Product Name Siemens 6DL1131-6BH00-0EH1 DI 16x24VDC HA Digital Input Module
Item NO. 2945552
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-11-26

Siemens 6DL1131-6BH00-0EH1 DI 16x24VDC HA Digital Input Module
16Digital inputs
24 V DC
Signal register
Siemens · SIMATIC ET 200SP HA

Siemens 6DL1131-6BH00-0EH1 DI 16x24VDC HA Digital Input Module

Process-signal acquisition, channel status, event capture and sensor-supply diagnostics in one HA I/O module.

Input formPNP · active high
Terminal choiceH1 standard · M1 redundant
Event resolution1 ms high precision
01

Product Description

Siemens 6DL1131-6BH00-0EH1 is the SIMATIC ET 200SP HA DI 16x24VDC HA digital input module for process-control stations. Its sixteen 24 V DC power inputs receive active-high PNP field signals, convert them into channel states and transfer both process values and quality information through the ET 200SP HA backplane.

Installed on an H1 or M1 terminal block, 6DL1131-6BH00-0EH1 keeps field wiring on the terminal block while the plug-in electronics handle input evaluation, channel LEDs and diagnostic reporting. The M1 terminal block supports a redundant arrangement; the H1 terminal block is used where a single I/O module is required.

Within each channel, 6DL1131-6BH00-0EH1 can apply the configured input delay, pulse stretching and edge evaluation before the state enters the process image. The module can also timestamp transitions, issue configured hardware interrupts and accept channel parameter changes during RUN, while the front output-disable switch separates the module electrically from the process for removal during operation.

02

Technical Specifications

6DL1131-6BH00-0EH1Technical Item register for the exact -0EH1 module version.
Brand
Siemens
Product Type
ET 200SP HA digital input module
Country of Origin
Germany
Input Channels
16 power digital inputs
Input Circuit
PNP, sink input, active high
Rated Supply
24 V DC
Supply Range
19.2 to 28.8 V DC
Terminal Blocks
H1 or M1
Sensor Supply
24 V DC, short-circuit protected
Timestamp Resolution
10 ms or 1 ms high precision
Cycle Time
1 ms; 250 µs with timestamping
Dimensions
115 mm high × 138 mm deep
03

Channel Signal Processing & Event Capture

For 6DL1131-6BH00-0EH1, input conditioning is a sequence rather than a list of independent settings: the electrical transition is stabilized first, an optional pulse extension preserves the visible state, and event functions then evaluate the resulting edge.

01

Stabilize the field transition

The configured input delay suppresses changes that do not persist long enough to be accepted. This prevents a transient at the terminal from becoming a process-image change before the channel electronics have validated it.

02

Hold short accepted pulses

Pulse stretching can retain a short accepted “1” or “0” state for 50 ms to 2 s. A later pulse is either postponed or ignored according to its timing relative to the active extension window, as the complete diagram shows.

03

Record the event edge

Rising, falling or both edges can be evaluated. Standard timestamping uses 10 ms resolution; the high-precision mode uses 1 ms resolution and changes the module cycle to the timestamping cycle.

04

Transfer state and quality

The processed value is transferred with its quality information. This lets the controller distinguish a valid logical state from a state affected by channel or module diagnostics.

04

Sensor Supply, Diagnostics & Redundant Operation

The 6DL1131-6BH00-0EH1 signal path is tied to its terminal-block supply path: L+ and M feed the module, protected sensor-supply circuits serve the field channels, and diagnostics report whether the module or a specific channel can still deliver a dependable value.

Two channel groups

Inputs 1–16 and 17–32 in the terminal assignment are organized around the module electronics and two protected sensor-supply paths. Field commons return to M while L+ enters through the terminal block.

Layered status indication

Green channel LEDs show logical input state; red channel LEDs identify channel faults. DIAG, MT and PWR provide module-level diagnostic, maintenance and supply-voltage context.

Targeted fault reporting

Missing module supply is reported at module level. Sensor-supply monitoring and short circuit to M can be reported at channel level, preserving the location of the affected path.

M1 redundancy pairing

On an M1 terminal block, two modules can form a redundant pair without changing field wiring. The switchover path is designed for a maximum 55 ms failover interval.

