Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>YOKOGAWA>Yokogawa ARM55D-000 S1 / ARM55C-000 S1 32-Channel Mechanical Relay Contact Output Boards
Yokogawa ARM55D-000 S1 / ARM55C-000 S1 32-Channel Mechanical Relay Contact Output Boards

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 32-Channel Mechanical Relay Contact Output Boards Item NO.: 2929213

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Yokogawa ARM55D-000 S1 / ARM55C-000 S1 32-Channel Mechanical Relay Contact Output Boards
Item NO. 2929213
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category YOKOGAWA
Brand YOKOGAWA
Creation Time 2026-11-02

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 32-Channel Mechanical Relay Contact Output Boards
YOKOGAWACENTUM MECHANICAL RELAY OUTPUT

32-Channel Mechanical Relay Contact Output Boards

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 32-Channel Mechanical Relay Contact Output Boards

01

Product Profile

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 are 32-channel mechanical-relay output boards for CENTUM field I/O. ARM55D-000 S1 provides M4 normally-open dry-contact outputs, while ARM55C-000 S1 provides M3.5 changeover contacts with both normally-open and normally-closed terminals.

Controller commands reach Yokogawa ARM55D-000 S1 / ARM55C-000 S1 through ADV551 with ATD5A or ADV561 and the AKB331/AKB337 cable route. The board relays then switch the externally supplied load circuits; the backplane command does not provide the load energy.

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 differ in terminal form, contact arrangement and permitted field load. Replacement and commissioning therefore follow the exact board identifier and connected load, not only the shared 32-output count.

Official full-resolution technical figure for ARM55D-000 S1 / ARM55C-000 S1
02

Performance Specifications

Technical item
Brand Yokogawa
Model ARM55D-000 S1 ARM55C-000 S1
Product Name 32-channel NO mechanical relay output board 32-channel NO/NC mechanical relay output board
Country Japan
Output Channels 32
Terminal M4 screw M3.5 screw
Contact Form Normally open Normally open / normally closed
Supported I/O Module ADV551 with ATD5A or ADV561
Connection Cable AKB331 or AKB337
Minimum Load 5 V DC, 10 mA
Maximum Load 250 V AC 2 A; 30 V DC 2 A; 125 V DC 0.1 A 30 V DC 1.5 A
Internal 24 V Consumption 0.65 A maximum 0.85 A maximum
Operating Temperature 0 to 50 °C
Operating Humidity 10 to 90% RH, non-condensing
Dimensions 482.6 × 132.5 mm, 3U
Weight Approx. 2.2 kg
03

System Integration

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 translate controller output states into two distinct relay-contact interfaces for external load circuits. System integration requires the controller command, the selected contact form and the external load source to remain separate but traceable parts of one output circuit.
01

Controller command path

ADV551 or ADV561 passes each output command through the ATD5A and AKB cable arrangement to its assigned board relay. The ADV output path commands the board relay; it does not supply the load energy, so the external source and return must be shown on the field drawing.

›
02

Field-load boundary

The external circuit supplies the load current; the relay contact only makes or breaks the documented path. Choose the NO-only or changeover terminal plan before wiring because the ARM55C execution adds an NC path that changes fail-state behavior.

›
03

Contact selection

ARM55D-000 S1 supports NO circuits, whereas ARM55C-000 S1 also exposes NC contacts and therefore changes the terminal schedule. Commission each output with the actual load source and verify that controller indication, relay operation and field-device response occur on the same point.

04

Diagnostics and Protection

Diagnostics and Protection

Yokogawa ARM55D-000 S1 / ARM55C-000 S1

Troubleshooting Yokogawa ARM55D-000 S1 / ARM55C-000 S1 separates the controller command, relay action and external load circuit before hardware is replaced. The diagnostic sequence protects both the board and the connected equipment by testing command, contact and load independently before a relay is declared defective.

01

Verify the command

Confirm the corresponding controller output and board relay indication before opening the field circuit. First compare the controller command with the board indication; a missing command should be resolved upstream rather than at the field terminals.

02

Measure across the contact

Check the actual NO or NC terminal pair under the applied load, including the external source and return. Next measure the selected NO or NC contact under load and include the external fuse, source and return in the check.

