Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ES7541-1AB00-0AB0 SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module
Siemens 6ES7541-1AB00-0AB0 SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module

Siemens 6ES7541-1AB00-0AB0 SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module Item NO.: 2927520

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ES7541-1AB00-0AB0 SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module
Item NO. 2927520
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-27

Siemens 6ES7541-1AB00-0AB0 | SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module
POINT-TO-POINT6ES7541RS422 / RS485
Siemens · Verified product record

Siemens 6ES7541-1AB00-0AB0 SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module

Interface15-pin D-sub
ProtocolsFreeport / 3964(R) / USS / Modbus
RateUp to 115.2 kbit/s
01

Model Overview

Siemens 6ES7541-1AB00-0AB0 is a SIMATIC S7-1500 point-to-point communication module that adds one isolated RS422 or RS485 serial channel to the station. It receives and transmits telegrams for the CPU program while leaving PROFINET I/O communication on the controller's separate network interfaces.

Through X27 on Siemens 6ES7541-1AB00-0AB0, the 15-pin D-sub assigns separate transmit and receive pairs for four-wire RS422 or a shared pair for two-wire RS485. Incoming characters enter the receive buffer before the CPU program reads the telegram; outgoing program data is framed and placed on the selected serial pair.

Configuration of Siemens 6ES7541-1AB00-0AB0 links physical topology with Freeport, 3964(R), USS or Modbus RTU operation. The connected device must use the same baud rate, frame format and protocol role, while shield bonding, functional ground and termination complete the electrical path before telegram diagnostics can be interpreted.

02

Technical Specifications

Exact-model technical data — read down the left table, then the right
Brand Siemens
Model 6ES7541-1AB00-0AB0
Product Name SIMATIC S7-1500 CM PtP RS422/485 HF Communication Module
Country Germany
Product Family SIMATIC S7-1500
Physical Interface RS422 / RS485
Connector 15-pin D-sub female
Transmission Rate Up to 115.2 kbit/s
Supported Protocols Freeport, 3964(R), USS, Modbus RTU master/slave
Operating LEDs RUN green; ERROR red; RxD/TxD yellow
Isolation Interface and backplane bus isolated
Operating Temperature 0 to 60 °C horizontal; 0 to 40 °C vertical
Protection IP20
Dimensions (W x H x D) 35 x 147 x 127 mm
Net Weight Approx. 0.220 kg
03

Communication and Connectivity

Siemens 6ES7541-1AB00-0AB0 bridges the S7-1500 backplane to one isolated serial network whose physical wiring and telegram format are selected independently.

Choose two or four wires

Use the shared R/T pair on Siemens 6ES7541-1AB00-0AB0 for two-wire RS485, or separate transmit and receive pairs for four-wire RS422 operation.

Select the telegram handler

Configure Freeport for application-defined framing, 3964(R) for its controlled link, or the supported USS/Modbus roles on Siemens 6ES7541-1AB00-0AB0 when the peer protocol requires them.

Observe buffer direction

Send jobs move CPU data toward X27, while receive processing transfers complete or configured telegram sections from Siemens 6ES7541-1AB00-0AB0 back to the user program.

04

Installation Highlights

Install Siemens 6ES7541-1AB00-0AB0 by treating connector assignment, shield continuity and serial topology as one circuit rather than three independent details.

Seat and identify the module

Insert Siemens 6ES7541-1AB00-0AB0 in the assigned S7-1500 slot, attach the front connector and retain the slot address used by the hardware configuration.

Build the shielded cable

Wire the X27 pins for the chosen RS422/485 mode, connect functional GND at pin 8 as required and bond the cable shield at the rail without tying the shield to signal GND.

Commission from the physical layer

Before debugging protocol blocks on Siemens 6ES7541-1AB00-0AB0, confirm polarity, termination, peer baud rate and RxD/TxD LED activity with a short known-good serial path.

05

Common Questions

01

For Siemens 6ES7541-1AB00-0AB0, which pins carry two-wire RS485 data?

For Siemens 6ES7541-1AB00-0AB0, the shared negative path uses pin 4 and the shared positive path uses pin 11; pin 8 is the isolated functional ground.

