Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa ASD143-P00 S1 / ASD533-S00 S1 | Digital I/O Modules with Built-In Barriers
Yokogawa ASD143-P00 S1 / ASD533-S00 S1 | Digital I/O Modules with Built-In Barriers

Yokogawa ASD143-P00 S1 / ASD533-S00 S1 | Digital I/O Modules with Built-In Barriers Item NO.: 2929204

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa ASD143-P00 S1 / ASD533-S00 S1 | Digital I/O Modules with Built-In Barriers
Item NO. 2929204
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-02

Yokogawa ASD143-P00 S1 / ASD533-S00 S1 | Digital I/O Modules with Built-In Barriers

YOKOGAWA · CENTUM ENGINEERING RECORD

Yokogawa ASD143-P00 S1 / ASD533-S00 S1 | Digital I/O Modules with Built-In Barriers

CENTUMI/OMODULE
01

Model Profile

Yokogawa ASD143-P00 S1 and Yokogawa ASD533-S00 S1 are isolated digital I/O modules with built-in barriers for CENTUM field I/O. Yokogawa ASD143-P00 S1 acquires sixteen NAMUR-compatible inputs and adds pulse-count handling, while Yokogawa ASD533-S00 S1 drives eight isolated status outputs for connected field circuits.

On Yokogawa ASD143-P00 S1, current from a NAMUR sensor crosses the isolated interface and becomes status or pulse data for the FCS. Yokogawa ASD533-S00 S1 performs the reverse control path: an FCS output state drives the barrier output stage, which supplies approximately 12 V at 40 mA and rises toward 26 V at zero load.

Yokogawa ASD143-P00 S1 uses the ATSB4 terminal family, whereas Yokogawa ASD533-S00 S1 uses ATSD3 terminals. The single or dual-redundant execution must match the installed node, and the barrier circuit, field device, cable and equipotential-bonding arrangement must be verified as one intrinsically safe system.

02

Technical Parameters

TECHNICAL ITEM
Brand Yokogawa
Model ASD143-P00 S1 ASD533-S00 S1
Nameplate Suffix S1 S1
Product Name NAMUR digital input module with built-in barrier and pulse count Digital output module with built-in barrier
Country Japan
I/O Direction Input Output
Channels 16 isolated 8 isolated
Signal Standard NAMUR, IEC 60947-5-6 12 V at 40 mA; 26 V at 0 mA
Execution Pulse count (-P) Standard (-S)
Function Status and pushbutton input Status output
Input Response 15 ms Not applicable
Minimum ON Detection 20 ms Not applicable
Maximum ON/OFF Cycle 25 Hz Not applicable
Output Response Not applicable 10 ms
Withstand Voltage 1500 V AC
Barrier Interface Isolated
External Terminal ATSB4 pressure-clamp family ATSD3 pressure-clamp family
Single Execution Option /SB4S0 with ATSB4S-0 /SD3S0 with ATSD3S-0
Dual-Redundant Option /SB4D0 with ATSB4D-0 /SD3D0 with ATSD3D-0
Current Consumption 150 mA at 5 V plus 110 mA at 24 V 150 mA at 5 V plus 500 mA at 24 V
Environmental Execution ISA G3 and -20 to 70 °C option
Dimensions 32.8 × 130 × 107.5 mm
Weight Approx. 0.30 kg
03

Product Functions

The two modules serve opposite directions in the CENTUM digital signal path: ASD143-P00 S1 converts NAMUR field states and pulse transitions into FCS data, while ASD533-S00 S1 converts FCS commands into isolated field outputs.

01

NAMUR state acquisition

ASD143-P00 S1 evaluates the NAMUR current state on each isolated channel and presents the accepted condition to the FCS without combining the field circuits at a shared return.

02

Pulse transition handling

The -P execution of ASD143-P00 S1 accepts pushbutton or pulse transitions up to the specified 25 Hz cycle rate so discrete events can be counted rather than treated only as static status.

03

Isolated output command

ASD533-S00 S1 receives a controller command through the I/O interface and drives the assigned field circuit through its barrier output stage; the connected load determines the terminal voltage within the stated output characteristic.

04

Safety and Compliance

Built-in barriers do not make the module alone an approved hazardous-area loop. The selected field device, cable, terminal execution and bonding method must satisfy the entity and installation requirements together.

01

Match the associated apparatus

Confirm that the NAMUR sensor connected to ASD143-P00 S1 or the load driven by ASD533-S00 S1 has entity parameters compatible with the documented barrier circuit before conductors are landed.

02

Preserve terminal execution

Use ATSB4 terminals with ASD143-P00 S1 and ATSD3 terminals with ASD533-S00 S1, then match the single or dual-redundant option to the installed node instead of interchanging terminal families.