03

Protect inductive loads

Use suitable suppression for coils and other inductive loads so contact arcing does not shorten relay life or disturb neighboring circuits. For coils and other inductive loads, inspect suppression and switching duty because contact arcing can shorten relay life without producing an immediate hard fault.

05

Technical Questions

01Can Yokogawa ARM55D-000 S1 / ARM55C-000 S1 be interchanged directly?

No. Yokogawa ARM55D-000 S1 / ARM55C-000 S1 differ in terminal size, contact form and maximum load, so the exact field circuit must be reviewed.

02Why is a Yokogawa ARM55D-000 S1 / ARM55C-000 S1 load off although the controller output is ON?

For Yokogawa ARM55D-000 S1 / ARM55C-000 S1, check the board relay, external source, selected NO/NC terminal, return and load continuity.

03Which modules drive Yokogawa ARM55D-000 S1 / ARM55C-000 S1?

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 use ADV551 with ATD5A or ADV561 through the documented AKB331/337 cable.

04What load is too small for Yokogawa ARM55D-000 S1 / ARM55C-000 S1?

Yokogawa ARM55D-000 S1 / ARM55C-000 S1 specify a minimum switching load of 5 V DC at 10 mA; lower wetting current may not be reliable.

05How should inductive loads be connected to Yokogawa ARM55D-000 S1 / ARM55C-000 S1?

Add the appropriate suppression at the load for Yokogawa ARM55D-000 S1 / ARM55C-000 S1 and verify that the switched voltage/current stay within the selected board rating.

06How can the load circuit be preserved when changing Yokogawa ARM55D-000 S1 / ARM55C-000 S1?

Record the exact Yokogawa ARM55D-000 S1 / ARM55C-000 S1 model, NO/NC terminal pair, load supply, fuse and controller point before moving wires.

06

Our Advantages

Moore Automation

https://www.mvme.cn/

Moore Automation combines multi-brand automation coverage with model-led enquiry records. Product references, requested quantity and destination details are organized together instead of being separated across unrelated messages.

Multi-brand scopePLC, DCS and instrumentation
Record continuityRequest details stay together
Concise reviewCommercial facts prioritized
Direct communicationOne contact follows the request
Moore Automation Our Advantages original image
07

Compatible Products

GEIS210MVRAH1A
Rockwell Automation2097-V33PR1-LM
GEIC630CHS308
B&RX20CP1684X
ABB Robotics3HAC055699-003
Rockwell Automation5069-L306ERS2
Rockwell Automation2198-H008-ERS2
MotorolaMVME172-263
ABB Robotics3HAC031958-009
FoxboroFBM201C
Rockwell Automation22A-A3P6N104
GEIS200BICLH1A
GEIC200ALG320
GEIS200EROCH1A
GE ExcitationDS3800NVIA1F1C
GE ExcitationDS3800NTBH
GEDS200DTBAG1A
GEIC200CPU002
Rockwell Automation1756-L82ES
YokogawaAAB842
GEIC200ALG325
GEHE800ADC020
MotorolaMVME2700-1331
GEIC630MDL354
Rockwell Automation2198-H015-ERS2
HoneywellCC-GAIX11
GEDS200TCPSG1A
GEIS210DTRTH1A
GEIS200EBRGH2A
GEIS200ACLEH1A
GEIS200EPSMG2A
Rockwell Automation20F11GD027JA0NNNNN
GEDS200DMCBG2AKG
GEIC630MDL316
GE ExcitationDS3800NFEE1G1H
ABB Robotics3HNM13622-1
MotorolaMVME147-023
MotorolaMVME55006E-0163
GEIS200TDBSH2A
Rockwell Automation1756-L85ES
MotorolaMVME147-022
GEIS230SNCIH2A
GEIC200EBI001
GEDS200PTCTG1A
MotorolaMVME51105E-2263
GE Excitation4136J58-G01
GEIS200EMCSG1A
GEIS200JPDDG1A
GEIC630MDL356
Allen-Bradley PanelView20-HIM-A3
Rockwell Drives80190-640-02-R
ABBAO815
GEIS220PAICH1A
MotorolaMVME5100-0163
GEIC200ALG328
GEDS200TBQAG1A
GEIC200UDR006
GEDS200TBQEG1A
Rockwell Automation1794-TB3S
Rockwell Automation2097-V34PR6-LM
08

Request a Quote

Moore Automation

Send the complete model and requested quantity.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.