Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa ARS15M-310 32-Channel Solid-State Voltage Input Board
Yokogawa ARS15M-310 32-Channel Solid-State Voltage Input Board

Yokogawa ARS15M-310 32-Channel Solid-State Voltage Input Board Item NO.: 2929212

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa ARS15M-310 32-Channel Solid-State Voltage Input Board
Item NO. 2929212
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-02

Yokogawa ARS15M-310 32-Channel Solid-State Voltage Input Board
YOKOGAWACENTUM SOLID-STATE VOLTAGE INPUT

32-Channel Solid-State Voltage Input Board

Yokogawa ARS15M-310 32-Channel Solid-State Voltage Input Board

01

Model Profile

Yokogawa ARS15M-310 is a 32-channel solid-state voltage input board for CENTUM digital I/O. The -3 execution accepts DC voltage inputs and the -1 mounting code identifies the DIN-rail form with pressure-clamp field termination.

A field voltage entering Yokogawa ARS15M-310 passes through the rectification and insulation circuit, then becomes a digital state for ADV151 with ATD5A or ADV161. The two 16-channel groups share organized internal power while their input states remain individually assigned.

Yokogawa ARS15M-310 installation requires the actual input voltage, polarity, group common and AKB331/AKB337 cable route to match the project drawing. The solid-state circuit removes relay wear but does not remove the need to verify field leakage and OFF-state voltage.

Official full-resolution technical figure for ARS15M-310
02

Technical Parameters

Technical item ARS15M-310
Brand Yokogawa
Model ARS15M-310
Product Name 32-channel solid-state voltage input board
Country Japan
Input Channels 32
Input Execution DC voltage input
Documented ON Level 10 to 30 V DC
Documented OFF Level 1 V DC or less
Supported I/O Module ADV151 with ATD5A or ADV161
Connection Cable AKB331 or AKB337
Field Terminal Pressure clamp
Mounting DIN rail
Channel Groups Two groups of 16
Internal 24 V Consumption 1.0 A maximum
Insulation Resistance 10 MΩ or greater
Withstand Voltage 2 kV AC
Operating Temperature 0 to 50 °C
Operating Humidity 10 to 90% RH, non-condensing
Dimensions 436 × 125.4 mm
Weight Approx. 3.0 kg
03

Operating Characteristics

Yokogawa ARS15M-310 uses a solid-state input path, so switching thresholds and field leakage matter more than mechanical contact motion. The operating assessment must therefore use measured terminal voltage in both states and account for leakage from the connected device rather than treating the input as an ideal switch.
01

State discrimination

The input circuit separates the documented 10–30 V DC ON range from the 1 V DC-or-less OFF condition. Verify a known OFF source first; residual voltage above the OFF limit can keep the solid-state channel logically active even with the device open.

›
02

Insulated conversion

Rectification and insulation turn the field voltage into a controller-compatible state while keeping the field circuit separated from the module side. Apply the intended ON voltage at the field terminal and confirm the same point in the controller, avoiding a test that bypasses the installed common path.

›
03

Group behavior

A shared supply or common issue can affect one 16-channel group, while isolated point failures remain tied to individual field circuits. When several points move together, compare the group common and supply waveform before concluding that multiple input circuits failed simultaneously.

04

Installation Highlights

Installation Highlights

Yokogawa ARS15M-310

Install Yokogawa ARS15M-310 by preserving polarity, group commons and the DIN-rail pressure-clamp arrangement shown in the cabinet record. Installation is accepted only after the rail mounting, pressure-clamp terminations, cable route and controller point map have been checked as one signal chain.

01

Confirm the input source

Measure the field signal in both states and verify it reaches the documented DC thresholds before landing the conductor. Seat the board on the documented DIN-rail position with power isolated, leaving the required clearance for wiring inspection and heat dissipation.

02

Build the groups consistently

Keep channel numbers, commons and cable assignments in the same order as the controller database and field schedule. Land polarity and group commons in channel order, then perform a pull check so a loose conductor cannot imitate an intermittent solid-state input.

