Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ES7505-0RB00-0AB0 SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply
Siemens 6ES7505-0RB00-0AB0 SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply

Siemens 6ES7505-0RB00-0AB0 SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply Item NO.: 2927521

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ES7505-0RB00-0AB0 SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply
Item NO. 2927521
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-27

Siemens 6ES7505-0RB00-0AB0 | SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply
SYSTEM POWER6ES750560 W backplane
Siemens · Verified product record

Siemens 6ES7505-0RB00-0AB0 SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply

Input24 / 48 / 60 V DC
Output60 W backplane
Buffer20 ms
01

Product Description

Siemens 6ES7505-0RB00-0AB0 is a SIMATIC S7-1500 high-feature system power supply that converts a nominal 24, 48 or 60 V DC feeder into as much as 60 W for the station backplane. Its system-bus output supplies the CPU and central modules through the rail connection; it is not a general field-load power source.

Input power for Siemens 6ES7505-0RB00-0AB0 enters through the coded connection plug, passes the reverse-polarity and inrush-limiting stage, and is transferred to the internal backplane supply. Stored energy bridges a short input interruption so the CPU and communication path do not lose backplane power immediately, while external field circuits remain outside that buffered route.

Sizing Siemens 6ES7505-0RB00-0AB0 starts with the summed backplane demand of the installed CPU and central modules. That total is checked against the 60 W output, then the external feeder, conductor size and upstream protection are selected from the actual 24, 48 or 60 V input current before the station is energized.

02

Technical Data

Exact-model technical data — read down the left table, then the right
Brand Siemens
Model 6ES7505-0RB00-0AB0
Product Name SIMATIC S7-1500 PS 60W 24/48/60 V DC HF System Power Supply
Country Germany
Product Family SIMATIC S7-1500
Nominal Input 24 / 48 / 60 V DC
Permitted Input 19.2 to 72 V DC
Input Current 3 A at 24 V; 1.5 A at 48 V; 1.2 A at 60 V
Inrush Current Maximum 8 A for up to 1 s
Backplane Output 60 W
Buffer Time 20 ms
Power Loss Approx. 12 W
Protection Short-circuit and reverse-polarity protection
Dimensions (W x H x D) 105 x 147 x 129 mm
Net Weight Approx. 0.865 kg
03

Product Functions

Siemens 6ES7505-0RB00-0AB0 converts a wide DC feeder range into regulated S7-1500 backplane power and preserves the station through a short supply interruption.

Feed the backplane bus

The regulated output of Siemens 6ES7505-0RB00-0AB0 passes through the rail connection to the CPU and central modules rather than external load terminals. The station power calculation must include every module that consumes energy from this shared bus.

Bridge a brief outage

Internal energy storage in Siemens 6ES7505-0RB00-0AB0 keeps the backplane energized during a short feeder interruption. Field-load circuits are outside this buffered path, so their response must be evaluated separately.

Retain CPU working data

Keeping the system bus alive within the buffer interval allows the CPU and communication modules to continue operating through a brief dip. If the interruption exceeds that interval, the CPU follows its configured power-loss behavior.

04

Installation Highlights

Install Siemens 6ES7505-0RB00-0AB0 as part of the S7-1500 station power path: calculate the backplane load, mount the module on the rail, terminate the selected DC feeder and verify system power before commissioning the CPU.

Calculate the station load

Add the CPU and central-module backplane demand before selecting the installation position for Siemens 6ES7505-0RB00-0AB0. Keep the planned total below the available system-power output, including modules added later.

Mount and wire with power isolated

Secure Siemens 6ES7505-0RB00-0AB0 on the S7-1500 mounting rail and complete the rail connection before terminating the 24, 48 or 60 V DC feeder. Confirm conductor size, polarity and upstream protection against the selected feeder voltage.

Energize and verify the power path

After covers and terminals are secured, energize Siemens 6ES7505-0RB00-0AB0 and check its operating indication together with CPU startup and module recognition. A healthy input indication does not replace verification of the complete backplane load and rail connection.

05

Product Q&A

01

For Siemens 6ES7505-0RB00-0AB0, can this unit power 24 V field sensors?

For Siemens 6ES7505-0RB00-0AB0, its specified 60 W output is for the S7-1500 backplane; field-load power must be provided and calculated separately.

