire transmitter with its own supply. The mode changes how power enters the loop, while the isolated input circuit measures the same 4-20 mA signal range in either arrangement.

Field signals reach Yokogawa AAI143-S53/K4A00 through the AEA4D terminal board, KS cable and ATK4A-00 adapter. Those components preserve the channel order from the field termination to the module, and the isolated conversion separates each current input from the system-side electronics.

02

Specification Details

Brand Yokogawa
Model AAI143-S53/K4A00
Product Name G3 Isolated Analog Input Module
Country Japan (manufacturer)
Input Channels 16, isolated
Input Signal 4 to 20 mA
Environmental Option ISA G3 and -20 to 70 °C
Explosion Protection Not included
Allowable Input Current 24 mA
Accuracy ±16 microampere
Data Update Period 10 ms
Transmitter Power 19.0 V or higher at 20 mA
Current Consumption 230 mA at 5 V DC; 540 mA at 24 V DC
Net Weight Approx. 0.30 kg
Interface Option ATK4A-00 KS cable interface adapter
03

G3 Current Input Deployment

AAI143-S53/K4A00 extends the environmental rating of the input module, while loop design and transmitter-power settings remain channel-specific engineering tasks.

Confirm the G3 order identity

Retain S53 in spares records and inspection photos. A base AAI143 or S50 unit does not document the same environmental selection.

Check the installed location and cabinet conditions against the system design instead of treating G3 as permission to ignore enclosure requirements.

Restore transmitter modes

Record the two-wire or four-wire pin setting for each channel before replacement and verify the correct transmitter power after installation.

A channel with the wrong mode can show zero, saturate or interfere with an externally powered source.

Validate at operating conditions

Use stable current injection and compare several channels after the cabinet reaches normal temperature.

Separate ambient effects from transmitter drift, terminal resistance and controller filtering before changing calibration.

04

KS Cable Commissioning

AAI143-S53/K4A00 relies on ATK4A-00 and the KS cable route, making connector mapping and mechanical condition part of the analog measurement.

Map the AEA4D endpoint

Compare module channel numbers to the terminal-board drawing and test separated points to reveal a connector offset.

Keep the adapter and AEA4D reference in the replacement record so a bare-module order is not mistaken for the complete assembly.

Inspect the cable mechanically

Check latch engagement, pin condition, strain relief and bend radius. Intermittent group faults often follow cable movement rather than electronics failure.

Document any repair or cable replacement before the loop acceptance test.

Prove current at both ends

Measure injected current at the field side and compare the controller value. This locates losses between the source, KS route and module conversion.

When a group is affected, verify shared connections before adjusting individual channels.

05

Product Questions

01Why is S53 important in AAI143-S53/K4A00 replacement work?+

AAI143-S53/K4A00 includes the ISA G3 and -20 to 70 °C option; shortening the order to AAI143 can lead to a different environmental configuration.

02Why does AAI143-S53/K4A00 show zero after a two-wire transmitter replacement?+

For AAI143-S53/K4A00, check the two-wire/four-wire setting, transmitter polarity, available loop power and KS-to-AEA4D channel mapping.

03What can cause a bank of AAI143-S53/K4A00 channels to become unstable?+

AAI143-S53/K4A00 group instability should trigger inspection of KS connector seating, cable movement, grounding and shared field references before module calibration.

04How should AAI143-S53/K4A00 be checked after cabinet temperature changes?+

Test AAI143-S53/K4A00 with stable current sources after thermal stabilization and compare the result with transmitter drift and controller filtering kept separate.

05Can AAI143-S53/K4A00 be supplied with A4S00 termination instead?+

That would be a different option package. AAI143-S53/K4A00 specifically includes ATK4A-00 for the KS cable/AEA4D route, so termination changes require an engineering review.

06What should accompany an AAI143-S53/K4A00 order?+

Send AAI143-S53/K4A00, quantity, AEA4D and KS cable references, channel-powering notes, nameplate photo, destination and inspection requirements.

06

Our Advantages

Moore Automation

https://www.mvme.cn

Moore Automation combines multi-brand component coverage with organized enquiry and shipping records. The service process can connect product identification, available documents, reference photographs, packing information and carrier details without adding unsupported performance promises.

Broad component scopePLC, DCS, drive and monitoring parts
Organized informationProduct and document records connected
Shipment visibilityPacking, carrier and tracking data retained
07

Recommended Models

Siemens6DL1161-6BL00-0PH1
Siemens6GK7542-6UX00-0XE0
GEIS210DRTDH1A
Siemens6SL3054-0EE00-1BA0
Siemens6ES7194-4BC00-0AA0
GEDS200TBSAG1A
Siemens6ES7650-8PC00-1AA0
Siemens6ES7647-0AA00-1YA2
GEIS200TRPGH1B
Siemens6ES7401-2TA01-0AA0
Siemens6ES7132-4BF00-0AB0
B&R8V1180.00-2
Siemens6ES7132-4BF50-0AA0
Siemens6XV1875-5CH10
TriconexTRICONEX 3623
TriconexTRICONEX 3603E
Emerson1C31227G01
Emerson1C31192G01
TriconexTRICONEX 3604E
Emerson1X00691H0
Emerson1C31166G02/1C31169
TriconexTRICONEX 3607E
Emerson1C31167G01
Emerson1X00188H01
TriconexTRICONEX 3611E
Emerson5X00481G04/5X00226G04
Emerson1C31194G01/1C31197G01
Vibro-Meter200-560-101-015
Emerson1C31219G01/1C31223G01
Emerson5X00453G01
Emerson1C31234G01
Woodward5453-754
Siemens7KM9300-0AE01-0AA0
Emerson1C31238H
Woodward8251-046
Siemens6ES7951-0KJ00-0AA0
Emerson1C31224G01/1C31227G01
Woodward8551-0146
Siemens6ES7972-0CB20-0XA0
Emerson5X00167G01
GEIS2020RKPSG2A
Siemens6ES7132-4BD31-0AA0
Emerson1X00781H01L
B&R8V1320.00-2
Siemens7KM9300-0AM00-0AA0
Vibro-Meter200-510-074-113
Siemens6SE7090-0XX84-3DB0
B&R8V1016.00-2
Vibro-Meter200-510-076-114
Siemens6ES7194-4AJ00-0AA0
B&R8V1045.00-2
Vibro-Meter200-560-000-016
Siemens6DD1610-0AK0
B&R8V1090.00-2
Vibro-Meter200-560-000-018
Siemens6ES7193-1CL00-0XA0
TriconexTRICONEX 3614E
GEIS220PTCCH1A
Siemens6ES7122-1BB10-0AA0
Vibro-Meter200-560-101-017
Sales EnquiriesMoore Automation
ManagerLeonia
WhatsApp+86 180 3017 5807

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.