Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 6ED1055-1NB10-0BA2 / 6ED1055-1CB10-0BA2 LOGO! DM16 24R / DM16 24 Digital Expansion Modules
Siemens 6ED1055-1NB10-0BA2 / 6ED1055-1CB10-0BA2 LOGO! DM16 24R / DM16 24 Digital Expansion Modules

Siemens 6ED1055-1NB10-0BA2 / 6ED1055-1CB10-0BA2 LOGO! DM16 24R / DM16 24 Digital Expansion Modules Item NO.: 2927508

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 6ED1055-1NB10-0BA2 / 6ED1055-1CB10-0BA2 LOGO! DM16 24R / DM16 24 Digital Expansion Modules
Item NO. 2927508
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-10-27

Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 | LOGO! DM16 24R / DM16 24 Digital Expansion Modules
24 V DIGITAL6ED1055Relay / transistor
Siemens · Verified product record

Siemens 6ED1055-1NB10-0BA2 / 6ED1055-1CB10-0BA2 LOGO! DM16 24R / DM16 24 Digital Expansion Modules

Inputs8 + 8
OutputsRelay / transistor
Width4 MW
01

Product Details

Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 are LOGO! 8 digital expansion modules with eight 24 V DC inputs and eight outputs for extending a compatible LOGO! controller. The DM16 24R ends the control path at relay contacts, whereas the DM16 24 uses sourcing transistor outputs for 24 V DC loads.

On Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, the input terminal groups condition field states before the expansion interface presents them to the LOGO! program. Output decisions travel back through the same interface, but the final hardware path differs: the 24R energizes a relay coil and switches an isolated contact, while the 24 version drives the load from its electronic output supply and return path.

Selection of Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 is therefore governed by the connected load circuit rather than channel count. The relay version can separate its contacts from an AC or DC load supply; the transistor version requires correct DC polarity, a shared return arrangement and a load within the electronic channel limit.

02

Specification Summary

Exact models in the header; shared data is centered, differences use a pale comparison field
Technical Item 6ED1055-1NB10-0BA2 6ED1055-1CB10-0BA2
Brand Siemens
Product Name LOGO! DM16 24R Digital Expansion Module LOGO! DM16 24 Digital Expansion Module
Country Germany
Product Family LOGO! 8
Rated Supply 24 V DC
Permitted Supply 20.4 to 28.8 V DC
Digital Inputs 8
Digital Outputs 8 relay contacts 8 sourcing transistor outputs
Output Current Load-dependent relay rating 0.3 A per channel
Output Protection External circuit protection Electronic short-circuit protection
Input Delay Approx. 1.5 ms
Mounting 35 mm DIN rail
Protection IP20
Operating Temperature -20 to +55 °C
Dimensions (W x H x D) 71.5 x 90 x 58 mm
03

System Integration

Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 occupy the four-unit LOGO! expansion position and exchange input status and output commands with the adjacent base module.

Connect the expansion path

After rail mounting, Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 connect through the LOGO! expansion interface; field conductors remain on the removable terminal groups.

Map channels by installed order

The LOGO! project assigns the added input and output addresses from Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 according to the physical expansion order. Record that order before inserting or moving a module, because a shifted address can make correct field wiring operate the wrong program tag.

Match the load interface

Choose the 24R relay form when galvanic contact separation is needed, or the transistor form when the load is a compatible 24 V DC circuit.

04

Diagnostics and Protection

Fault isolation on Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 separates the shared 24 V input path from the variant-specific relay or transistor output stage.

Check module status

First confirm that Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 are recognized by the LOGO! base module and that the expected I/O addresses are online.

Trace the commanded output path

Start with the online program command for Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, then check the matching terminal and the external load supply. On the relay version test continuity across the commanded contact; on the transistor version follow supply polarity and the protected electronic channel to the load return.

Restore by circuit group

Remove the affected load, clear the wiring fault and retest the corresponding channel on Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2 before reconnecting the full group.