02

How is the correct input current chosen for cable sizing when using Siemens 6ES7505-0RB00-0AB0?

Use the current associated with the actual nominal feeder: 3 A at 24 V, 1.5 A at 48 V or 1.2 A at 60 V, plus protection requirements. This applies to Siemens 6ES7505-0RB00-0AB0.

03

What does the 20 ms buffer cover on Siemens 6ES7505-0RB00-0AB0?

When checking Siemens 6ES7505-0RB00-0AB0, it maintains the system-power output through a short input interruption; it is not a long-duration UPS for the whole panel.

04

When working with Siemens 6ES7505-0RB00-0AB0, why can the station remain underpowered with a healthy input LED?

On Siemens 6ES7505-0RB00-0AB0, compare the summed backplane demand with 60 W and confirm rail connections and module seating.

05

Can the input be connected with reversed polarity for Siemens 6ES7505-0RB00-0AB0?

The module includes reverse-polarity protection, but polarity must be corrected before commissioning rather than relied upon as normal operation. Apply this check to Siemens 6ES7505-0RB00-0AB0.

06

With Siemens 6ES7505-0RB00-0AB0, what should be isolated before removal?

Disconnect and verify the external DC feeder, then release the S7-1500 rail connection according to the installation procedure for Siemens 6ES7505-0RB00-0AB0.

06

Shipping Services

Moore Automation

https://www.mvme.cn

Moore Automation links packing references, selected carrier details and tracking information to confirmed industrial-part shipments.

Products are packed for the recorded quantity and destination; shipment progress is shared when tracking is available from the selected DHL, FedEx, UPS or other carrier service.

PackingItem and quantity checked
CarrierService selected by destination
TrackingReference shared when available
HandoffShipment details retained
07

Recommended Products

Siemens6ES7322-1BL00-0AA0
Rockwell Automation1756-OB32E
GEIC693MDL752C
Schneider Electric140XTS00200
ABBDI524
Bently Nevada330190-045-01-05
Siemens6ES7322-1FF01-0AA0
Rockwell Automation1756-OB8H
GEIC693MDL753D
Schneider ElectricBMXAMI0410
ABBDI561
Siemens6ES7322-8BF00-0AB0
Rockwell Automation1756-OBV8S
GEIC693MDL753H
Schneider ElectricBMXAMI0800
ABBDI562
Siemens6ES7322-8BH10-0AB0
Rockwell Automation1756-OF4
GEIC693MDR390C
Schneider ElectricBMXAMI0810
ABBDI572
Siemens6ES7323-1BH00-0AA0
Rockwell Automation1756-OF8
GEIC693PTM101A
Schneider ElectricBMXAMM0600
Siemens6ES7323-1BL00-0AA0
Rockwell Automation1756-OF8H
GEIC693PWR321AA
Schneider ElectricBMXAMO0210
Siemens6ES7326-1BK02-0AB0
GEIC693PWR321M
Schneider ElectricBMXAMO0802
Siemens6ES7326-2BF01-0AB0
GEIC693PWR321R
Schneider ElectricBMXCPS2000
Siemens6ES7331-7KF02-0AB0
GEIC693PWR321S
Schneider ElectricBMXCPS2010
Siemens6ES7331-7NF00-0AB0
GEIC693PWR321T
Schneider ElectricBMXCPS3020
Siemens6ES7331-7RD00-0AB0
GEIC693PWR321U
Siemens6ES7331-7TB00-0AB0
GEIC693PWR321W
Siemens6ES7331-7TF01-0AB0
GEIC693PWR321Y
Siemens6ES7332-5HB01-0AB0
Siemens6ES7332-5HD01-0AB0
Siemens6ES7332-5HF00-0AB0
Siemens6ES7332-5RD00-0AB0
Siemens6ES7334-0KE00-0AB0
Siemens6ES7336-1HE00-0AB0
Siemens6ES7336-4GE00-0AB0
Siemens6ES7341-1CH01-0AE0
Siemens6ES7350-1AH02-0AE0
Siemens6ES7353-1AH01-0AE0
Siemens6ES7354-1AH01-0AE0
Siemens6ES7374-2XH00-0AA0
Siemens6ES7390-1AE80-0AA0
08

Enquiry Information

Discuss the exact product requirement
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.