Command
The ET 200S control record requests forward, reverse or off.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Siemens 3RK1301-0KB00-1AA2 ET 200S Reversing Motor Starter |
| Item NO. | 2945615 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | SIEMENS |
| Brand | SIEMENS |
| Creation Time | 2026-11-27 |
A 0.9–1.25 A standard electromechanical starter that changes motor direction inside an ET 200S station.
Within a SIMATIC ET 200S station, Siemens 3RK1301-0KB00-1AA2 combines two electromechanical contactor paths for forward and reverse running. The selected path applies the required phase sequence, while the interlock prevents both paths from closing together.
Motor power reaches 3RK1301-0KB00-1AA2 through the ET 200S power and terminal-module group. Its overload setting follows the connected motor current within the 0.9–1.25 A range. The 1AA2 suffix identifies this reversing version, while 0AA2 identifies the nearby direct starter.
Status and trip information from 3RK1301-0KB00-1AA2 returns through the ET 200S backplane to the interface module. The plug-in starter can be withdrawn from its matching terminal module without disturbing field wiring, but the power group, terminal-module type and mechanical coding remain part of the usable assembly.
The direction command for 3RK1301-0KB00-1AA2 is converted into one of two mutually exclusive motor-power paths. A direction change should pass through the commanded off state defined by the control program. The internal interlock prevents simultaneous closure but does not define the machine deceleration time.
The ET 200S control record requests forward, reverse or off.
The starter blocks a direction from closing while the opposite contactor path is active.
The selected contactor arrangement applies the required phase sequence to the motor.
Operating and trip state returns to the controller through the station backplane.
The starter body is only one part of the electrical chain used by 3RK1301-0KB00-1AA2. A starter with the correct current range can still be unusable on the wrong terminal module. Check the starter code, terminal module and power-module grouping as one assembly.
The motor-starter power module establishes the load-voltage group for the following positions.
The matching terminal module carries the power rails, control connection and mechanical coding.
The overload setting is matched to the motor nameplate current inside the 0.9–1.25 A range.
Removing the plug-in starter separates the switching device while field conductors remain on the terminal module.
Moore Automation handles enquiries across established automation families including Siemens SIMATIC and SINAMICS, ABB AC500 and AC800M, GE controller platforms, Yokogawa CENTUM and Bently Nevada monitoring components.
Moore Automation Sales Team