Home>Prosoft>ProSoft PLX31-PND-MBS4 PROFINET to Modbus Serial Gateway
ProSoft PLX31-PND-MBS4 PROFINET to Modbus Serial Gateway

ProSoft PLX31-PND-MBS4 PROFINET to Modbus Serial Gateway Item NO.: 2898062

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name ProSoft PLX31-PND-MBS4 PROFINET to Modbus Serial Gateway
Item NO. 2898062
Weight 0.17 kg = 0.3748 lb = 5.9966 oz
Category Prosoft
Brand Prosoft
Creation Time 2026-08-20

ProSoft PLX31-PND-MBS4 PROFINET to Modbus Serial Gateway
ProSoft GatewayPLX31-PND-MBS4

ProSoft PLX31-PND-MBS4 PROFINET to Modbus Serial Gateway

A four-port communication gateway for bi-directional data exchange between a PROFINET controller and Modbus RTU or ASCII serial devices.

Product Profile

Four Serial Channels in One Gateway

  • PROFINET Class A Device
  • Four independent serial ports
  • Modbus RTU and ASCII
  • RS-232, RS-422, and RS-485

PROFINET and Modbus Serial Data Exchange

The ProSoft PLX31-PND-MBS4 connects a PROFINET controller to Modbus serial equipment. Each of its four serial ports can be configured independently as a Modbus master or slave and can use RTU or ASCII communication.

An internal database of 10,000 16-bit registers moves data between the serial channels and the PROFINET cyclic interface. The gateway provides 1440 bytes of input data and 1440 bytes of output data for the PROFINET controller.

Technical Data

PLX31-PND-MBS4 Specifications

Product type PROFINET Device to Modbus Serial gateway with four serial ports
PROFINET role Class A Device (slave)
PROFINET cyclic data 1440 bytes input and 1440 bytes output
Serial ports 4, independently configurable as master or slave
Serial standards RS-232, RS-422, RS-485
Modbus modes RTU and ASCII
Baud rate 110 to 115.2 kbps
Data bits 7 or 8
Stop bits 1 or 2
Node address 1 to 247
Commands per master port Up to 100
Internal database 10,000 16-bit registers
Ethernet connectivity 1 Ethernet port
Power supply 24 VDC nominal; 10 to 36 VDC
Current draw 300 mA nominal; 610 mA maximum
Operating temperature -25 to 70 °C
Storage temperature -40 to 80 °C
Relative humidity 5 to 95%, non-condensing
Shock 15 g operational; 30 g non-operational
Vibration 5 g, 10 to 150 Hz
Dimensions (H × W × D) 13.67 × 5.05 × 11.13 cm
Removable storage Optional SD card

Key Features

Independent Serial-Port Configuration

4

Serial Ports

Each port can be assigned its own Modbus role.

2

Modbus Modes

RTU and ASCII framing are supported.

100

Commands

Up to 100 commands per master port.

10,000

Registers

16-bit internal data registers.

System Integration

Flexible Serial Network Architecture

Mixed Serial Interfaces

The four ports support RS-232, RS-422, and RS-485. This enables connection of serial Modbus devices with different physical interfaces through one gateway.

Independent Master and Slave Roles

Each serial port can operate as a Modbus master or slave. Master ports support up to 100 configured commands, with node addresses from 1 to 247.

PLX31-PND-MBS4 four-port PROFINET and Modbus serial connection diagram
PLX31-PND-MBS4 technical port arrangement based on the official interface specifications.

Frequently Asked Questions

PLX31-PND-MBS4 FAQ

How many serial ports does the PLX31-PND-MBS4 have?

The PLX31-PND-MBS4 has four serial ports, and each port can be configured independently.

Can each PLX31-PND-MBS4 serial port operate as a Modbus master or slave?

Each PLX31-PND-MBS4 serial port can be assigned as a Modbus master or slave according to the application configuration.

Which serial interfaces and Modbus modes does the PLX31-PND-MBS4 support?

The PLX31-PND-MBS4 supports RS-232, RS-422, and RS-485, with Modbus RTU and ASCII modes.

What serial baud-rate range does the PLX31-PND-MBS4 support?

The PLX31-PND-MBS4 official specification lists baud rates from 110 to 115.2 kbps.

What PROFINET data capacity does the PLX31-PND-MBS4 provide?

The PLX31-PND-MBS4 supports 1440 bytes of PROFINET input data and 1440 bytes of output data.