Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>VIBRO METER>Meggitt Vibro-Meter CPUM Mk2 600-050 | VM600Mk2 rack controller and communications interface processing module
Meggitt Vibro-Meter CPUM Mk2 600-050 | VM600Mk2 rack controller and communications interface processing module

Meggitt Vibro-Meter CPUM Mk2 600-050 | VM600Mk2 rack controller and communications interface processing module Item NO.: 2919448

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Meggitt Vibro-Meter CPUM Mk2 600-050 | VM600Mk2 rack controller and communications interface processing module
Item NO. 2919448
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category VIBRO METER
Brand OTHER PRODUCTS
Creation Time 2026-10-14

VM600 VM600Mk2 industrial monitoring hardware
VM600 / VM600MK2 INDUSTRIAL MONITORING HARDWAREExact model profile
CPUM MK2CPUMVM600Mk2

Meggitt Vibro-Meter VM600 hardware

Meggitt Vibro-Meter CPUM Mk2 600-050 | VM600Mk2 rack controller and communications interface processing module

VM600Mk2 · processes rack data and provides controller communications
VMVM600
Part number600-050
FormatVM600Mk2 card
FamilyCPUM Mk2
Rack roleController / communications processing

Within the VM600Mk2 platform, the Meggitt Vibro-Meter CPUM Mk2 600-050 is the rack controller and communications-processing module. It coordinates rack data and provides the controller-side path toward the system’s external communications connections.

Inside a VM600Mk2 rack, CPUM Mk2 600-050 exchanges data with measurement and interface cards through the rack backplane. Its J6 and J7 RJ45 connections carry the external Ethernet path to a computer or the VM600Mk2 communications arrangement.

The controller function of CPUM Mk2 600-050 is therefore separate from the channel hardware installed beside it. Measurement cards supply the channel data, while the CPUM Mk2 processes and presents that rack data through the communications path.

Technical item
Brand Meggitt Vibro-Meter
Product type Rack controller and communications-processing module
Product family VM600Mk2
Part number 600-050
Card family CPUM Mk2
Rack interface VM600Mk2 backplane
External connectors J6 and J7 RJ45
External link Ethernet
Controller role Central rack processing
Data source Installed VM600Mk2 cards
Data destination Computer or VM600Mk2 communications path
Rack compatibility VM600Mk2 ABE04x system rack
Module width Single-width module
Rack position Front of rack, typically slot 0
Paired position IOCN Mk2 directly behind in the corresponding rear slot
Backplane connection Two connectors per module
Fieldbus capacity Up to 2 fieldbus interfaces
System Ethernet 2 × 10/100/1000BASE-T(X), up to 1 Gbps
Configuration software VibroSight software
Status and control Alarm reset, security key and module status LEDs
Rack-side input Data from installed VM600Mk2 cards
External path Computer or VM600Mk2 communications route
Connected hardware Measurement cards and IOCN Mk2
Port distinction J6/J7 external Ethernet; backplane internal

CPUM Mk2 600-050 separates the rack-side card connection from the external Ethernet route.

01 / INPUT

J6 and J7

The two RJ45 connections carry the external Ethernet path used by a computer or the VM600Mk2 communications arrangement.

→
02 / PROCESS

Backplane link

The rack backplane carries data between the CPUM Mk2 and the installed measurement and interface cards.

→
03 / OUTPUT

Data direction

Rack data reaches the CPUM Mk2 first, then leaves through the configured external communications path.

The controller function of CPUM Mk2 600-050 is to process the data presented by the VM600Mk2 rack.

FIELD PATH

Card data

Measurement and interface cards present their rack data through the backplane.

  • Controller processing

    The CPUM Mk2 handles that rack data before it is exposed to the external connection.
  • System view

    The external computer sees the rack through the CPUM Mk2 controller path rather than through a measurement card.
  • Rack role

    CPUM Mk2 600-050 remains the controller stage while the adjacent cards retain their own signal roles.

What is the data path through CPUM Mk2 600-050?

CPUM Mk2 600-050 receives rack data through the VM600Mk2 backplane, processes it at the controller level and presents the configured external communications route. The measurement inputs remain on the installed measurement cards rather than on the controller card itself.

