Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>TRICONEX>Triconex AO3481S2 | Tri-GP analog output module
Triconex AO3481S2 | Tri-GP analog output module

Triconex AO3481S2 | Tri-GP analog output module Item NO.: 2918969

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Triconex AO3481S2 | Tri-GP analog output module
Item NO. 2918969
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category TRICONEX
Brand TRICONEX
Creation Time 2026-10-13

Triconex AO3481S2 | Tri-GP analog output module

Triconex safety-system hardware

Triconex AO3481S2 | Tri-GP analog output module

Tri-GP analog output module · Tri-GP safety system · exact-model selection

01

Model Overview

For analog loop control in Tri-GP, the Triconex AO3481S2 is an analog output module that sends controller-generated values to field control loops. Its complete S2 identity places it in the analog-output path, distinct from digital output and analog input modules in the Tri-GP system.

At the controller side, Triconex AO3481S2 receives an analog value from the Tri-GP data image and applies the configured point mapping. That value leaves through the analog termination assembly as the loop signal for the connected field control circuit.

The field loop completes the path for Triconex AO3481S2: its output pair and common arrangement must match the selected range, while the TriStation 1131 point number keeps the software value aligned with the physical analog-output terminal.

02

Technical Details

Technical Item AO3481S2
Brand Triconex
Product Type Tri-GP analog output module
System Tri-GP
Model Revision S2
Signal Direction Controller to field
Channel Class Analog output
Loop Type Analog control loop
Architecture Tri-GP output path
Configuration TriStation 1131 project
I/O Role Output only
Termination Analog output termination assembly
Point Mapping Configured AO points
Selection Check Exact model, suffix, and loop range
03

Product Functions

Triconex AO3481S2 turns the Tri-GP controller’s analog value into the field-loop signal assigned to each configured output point.

01

Data intake

The module receives analog values from the controller data image.

02

Range handling

The configured loop range determines how the controller value is represented at the field terminal.

03

Field delivery

The output terminal carries the analog signal to the downstream control loop.

04

System Integration

Triconex AO3481S2 is complete only when the module identity, termination assembly, loop wiring, and project mapping agree.

01

Rack position

Use the configured Tri-GP analog-output position.

02

Loop wiring

Match the output pair and common arrangement to the field loop.

03

Project mapping

Keep the AO3481S2 identity and point number in the TriStation record.

05

Customer Questions

Where does the value from Triconex AO3481S2 begin and end?

For Triconex AO3481S2, The controller data image supplies the analog value, the module applies its configured point mapping, and the analog termination sends the resulting signal into the field loop.

How is Triconex AO3481S2 different from a digital output?

Triconex AO3481S2 delivers a continuously represented analog loop value, while a digital output represents an on/off state. The two paths use different I/O roles and termination records.

What does the S2 suffix identify on Triconex AO3481S2?

For Triconex AO3481S2, The S2 suffix belongs to the complete analog-output module identity and stays with the chassis, termination, and TriStation records.

Why do the output pair and common matter for Triconex AO3481S2?

For Triconex AO3481S2, The field loop uses the assigned output pair and common arrangement to carry the analog value. Those conductors must correspond to the selected output range and terminal mapping.

How is an AO point mapped in TriStation 1131 for Triconex AO3481S2?

The project point number identifies the physical analog-output terminal on Triconex AO3481S2. The mapping links the controller value to the downstream loop.

Can Triconex AO3481S2 accept a field measurement?

For Triconex AO3481S2, No. Its signal direction is controller to field; analog measurements belong on an input path such as the AI module family.

06

Service Support

Moore Automation

https://www.mvme.cn/

Moore Automation keeps the product details, quantity, destination, and contact route organized before the request moves to dispatch communication.

Information checkThe requested model remains visible beside the enquiry details.
Contact routeThe page identifies Leonia, email, and WhatsApp.
Dispatch coordinationPacking and delivery notes remain associated with the same request.
www.mvme.cn

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.