TRICON CX · 16-Point Commoned External Termination Panel
24 VDC OUTPUT TERMINATION PANEL
Sixteen commoned field-output points for the 3626X module path
The Triconex 9662X-610RF is a 24 VDC, commoned 16-point external termination panel in the Tricon CX field-termination range. It forms the field-wiring end of a 3626X digital-output connection, where the module cable reaches the panel and the panel distributes the output conductors to sixteen labeled points.
One 3626X provides 32 output points, so the 9662X-610RF connection uses two panels to cover the complete module. The two panels divide the outputs into sixteen-point groups while preserving the shared PWR+ and PWR- field-power arrangement defined for the commoned panel.
Field current through the 9662X-610RF is limited by the panel's total continuous rating rather than by point count alone. The combined continuous load across its sixteen output points must remain within 16 A, making panel-level current calculation part of the termination design.
| Technical Item | 9662X-610RF |
|---|---|
| Brand | Triconex |
| Product Type | External Termination Panel |
| Platform | Tricon CX |
| Field Voltage | 24 VDC |
| Point Organization | Commoned |
| Number of Points | 16 |
| Compatible Module | 3626X digital output module |
| Panels per 32-Point Module | 2 |
| Maximum Total Continuous Current | 16 A per panel |
| Field Power Terminals | PWR+ and PWR- |
| Terminal Labels | Point labels supplied for the panel |
| Mounting Function | Field termination between module cable and output wiring |
| Load Terminals | 16 |
| Power Terminal Arrangement | Commoned PWR+ and PWR- |
| Short-Duration Absolute Maximum | 20 A |
| Over-16 A Correction Limit | Correct within 72 hours |
| Supplied Point Labels | Two sets: 1–16 and 17–32 |
The 9662X-610RF receives module output conductors at the panel connector and carries them through labeled terminals to the field loads.
A compatible Tricon CX interface cable brings one sixteen-point half of the 3626X output set to the termination panel.
PWR+ and PWR- provide the shared field-power references used by the sixteen output circuits on the panel.
All energized points share the panel's 16 A maximum total continuous-current allowance, so loads are summed at panel level.
The sixteen positions on one 9662X-610RF are one half of the 3626X module's thirty-two output channels.
One panel terminates a labeled sixteen-point group from the output module cable set.
A second 9662X-610RF terminates the remaining sixteen outputs, completing the 32-point module connection.
Dividing the module across two panels keeps each field conductor on a numbered terminal while retaining the commoned power structure.
Two panels are used for the 32-point 3626X output module. Each 9662X-610RF terminates sixteen points. The supplied 1–16 and 17–32 label sets identify which half of the output module each panel terminates.
The maximum total continuous current is 16 A per panel. The currents of all active points on that panel must be added together. Although the panel can withstand 20 A briefly, any condition above 16 A must be corrected within 72 hours.
Yes. It uses a commoned 24 VDC arrangement with shared PWR+ and PWR- field-power terminals. The common power terminals and the individual load terminals must both be included in the field-wiring plan.
No. Its confirmed module association is the 3626X digital output path, so module, cable and panel model must be checked together. Using another digital-output module requires its own confirmed cable and termination-panel compatibility.
The 3626X output set is divided between two panels. This gives each 9662X-610RF one sixteen-point channel bank. This two-panel relationship should be reflected in both the requested quantity and the terminal-label assignment.
No. The 9662X-610RF is a 16-point external termination panel, while 9666X is a different 32-point field connector; the complete model determines the wiring hardware. Their different point counts and physical formats prevent them from being treated as interchangeable termination parts.
MOORE AUTOMATION
https://www.mvme.cn/Moore Automation keeps the requested manufacturer and complete catalog number visible from enquiry through shipment. Exact suffix review matters for termination hardware because point count, commoning and connector arrangement can change within one product family.
Share the complete model and required quantity for enquiry handling.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found