Voltage input group
The input side receives eight 1 to 5 V signals and transfers the converted values to the field control station on the documented update cycle.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Yokogawa AAB841-S50/M4A008 Input / 8-Output Analog I/O Module |
| Item NO. | 2932301 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | YOKOGAWA |
| Brand | YOKOGAWA |
| Creation Time | 2026-11-13 |
Yokogawa AAB841-S50/M4A00 combines eight 1 to 5 V analog inputs and eight 4 to 20 mA analog outputs in one non-isolated field I/O module. The paired input and output groups support applications that need measurement and current actuation within the same module footprint.
In AAB841-S50/M4A00, S identifies the standard type, 5 identifies the non-explosion-protected construction and 0 identifies the basic environmental specification. The analog data update period is 10 ms, while the input and output groups share the module reference rather than providing channel-by-channel isolation.
The /M4A00 option on AAB841-S50/M4A00 specifies the ATM4A-00 MAC2-compatible interface adapter. The adapter separates the eight voltage-input positions from the eight current-output positions and connects both groups to the FIO module through the cabinet-side MAC2 arrangement.
| Specification | AAB841-S50/M4A00 |
|---|---|
| Brand | Yokogawa |
| Product Name | 8-Input / 8-Output Analog I/O Module |
| Country | Not specified |
| Platform | CENTUM VP Field I/O |
| Input channels | 8 |
| Input signal | 1 to 5 V DC |
| Output channels | 8 |
| Output signal | 4 to 20 mA DC |
| Isolation | Non-isolated analog I/O |
| Data update period | 10 ms |
| Environmental class | Basic |
| Explosion protection | Not included |
| Interface option | ATM4A-00 MAC2-compatible adapter |
| Redundant use | Supported with the required identical arrangement |
| Approximate weight | 0.3 kg |
AAB841-S50/M4A00 places two analog functions behind one module identity, with eight voltage measurements and eight current commands handled as distinct channel groups.
The input side receives eight 1 to 5 V signals and transfers the converted values to the field control station on the documented update cycle.
The output side supplies eight 4 to 20 mA commands to compatible loads. Output loop power and load resistance remain part of the external circuit design.
Because the channels are non-isolated, the field wiring and reference arrangement must follow the official connection design rather than assuming independent floating loops.
Connectivity for AAB841-S50/M4A00 is defined by the MAC2-compatible adapter, the channel grouping and the node position recorded in the control system.
The /M4A00 suffix connects the module to the ATM4A-00 adapter, which carries the MAC2-compatible cabinet wiring into the FIO signal interface.
Keep the eight input cores and eight output cores clearly identified at the adapter so a current output cannot be mistaken for a voltage input during cabinet work.
The module exchanges analog values with the field control station through the FIO node; network communication is handled by the node rather than by a standalone Ethernet port on the module.
For AAB841-S50/M4A00, trace the output channel through the ATM4A-00 adapter, loop supply and load return. The application value can be correct even when the external current loop is open or landed on the wrong adapter point.
For AAB841-S50/M4A00, verify that both modules have the same suffix and interface arrangement, occupy the required adjacent positions and use the supported node configuration.
Because AAB841-S50/M4A00 is non-isolated, first check the shared reference, adapter connection and field common before recalibrating individual transmitters. A common reference fault can move several channels in the same direction.
For AAB841-S50/M4A00, compare the ATM4A-00 terminal numbers with separate input and output channel lists; continuity testing should confirm that no 4 to 20 mA output core is landed on a 1 to 5 V input position.
Create separate channel lists for the eight 1 to 5 V inputs and eight 4 to 20 mA outputs of AAB841-S50/M4A00, then tie both lists to the same module and ATM4A-00 adapter record.
AAB841-S50/M4A00 should not replace an isolated design solely because both have eight inputs and eight outputs. Review signal types, common reference, terminal adapter, redundancy and cabinet wiring.
Moore Automation works with a broad industrial product range spanning Yokogawa CENTUM and ProSafe-RS, ABB control systems, Siemens SIMATIC and SINAMICS, Rockwell Automation, GE, Honeywell and Bently Nevada.
The brand range covers distributed control, PLC hardware, field I/O, drives, safety-system components and machinery monitoring products, with each manufacturer and model kept as a separate quotation line.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found