03

Commission at the terminal

Toggle representative points in both groups, compare terminal voltage with the controller state and investigate leakage before changing thresholds. Energize one group at a time and prove known OFF and ON levels before enabling the full channel set in the controller project.

05

Product Help

01Why does Yokogawa ARS15M-310 stay ON after the field device opens?

For Yokogawa ARS15M-310, measure residual voltage and leakage at the terminal; the OFF state must fall to 1 V DC or less.

02How does Yokogawa ARS15M-310 hand converted states to CENTUM I/O?

Yokogawa ARS15M-310 connects to ADV151 with ATD5A or ADV161 through AKB331/AKB337 cabling.

03What does the 310 suffix mean on Yokogawa ARS15M-310?

On Yokogawa ARS15M-310, 3 identifies the DC input execution, 1 identifies DIN-rail mounting and 0 is the basic option code.

04Why do multiple Yokogawa ARS15M-310 points change together?

A repeated Yokogawa ARS15M-310 group pattern should lead to the shared field supply, common and cable before individual channels are blamed.

05Can Yokogawa ARS15M-310 replace a relay input board without checks?

No. Yokogawa ARS15M-310 uses voltage thresholds and solid-state circuits, so field source, leakage and terminal arrangement must be reviewed.

06How is Yokogawa ARS15M-310 commissioned safely?

Commission Yokogawa ARS15M-310 with power isolated during wiring, then energize one group and prove known OFF and ON voltages before releasing all points.

06

Customer Support

Moore Automation

https://www.mvme.cn/

Moore Automation provides a clear contact route for industrial hardware questions and product-record clarification. The enquiry can include photographs, installed-system notes and the complete article string so follow-up stays focused on the requested item.

ClarificationComplete references reduce ambiguity
Supporting evidencePhotos and records can follow
Named contactOne route for the enquiry
Request detailQuantity and destination stay visible
Moore Automation Customer Support original image
07

Similar Products

Rockwell Automation2097-V34PR3-LM
Rockwell Drives80026-044-06-R
Rockwell Automation1756-OF8I
MotorolaMVME147-010
MotorolaMVME2604-1151A
GEIS210DTTCH1A
GEIS210DSVOH1A
Rockwell Drives80190-299-01/9
GE Excitation4176J86-G01
ABBPM5680-2ETH-XC
TriconexTRICON 8107X
ABBPM583-ETH-XC
GEIS210JPDDG1A
GEIC3600TRLM1A
MotorolaMVME2604-1141
GE Excitation4161J28-G03
GE ExcitationDS3800NDAC1B1C
GEIS200TTURH1C
GEIC200BEM104
GEIC200PBI001
ABB RoboticsSIB-02
Rockwell Automation1766-L32BWAA
GEIC3600VANB1
SiemensSD831
GE ExcitationDS3800NPPC1J1J
MotorolaMVME2700-761-IO
TriconexTRICON 8403X-1
GEHE800RTD000
Rockwell Drives81001-450-51-R
GE ExcitationDS3800HMAA
GEHE800THM100
GEIC200PWR101
GEIC630MDL306
YokogawaAFV30D-A41262
GEDS200DMCBG2A
GEIS200TBCIH1C
YokogawaAAI543-H50/K4A00
Rockwell Automation5069-L340ERMS2
Rockwell Automation2198-H025-ERS2
SiemensSM560-S-FD-4
TriconexTRICON 8120X
GEIS220PPDAH1A
GEDS200DTBCG1A
GEIC630MDL366
ABBDI525
GEIC200BEM003
Emerson EPROSNG-CON041-SF
GEDS200EXDEG1A
GEIC3600EPZU1
GEDS200DTBDG1A
MotorolaMVME2304-900
SiemensSM560-S-FD-1
GEIS200SRTDH2A
ABB Robotics3HAC034165
YokogawaA2FV50D-A412000
GEIC630MDL324
YokogawaA2FV70D-A411000/HKU
GEIS230SNAIH2A
GEHE800DQM406
GEIS200EACFG2A
08

Sales Assistance

Moore Automation

Send the complete model and requested quantity.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.