02

Why do telegram timeouts continue even when the CPU is running when using Siemens 6ES7541-1AB00-0AB0?

Check connector pins, A/B polarity, termination, baud rate, framing and peer role before changing the CPU program. This applies to Siemens 6ES7541-1AB00-0AB0.

03

Can RS422 four-wire wiring use the same pair for transmit and receive on Siemens 6ES7541-1AB00-0AB0?

When checking Siemens 6ES7541-1AB00-0AB0, no. Four-wire mode uses separate transmit and receive pairs; the shared pair is the two-wire RS485 arrangement.

04

When working with Siemens 6ES7541-1AB00-0AB0, what do the yellow LEDs prove?

On Siemens 6ES7541-1AB00-0AB0, rxD and TxD activity shows serial transitions at the module, but it does not prove that framing, address or protocol content is correct.

05

Should the cable shield be connected to signal ground for Siemens 6ES7541-1AB00-0AB0?

No. The shield is bonded according to the S7-1500 installation practice, while signal GND uses the assigned interface pin. Apply this check to Siemens 6ES7541-1AB00-0AB0.

06

With Siemens 6ES7541-1AB00-0AB0, is this exact order number the current successor?

The exact order number is a cancelled version; verify the installed project and interface requirements before considering the named successor 6ES7541-1AB01-0AB0 for Siemens 6ES7541-1AB00-0AB0.

06

Customer Support

Moore Automation

https://www.mvme.cn

Moore Automation keeps model, quantity, destination and available technical records together when responding to industrial automation enquiries.

Photographs and interface notes can be added to the same record, helping customer communication distinguish a serial module from adjacent network or I/O variants.

Model captureFull identifier
Technical notesInterface details retained
Commercial recordQuantity and destination
Response pathOne enquiry history
07

Related Models

Siemens6ES7288-1ST40-0AA0
Rockwell Automation1756-L84ES
GEIC693MAR590C
Schneider Electric140NOE77101
ABBCI854
Bently Nevada330104-00-08-15-02-00
Siemens6ES7288-2DT16-0AA0
Rockwell Automation1756-L8SP
GEIC693MDL204G
Schneider Electric140NOM21100
ABBCI871A
Siemens6ES7288-3AM03-0AA0
Rockwell Automation1756-LSP
GEIC693MDL230C
Schneider Electric140NOM21100C
ABBDI3301
Siemens6ES7288-3AT04-0AA0
Rockwell Automation1756-M03SE
GEIC693MDL330G
Schneider Electric140NOM21200
ABBDI3361
Siemens6ES7288-3AT08-0AA0
Rockwell Automation1756-OB16D
GEIC693MDL645G
Schneider Electric140NOM25200
Siemens6ES7288-3TC04-0AA0
Rockwell Automation1756-OB16I
GEIC693MDL646E
Schneider Electric140NOP85000
Siemens6ES7288-5CM01-2CA0
GEIC693MDL654H
Schneider Electric140SDI95300S
Siemens6ES7288-5DT16-0AA0
GEIC693MDL655H
Schneider Electric140XBP00400
Siemens6ES7288-7ST40-0AA0
GEIC693MDL655J
Schneider Electric140XBP00600
Siemens6ES7288-8SW01-0AA1
GEIC693MDL655K
Schneider Electric140XCP51000
Siemens6ES7305-1BA80-0AA0
GEIC693MDL740H
Schneider Electric140XTS00100
Siemens6ES7307-1BA01-0AA0
GEIC693MDL742D
Siemens6ES7307-1EA00-0AA0
GEIC693MDL751CA
Siemens6ES7307-1EA01-0AA0
Siemens6ES7307-1KA02-0AA0
Siemens6ES7314-1AG13-0AB0
Siemens6ES7314-6CH04-0AB0
Siemens6ES7315-2AB01-0AB0
Siemens6ES7315-2AG10-0AB0
Siemens6ES7315-2EG10-0AB0
Siemens6ES7316-2AG00-0AB0
Siemens6ES7321-1BH02-0AA0
Siemens6ES7321-1BL00-0AA0
Siemens6ES7321-7BH01-0AB0
Siemens6ES7322-1BH01-0AA0
08

Sales Contact

Discuss the exact product requirement
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.