05

Frequently Asked Questions

01

For Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, which variant should be used for AC loads?

For Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, the DM16 24R relay contacts can switch an externally supplied AC circuit within the contact rating; DM16 24 is a DC transistor-output module.

02

Why does the transistor version require polarity checks when using Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2?

Its sourcing outputs depend on correct 24 V DC reference and load return wiring, unlike a potential-free relay contact. This applies to Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2.

03

Can one project use the same channel count for both variants on Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2?

When checking Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, yes, both expose eight inputs and eight outputs, but the electrical output type must still match the field devices.

04

When working with Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, what causes a transistor output to remain off after a short circuit?

On Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, remove the shorted load, confirm current is within 0.3 A per channel and restore the correct module supply before retesting.

05

How should a relay-output fault be separated from a program fault for Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2?

Compare the program command with the physical contact and external load voltage; the relay contact does not create load power. Apply this check to Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2.

06

With Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2, do the two variants need different panel space?

No, both use the four-modular-width housing, but their terminal functions and output wiring are different for Siemens 6ED1055-1NB10-0BA2 / Siemens 6ED1055-1CB10-0BA2.

06

Our Services

Moore Automation

https://www.mvme.cn

Moore Automation supports enquiries for PLC, I/O, communications, power and condition-monitoring components from multiple industrial manufacturers.

Service records keep product photographs, full model strings, quantities and destination notes together so commercial and technical questions refer to one defined item.

Product reviewExact model captured
DocumentationAvailable records organized
Commercial detailQuantity kept with model
CommunicationOne enquiry record
07

Product Recommendations

Siemens6ES7132-4BD00-0AA0
Rockwell Automation1756-EN2TR
GEIC200MDL742
Schneider Electric140CPS11410C
ABBAI562
Bently Nevada200-510-074-114
Siemens6ES7132-4BF00-0AA0
Rockwell Automation1756-EN3TR
GEIC200MDL750
Schneider Electric140CPS11420
ABBAI563
Siemens6ES7132-4HB12-0AB0
Rockwell Automation1756-ENBT
GEIC200MDL750K
Schneider Electric140CPS21400
ABBAI815
Siemens6ES7132-6BF00-0CA0
Rockwell Automation1756-IA16
GEIC200PWR002D
Schneider Electric140CPS22400
ABBAI830A
Siemens6ES7132-6HD00-0BB1
Rockwell Automation1756-IB16IF
GEIC200UAA003-AA
Schneider Electric140CPU11302
Siemens6ES7132-6HD01-0BB1
Rockwell Automation1756-IB32
GEIC200UAA007
Schneider Electric140CPU11303
Siemens6ES7133-1BL01-0XB0
GEIC200UAL004
Schneider Electric140CPU31110
Siemens6ES7134-4GB00-0AB0
GEIC200UAL005
Schneider Electric140CPU42402
Siemens6ES7134-4JB00-0AB0
GEIC200UAL006
Schneider Electric140CPU65150
Siemens6ES7134-4JB50-0AB0
GEIC200UAR028
Schneider Electric140CPU67160
Siemens6ES7134-6HD01-0BA1
GEIC200UDD112
Schneider Electric140CPU67260
Siemens6ES7134-6JD00-0CA1
GEIC200UDD120
Siemens6ES7136-6BA00-0CA0
GEIC200UDD164
Siemens6ES7136-6RA00-0BF0
Siemens6ES7137-6BD00-0BA0
Siemens6ES7138-4CA01-0AA0
Siemens6ES7138-4CB10-0AB0
Siemens6ES7138-4FA04-0AB0
Siemens6ES7138-4FA05-0AB0
Siemens6ES7138-4FB04-0AB0
Siemens6ES7138-4FR00-0AA0
Siemens6ES7142-1BD40-0XB0
Siemens6ES7142-6BF50-0AB0
Siemens6ES7144-4GF01-0AB0
Siemens6ES7151-1AA00-0AB0
08

Contact Details

Discuss the exact product requirement
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.