Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>SIEMENS>Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter
Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter

Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter Item NO.: 2945621

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter
Item NO. 2945621
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category SIEMENS
Brand SIEMENS
Creation Time 2026-11-27

Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter
07SIMATIC ET 200SP
high-feature electronic reversing motor starter
Official product record
Siemens · SIMATIC ET 200SP

Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter

A 2.8–9 A electronic starter with reversing, overload protection, diagnostics and PROFIenergy functions.

Current range2.8–9 A
Motor powerUp to 4 kW at 400 V
SwitchingElectronic reversing
01

Solution Overview

Forward, reverse and stop commands reach the motor through Siemens 3RK1308-0BD00-0CP0, a SIMATIC ET 200SP high-feature electronic reversing starter. The backplane selects the electronic phase path, and the starter returns operating, warning and trip information to the controller.

The adjustable 2.8–9 A protection range of 3RK1308-0BD00-0CP0 is matched to the connected motor, while overload evaluation remains inside the starter. Electronic switching removes the forward and reverse contactor pair used by an electromechanical starter, but the control program must still define a valid direction-change sequence for the connected load.

Installed on the matching ET 200SP BaseUnit, 3RK1308-0BD00-0CP0 uses the station supply and load infeed defined for the motor-starter group. PROFIenergy can place the starter into a coordinated energy-saving state, and an optional 3DI/LC module adds local digital-input or local-control functions without replacing the backplane command path.

02

Electrical & Mechanical Data

Brand
Siemens
Product Type
ET 200SP high-feature electronic reversing motor starter
Brand Country
Germany
Current Setting Range
2.8–9 A
Motor Rating at 400 V
Up to 4 kW
Switching Technology
Electronic reversing
Overload Protection
Electronic, adjustable
Control Supply
24 V DC
Station Interface
SIMATIC ET 200SP BaseUnit
Energy Function
PROFIenergy
Optional Extension
3DI/LC module
Dimensions
30 × 142 × 150 mm
Degree of Protection
IP20
Installation Width
30 mm
03

Electronic Reversing Operating Characteristics

The 3RK1308-0BD00-0CP0 combines direction switching and current-based protection in one electronic path. Electronic interlocking prevents conflicting internal switching states, but it does not calculate the mechanical stopping time of the driven load. Direction timing remains part of the application design.

01

Command

The station sends forward, reverse or stop through the ET 200SP backplane.

02

Validate

Internal logic checks the requested direction against the current operating state.

03

Switch

Electronic power devices apply the selected motor phase sequence.

04

Protect

The measured motor current is evaluated against the configured overload setting and trip behavior.

04

Starter Monitoring and Control

Three command sources can affect how 3RK1308-0BD00-0CP0 is observed and operated in the station. Local and automatic commands must be assigned according to the configured operating mode. A valid local signal should not be mistaken for an unexplained PLC command.

Automatic

The PLC controls the starter through cyclic ET 200SP process data.

Local Extension

An optional 3DI/LC module adds wired inputs or local-control functions beside the starter.

Diagnostic

Warnings, trip cause and operating state return through the station for HMI or program evaluation.

Energy Pause

PROFIenergy coordinates a defined off state during scheduled production pauses.

05

Model FAQs

Why can 3RK1308-0BD00-0CP0 reject a start command after installation?
Check the motor-current setting, active operating mode, station configuration and any stored trip on 3RK1308-0BD00-0CP0. A valid PLC bit is only one condition in the electronic starter path.
How should the 2.8–9 A range of 3RK1308-0BD00-0CP0 be used?
Set 3RK1308-0BD00-0CP0 to the connected motor nameplate current within the permitted range and verify the application start behavior. Do not use the upper limit as a default protection setting.
How can a local-only operating condition on 3RK1308-0BD00-0CP0 be isolated?
For 3RK1308-0BD00-0CP0, compare the selected control mode, backplane output data and optional 3DI/LC input state. A local command can prove the power path while leaving the automatic command path unresolved.
Does 3RK1308-0BD00-0CP0 need a separate reversing contactor pair?
No. 3RK1308-0BD00-0CP0 performs forward and reverse switching electronically within the starter. The external installation still needs the correct BaseUnit, power infeed and motor conductors.
Why might 3RK1308-0BD00-0CP0 remain off during a planned production pause?
A PROFIenergy command can place 3RK1308-0BD00-0CP0 into its configured energy-saving state even when no fault is present. Check the energy-management status before resetting protection.
Can 3RK1308-0BD00-0CP0 be used on any ET 200SP BaseUnit?
No. 3RK1308-0BD00-0CP0 requires the BaseUnit and infeed arrangement defined for ET 200SP motor starters. Mechanical fit alone does not confirm the power and backplane relationships.
06

Service Support

MOORE AUTOMATION
https://www.mvme.cn/

Moore Automation uses a named sales contact to keep product questions and follow-up connected to the same request. The requested manufacturer, complete model, supplied label images and available data sheets remain visible while the enquiry progresses.

Named ContactOne communication path maintained
Request CheckManufacturer and full model recorded
Data ReturnAvailable sheets coordinated
Follow-upStatus questions remain connected
07

Comparable Models

WAGO750-323
FestoADVUL-40-10-PA
Honeywell621-3560RC
General ElectricDS200TBQBG1ACB
Siemens6ES7138-4CA00-0AA0
OmronNT20S-ST121-V1
SICKWL12G-3P2582S04
ABBKC6-40E
Mitsubishi ElectricAJ71BR11
Rockwell Automation1771-P5
WAGO750-430
FestoADN-40-50-A-PPS-A-90K8-EX4
Honeywell620-0060
General Electric25HP
Siemens6ES5451-4UA13
OmronS82G-1024
SICKT4000-1RBA01
ABB2CDG110167R0011
Mitsubishi ElectricAY41
Rockwell Automation1715-A3IO
WAGO753-440
FestoADN-63-20-I-PPS-A
Honeywell620-0053
General ElectricS7730DVT-EFC2
Siemens5SN3
OmronCS1G-CPU42H
SICKMPS-032TSTP0
ABB1SDA104940R1
Mitsubishi ElectricFR-CBL-03
Rockwell Automation1756-A4
WAGO750-343
FestoCRVZS-0.4
Honeywell620-0080
General ElectricDS200DTBAG1AAA
Siemens3TH8280-0A
OmronCJ1W-PRT21
SICKWT34-R220
ABBRD3P
Mitsubishi ElectricQD75P1
Rockwell Automation802M-AY5
WAGO750-514
FestoDNC-63-25-PPV-A
HoneywellJ-KRA00
General Electric703-1442-02
Siemens8120668
OmronNS5-SQ10B-ECV2
SICKWTF12-3P2431
ABB1SAJ510001R0002
Mitsubishi ElectricA0J2-E24T
Rockwell Automation1492-ACABLE050TB
WAGO750-611
FestoADVU-25-85-P-A
Honeywell82407364-001
General ElectricIC200EBI001-NJ
Siemens3RX9800-0AA00
OmronCJ1W-FLN22
SICKWLG4S-3P2232V
ABB2CDG110080R0011
Mitsubishi ElectricMT-Y16T
Rockwell Automation1771P4R
08

Contact Our Team

Send the complete brand, model and destination.
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.