Command
The station sends forward, reverse or stop through the ET 200SP backplane.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Siemens 3RK1308-0BD00-0CP0 ET 200SP Reversing Starter |
| Item NO. | 2945621 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | SIEMENS |
| Brand | SIEMENS |
| Creation Time | 2026-11-27 |
A 2.8–9 A electronic starter with reversing, overload protection, diagnostics and PROFIenergy functions.
Forward, reverse and stop commands reach the motor through Siemens 3RK1308-0BD00-0CP0, a SIMATIC ET 200SP high-feature electronic reversing starter. The backplane selects the electronic phase path, and the starter returns operating, warning and trip information to the controller.
The adjustable 2.8–9 A protection range of 3RK1308-0BD00-0CP0 is matched to the connected motor, while overload evaluation remains inside the starter. Electronic switching removes the forward and reverse contactor pair used by an electromechanical starter, but the control program must still define a valid direction-change sequence for the connected load.
Installed on the matching ET 200SP BaseUnit, 3RK1308-0BD00-0CP0 uses the station supply and load infeed defined for the motor-starter group. PROFIenergy can place the starter into a coordinated energy-saving state, and an optional 3DI/LC module adds local digital-input or local-control functions without replacing the backplane command path.
The 3RK1308-0BD00-0CP0 combines direction switching and current-based protection in one electronic path. Electronic interlocking prevents conflicting internal switching states, but it does not calculate the mechanical stopping time of the driven load. Direction timing remains part of the application design.
The station sends forward, reverse or stop through the ET 200SP backplane.
Internal logic checks the requested direction against the current operating state.
Electronic power devices apply the selected motor phase sequence.
The measured motor current is evaluated against the configured overload setting and trip behavior.
Three command sources can affect how 3RK1308-0BD00-0CP0 is observed and operated in the station. Local and automatic commands must be assigned according to the configured operating mode. A valid local signal should not be mistaken for an unexplained PLC command.
The PLC controls the starter through cyclic ET 200SP process data.
An optional 3DI/LC module adds wired inputs or local-control functions beside the starter.
Warnings, trip cause and operating state return through the station for HMI or program evaluation.
PROFIenergy coordinates a defined off state during scheduled production pauses.