05

Frequently Asked Questions

When should 6DL1131-6BH00-0EH1 be installed on an H1 terminal block instead of an M1 terminal block?
Use H1 when 6DL1131-6BH00-0EH1 operates as a single I/O module. Choose M1 when 6DL1131-6BH00-0EH1 must be paired with a second module for I/O redundancy, because M1 provides the shared terminal-block arrangement required by that configuration.
Can a two-wire sensor be connected directly to 6DL1131-6BH00-0EH1?
6DL1131-6BH00-0EH1 accepts 24 V DC PNP, active-high input signals and allows a two-wire sensor quiescent current up to 1.5 mA. The sensor’s off-state leakage and switching levels must remain inside those input limits so the channel does not interpret the idle current as an active state.
How can 6DL1131-6BH00-0EH1 retain a field pulse that is shorter than the controller scan?
Configure pulse stretching on the relevant 6DL1131-6BH00-0EH1 channel after selecting an input delay that still accepts the pulse. The module can hold an accepted 0 or 1 state for 50 ms, 100 ms, 200 ms, 500 ms, 1 s or 2 s, allowing the process image to retain the event long enough for controller evaluation.
Why can timestamping, pulse stretching and hardware interrupts on 6DL1131-6BH00-0EH1 require separate planning?
These 6DL1131-6BH00-0EH1 functions act at different points in the input-processing sequence and are not interchangeable. Timestamping records configured edges, pulse stretching changes the visible duration of an accepted state, and a hardware interrupt asks the controller to react to an edge; the channel settings must therefore reflect the event that actually needs to be preserved.
Which indication helps separate a sensor-supply fault from a module-wide supply problem on 6DL1131-6BH00-0EH1?
6DL1131-6BH00-0EH1 uses PWR and DIAG for the module supply and general diagnostic state, while the red channel fault LEDs identify affected inputs. The controller diagnostics can then distinguish missing module supply from sensor-supply monitoring or a short circuit to M on a channel path.
Does changing one channel of 6DL1131-6BH00-0EH1 during RUN interrupt the remaining channels?
A single 6DL1131-6BH00-0EH1 channel can be reparameterized during RUN through data record 128 without stopping the other channels. If the WRREC transfer is rejected, 6DL1131-6BH00-0EH1 retains the previous parameter values and returns an error status instead of applying a partial channel configuration.
06

Shipping Services

MOORE AUTOMATION
https://www.mvme.cn/

Shipping coordination begins after the manufacturer, complete model, quantity and destination have been recorded. Moore Automation uses those details to prepare the item record, select protective packing appropriate to the shipment and keep dispatch information connected to the same enquiry.

Item CheckManufacturer and full model are matched to the shipment record.
Protective PackingPackaging is arranged around the item format and transport path.
Carrier CoordinationDispatch details follow the agreed destination and contact channel.
Tracking RecordAvailable carrier and tracking updates remain linked to the enquiry.
07

Recommended Products

01Siemens3RV1021-0HA10
02OmronZ4LA-1030
03SICKKTX-WP91142252ZZZZ
04ABB2CCS800900R0041
05Mitsubishi ElectricFX5-CNV-BUSC
06Rockwell Automation194R-LNC3
07WAGO750-403
08FestoCP-E16-M8
09HoneywellGSAC07C
10General ElectricRJO09588
11Siemens3RH1131-2BB40
12OmronCS1G-CPU43H
13SICKDS35-B15521
14ABB1SEP101890R0001
15Mitsubishi ElectricAL2-2TC-ADP
16Rockwell Automation1492-SPM1C320
17WAGO750-504
18FestoMSFG-24
19Honeywell620-0039
20General ElectricDS200TCCAG1AJB
21Siemens3VU1300-1MG00
22OmronC500-NC103
23SICKM40E-034000RR0
24ABBXLP00
25Mitsubishi ElectricQ68ADI
26Rockwell Automation1492-WG6
27WAGO750-614
28FestoADVU-20-5-P-A
29Honeywell4DP7APX0D411
30General ElectricIC697CGR772-GA
31Siemens3RV1915-5A
32OmronCJ1W-PRM21
33SICKM40E-034023RB0
34ABB492838402
35Mitsubishi ElectricF2-6A-E
36Rockwell Automation1492-SPM1D100
37WAGO281-104
38FestoDNG-32-25-PPV-A
39Honeywell620-3030
40General ElectricMVC3001-4003SCA
41Siemens6ES7193-1FL30-0XA0
42OmronCS1W-MAD44
43SICKLMS400-2000
44ABBKC44E
45Mitsubishi ElectricA38HBEU
46Rockwell Automation1492-SPM1D060
47WAGO249-116
48FestoADN-20-10-A-P-A-TL
49Honeywell620-1032
50General Electric469-P5-HI-A20-E-H
51Siemens6SL3060-4AB00-0AA0
52OmronNX102-1000
53SICKCLV490-6010
54ABB2CPX039189R9999
55Mitsubishi ElectricA1S35B-E
56Rockwell Automation1492-CB2F160
57WAGO282
58FestoSIEF-Q40S-PA-S-2L
59Honeywell621-0019
60General ElectricMN42W40
08

Contact Us

Send the complete model and destination.
ManagerLeonia

No related record found

Recently Viewed

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.