Why can an Ethernet link be active while CPUM Mk2 600-050 shows no channel data?

The J6/J7 Ethernet path is external to the rack, while the measurement cards reach CPUM Mk2 600-050 through the backplane. A live Ethernet link therefore does not prove that the card seating, rack population or internal data path is correct.

What do J6 and J7 connect to on CPUM Mk2 600-050?

To trace CPUM Mk2 600-050, j6 and J7 are RJ45 Ethernet connections used for the computer or VM600Mk2 network path. They are not sensor terminals, so a field signal should be traced to the appropriate measurement or interface card instead.

Which parts must be checked together with CPUM Mk2 600-050?

CPUM Mk2 600-050 does not choose the external protocol. Check the 600-050 controller identity, its VM600Mk2 backplane position and the installed IOCN Mk2 or measurement-card arrangement. Those three records explain the controller path, the interface path and the channel source separately.

Can CPUM Mk2 600-050 carry the field sensor wiring directly?

No. CPUM Mk2 600-050 is the rack controller and communications processing card. Field sensor wiring terminates on the configured measurement or input interface cards, whose data then reaches CPUM Mk2 through the backplane.

How should a communication fault on CPUM Mk2 600-050 be isolated?

During a CPUM Mk2 600-050 review, separate the check into the external Ethernet cable, the controller-to-backplane connection and the installed interface or measurement cards. This sequence prevents an external link fault from being confused with missing rack data.

Our Services

MOORE AUTOMATION

https://www.mvme.cn/

Moore Automation receives industrial automation enquiries and organizes the submitted model with its requested quantity. The same request can include control cards, rack hardware and condition-monitoring components.

Service communication stays tied to the specific part string instead of reducing a request to a broad product family. This gives the enquiry a clear handoff from technical identification to response.

Model captureQuantity captureResponse path
www.mvme.cn
WAGO750-644
LenzeEVS9326-ES
Siemens6ES7151-1AA00-0AB0
GEIC695PSA040L
HoneywellCC-TFB412
Mitsubishi ElectricFR-F840-01800-2-60
OmronC500-RT002
Schneider ElectricTSXDEY32D2K
Rockwell Automation1756-L55M13
YaskawaCIMR-XCAEB0P7
BeckhoffBK2000
WAGO750-154
SEW-EURODRIVEMDX61B0008-5A3-4-0T
ABBACS355-03E-02A4-2
Siemens6FX2001-7KF10
GEIC693CMM311N
HoneywellCC-TAON01
Mitsubishi ElectricFX3S-10MR/DS
OmronC500-OC221
Schneider Electric140NOM21200
Rockwell Automation1771-WC
YaskawaSGDL-08AP
BeckhoffEL9011
Allen-Bradley1734-IE8C
WAGO750-515
SEW-EURODRIVEMC07B0015-5A3-4-00
ABBACS355-03E-03A5-2
Siemens6ES7132-6BH01-0BA0
GEIC200UEX636-C
HoneywellDC-TDOD51
Mitsubishi ElectricAJ65SBTB1-16D
OmronC200H-OC224
Schneider ElectricTM215-28BSPT
Rockwell Automation1771-IBN
YaskawaSGDS-01F31AY500
BeckhoffBK3520
WAGO750-1415
SEW-EURODRIVEMDX61B0005-5A3-4-0T
ABBACS355-03E-08A8-4+B063
Siemens6EP1437-2BA20
GEIC693PWR321Y
HoneywellCC-IP0101
Mitsubishi ElectricFX808328.5R
OmronCJ1W-ID232
Schneider ElectricTM2DDI8DT
Rockwell Automation1746-NI4
YaskawaSGDM-05DN
BeckhoffEL9100
WAGO750-506
SEW-EURODRIVEMDX61B0220-503-4-00
ABBACS355-03E-17A6A
Allen-Bradley1734-IB8
Siemens6ES7277-0AA22-0XA0
GEIC693MDL655J
HoneywellTC-IDD321
Mitsubishi ElectricFR-A024-0.2KP
OmronCJ1W-IC101
Schneider ElectricTSX1
Rockwell Automation1756-L7SP
YaskawaCIMR-EB4A0

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.