Current loop acquisition
Each of the 16 channels receives its own 4 to 20 mA loop. Isolation keeps a field-side disturbance from becoming a shared reference across neighboring channels.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa AAI143-H53/K4A0016-Channel Isolated HART Analog Input Module |
| Item NO. | 2932295 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-13 |
Yokogawa AAI143-H53/K4A00 is a 16-channel isolated current-input module for 4 to 20 mA field signals in CENTUM VP field I/O. The H function adds HART communication so the same input path can carry the process current and make supported HART variables available to the control system.
In AAI143-H53/K4A00, the 5 suffix specifies the non-explosion-protected version and the 3 suffix combines G3 environmental construction with the extended -20 to 70 °C operating range. Channel-to-system and channel-to-channel isolation separates the field loops while the module updates process data on a 10 ms cycle.
The /K4A00 option on AAI143-H53/K4A00 identifies the ATK4A-00 KS cable interface adapter. The adapter presents the 16 field loops through the KS cable arrangement, so its channel positions form the physical boundary between cabinet wiring and the isolated input circuits.
| Specification | AAI143-H53/K4A00 |
|---|---|
| Brand | Yokogawa |
| Product Name | 16-Channel Isolated HART Analog Input Module |
| Country | Not specified |
| Platform | CENTUM VP Field I/O |
| Input channels | 16 isolated channels |
| Input signal | 4 to 20 mA DC |
| Allowable input current | 24 mA |
| Input update period | 10 ms |
| Isolation | Channel-to-system and channel-to-channel |
| Withstanding voltage | 1500 V AC for 1 minute |
| HART function | Available |
| Environmental suffix | G3; -20 to 70 °C |
| Explosion protection | Not included |
| Connection option | ATK4A-00 KS cable interface adapter |
| Approximate weight | 0.3 kg |
AAI143-H53/K4A00 joins isolated current measurement with HART device access, so process values and device variables follow defined paths rather than sharing an undifferentiated data stream.
Each of the 16 channels receives its own 4 to 20 mA loop. Isolation keeps a field-side disturbance from becoming a shared reference across neighboring channels.
Supported HART variables are stored with the analog data in the I/O image and can be referenced by the field control station through the normal control-block interface.
The /K4A00 adapter terminates the KS cable arrangement outside the module electronics. Cabinet wiring records should identify the adapter, cable and channel mapping together.
Integration of AAI143-H53/K4A00 depends on the node, terminal interface and engineering database carrying the same channel identity from the field cable to the control function.
Install the module only in a supported FIO node location and retain the slot assignment in the project database, especially where redundant module pairs are engineered.
Configure each loop as a 4 to 20 mA input and associate the correct device tag, HART identity and scaling record before commissioning the control function.
The H53 construction supports the stated G3 and extended-temperature conditions, but the surrounding node, terminal board and cabinet must also satisfy the site environment.
With AAI143-H53/K4A00, isolate whether the current exceeds the configured process range or approaches the 24 mA allowable input limit. Check transmitter output, loop power, polarity and field wiring before changing engineering scaling.
AAI143-H53/K4A00 can still measure the 4 to 20 mA signal when the device, firmware, node HART support or engineering definition does not expose HART variables. Check the loop current first, then verify the HART-capable device, node revision and channel database.
AAI143-H53/K4A00 should not be substituted only by channel count. Confirm isolation, terminal interface, node support, HART requirement, suffix temperature range and the /K4A00 KS adapter before changing the module record.
When several AAI143-H53/K4A00 loops lose HART access together, check the node HART function, engineering download, ATK4A-00 connection and shared KS cable path before treating multiple field devices as failed.
For AAI143-H53/K4A00, compare the KS cable core, ATK4A-00 adapter position and configured channel number with the wiring schedule. A correct process signal on the wrong core can look like a calibration error while the module is operating normally.
AAI143-H53/K4A00 uses H53 for HART capability, non-explosion construction, G3 treatment and the extended operating range, so the node and cabinet environment must match those conditions.
Moore Automation is an industrial automation component supplier working across control systems, PLCs, drives, field I/O and machinery monitoring. Its product scope includes established Yokogawa, ABB, Siemens, Rockwell Automation, GE, Honeywell and Bently Nevada families.
Commercial records are organized by manufacturer, complete model, quantity and destination, with supporting document references kept alongside the quotation and shipment information.
Moore Automation Sales Team