03

Verify bonding and commissioning

With field energy isolated, inspect conductor segregation and equipotential bonding, prove each channel with an approved test method, and record the barrier, terminal and field-device combination before service.

05

Product Help

01Can Yokogawa ASD143-P00 S1 / ASD533-S00 S1 be exchanged in the same position?

No. Yokogawa ASD143-P00 S1 / ASD533-S00 S1 have opposite signal directions, different channel counts and different terminal families, so the installed function and terminal execution must match the exact model.

02Which terminal blocks belong to Yokogawa ASD143-P00 S1 / ASD533-S00 S1?

Yokogawa ASD143-P00 S1 / ASD533-S00 S1 use the ATSB4 and ATSD3 pressure-clamp families respectively; select the documented single or dual-redundant option for the node arrangement.

03What distinguishes Yokogawa ASD143-P00 S1 from Yokogawa ASD533-S00 S1?

Yokogawa ASD143-P00 S1 adds pushbutton and pulse-count handling with a maximum 25 Hz ON/OFF cycle, whereas Yokogawa ASD533-S00 S1 is an output module that drives isolated status circuits rather than counting input transitions.

04How should the output path of Yokogawa ASD143-P00 S1 / ASD533-S00 S1 be tested?

With Yokogawa ASD143-P00 S1 / ASD533-S00 S1, test ASD533-S00 S1 using the approved field load and command the point OFF and ON while checking the loop response; ASD143-P00 S1 is checked from the input side with a compatible NAMUR source.

05Does Yokogawa ASD143-P00 S1 / ASD533-S00 S1 alone establish hazardous-area compliance?

No. Yokogawa ASD143-P00 S1 / ASD533-S00 S1 must be evaluated with the field device, cable, terminal block, entity parameters and equipotential-bonding arrangement as one intrinsically safe system.

06How is a safe removal boundary established for Yokogawa ASD143-P00 S1 / ASD533-S00 S1?

For Yokogawa ASD143-P00 S1 / ASD533-S00 S1, de-energize the node and every source connected to the hazardous-area circuits, prove the isolated state, and preserve channel and terminal identities before disturbing conductors.

06

Brand Supply Scope

Moore Automation

https://www.mvme.cn/

Moore Automation works with control-system, PLC, I/O, communication and monitoring references from multiple industrial brands. Each request retains the exact manufacturer and complete identifier so similar product families stay distinguishable.

Control platformsPLC and DCS families
CommunicationNetwork and interface modules
Product recordExact model string retained
07

Similar Products

MotorolaMVME2604-761
MotorolaMVME167-034B
GEIC630MDL311
MotorolaMVME61006E-0163R
ABB Robotics3HAC031580-001
MotorolaMVME2304-0133
FoxboroFBM207B
MotorolaMVME172PA-652SE
GEHE800MIX902
Rockwell Automation1756-L81EP
GEIS200EGPAG1B
ABBTB521-ETH
MotorolaMVME55006E-0163R
GEDS200TCCAG1B
GEIC200CPU001
MotorolaMVME5110-2263
GEIS200STAIH2A
GEDS200SNPAH1A
GE ExcitationDS3800NDAD1H1C
Bently NevadaRanger Pro 70M403
Rockwell Automation20F1ANC170JA0NNNNN
ABB Robotics3HAC033224-001
ABBPM5675-2ETH-XC
GEDS200EXPSG1ABB
GEIS220PDIOH1A
Rockwell Automation1783-ETAP3T
GEIC200UDD220
GEDS200CPCAG1A
GEDS200TBQGG1A
GEIS200EDEXG1B
Rockwell Drives80190-478-51
GEIS215UCVEH2B
GEIS200TPROH1C
ABB Robotics3HAC10939-6
ABBTU834
Rockwell Automation5069-L320ERMS2
GEIC3600SNCF1
Bently Nevada990-10-XX-01-00 / 165353-01
GEIS200EAUXH1A
GEHE800JCM205
Rockwell Automation2097-V33PR5-LM
MotorolaMVME147-001
EmersonKJ3241X1-BA1 + KJ3003X1-EA1
GEHE800ADC120
B&RX20CP0484-1
GEIS230SNAOH2A
GE ExcitationDS3800HSDD
GEIC200ALG266
Rockwell Automation1734-OB8S
GEIC630MDL376
ABB Robotics3HAC044504-001
Rockwell Automation1734-IB8S
Rockwell Automation1756-OB32E
GEHE800DIQ712
FoxboroFBM207C
GEIS215ACLEH1C
GEDS200QTBAG1A
ABB Robotics3HAC021455-001
ABB Robotics3HAC050308-003
GEIS200EDCFG1A
08

Sales Assistance

Discuss the exact product record

MANAGERLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.