Data intake
The module receives analog values from the controller data image.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Triconex AO3481S2 | Tri-GP analog output module |
| Item NO. | 2918969 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | TRICONEX |
| Brand | TRICONEX |
| Creation Time | 2026-10-13 |
Triconex safety-system hardware
Tri-GP analog output module · Tri-GP safety system · exact-model selection
For analog loop control in Tri-GP, the Triconex AO3481S2 is an analog output module that sends controller-generated values to field control loops. Its complete S2 identity places it in the analog-output path, distinct from digital output and analog input modules in the Tri-GP system.
At the controller side, Triconex AO3481S2 receives an analog value from the Tri-GP data image and applies the configured point mapping. That value leaves through the analog termination assembly as the loop signal for the connected field control circuit.
The field loop completes the path for Triconex AO3481S2: its output pair and common arrangement must match the selected range, while the TriStation 1131 point number keeps the software value aligned with the physical analog-output terminal.
| Technical Item | AO3481S2 |
|---|---|
| Brand | Triconex |
| Product Type | Tri-GP analog output module |
| System | Tri-GP |
| Model Revision | S2 |
| Signal Direction | Controller to field |
| Channel Class | Analog output |
| Loop Type | Analog control loop |
| Architecture | Tri-GP output path |
| Configuration | TriStation 1131 project |
| I/O Role | Output only |
| Termination | Analog output termination assembly |
| Point Mapping | Configured AO points |
| Selection Check | Exact model, suffix, and loop range |
Triconex AO3481S2 turns the Tri-GP controller’s analog value into the field-loop signal assigned to each configured output point.
The module receives analog values from the controller data image.
The configured loop range determines how the controller value is represented at the field terminal.
The output terminal carries the analog signal to the downstream control loop.
Triconex AO3481S2 is complete only when the module identity, termination assembly, loop wiring, and project mapping agree.
Use the configured Tri-GP analog-output position.
Match the output pair and common arrangement to the field loop.
Keep the AO3481S2 identity and point number in the TriStation record.
For Triconex AO3481S2, The controller data image supplies the analog value, the module applies its configured point mapping, and the analog termination sends the resulting signal into the field loop.
Triconex AO3481S2 delivers a continuously represented analog loop value, while a digital output represents an on/off state. The two paths use different I/O roles and termination records.
For Triconex AO3481S2, The S2 suffix belongs to the complete analog-output module identity and stays with the chassis, termination, and TriStation records.
For Triconex AO3481S2, The field loop uses the assigned output pair and common arrangement to carry the analog value. Those conductors must correspond to the selected output range and terminal mapping.
The project point number identifies the physical analog-output terminal on Triconex AO3481S2. The mapping links the controller value to the downstream loop.
For Triconex AO3481S2, No. Its signal direction is controller to field; analog measurements belong on an input path such as the AI module family.