Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>GE>General Electric DS200TCTSG1A Simplex Trip Board
General Electric DS200TCTSG1A Simplex Trip Board

General Electric DS200TCTSG1A Simplex Trip Board Item NO.: 2907243

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name General Electric DS200TCTSG1A Simplex Trip Board
Item NO. 2907243
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category GE
Brand GE
Creation Time 2026-09-10

General Electric
DS200TCTSG1A
Simplex Trip Board
Mark V Speedtronic
Steam Turbine Trip · 12 Relays · ≤10 ms Response
01

Product Overview

The DS200TCTSG1A is a Simplex Trip Board (TCTS) from GE's Speedtronic Mark V turbine control system. It is designed for steam turbine applications with simplex configurations, providing essential trip functionality to ensure safe and reliable operation.

The board monitors critical operational parameters such as pressure, temperature, and flow. When parameters exceed predefined thresholds, the DS200TCTSG1A initiates a turbine trip to protect against potential damage.

This DS200TCTSG1A is populated with 12 plug-in relays and features three 16-pin connectors (JDR, JDS, JDT) and two 12-pin connectors (JN, JM). The A-rated functional revision may alter performance specifications compared to the original DS200TCTSG1 model.

02

Technical Specifications

Parameter Value
Brand General Electric (GE)
Model DS200TCTSG1A
Type Simplex Trip Board (TCTS)
Country United States
Series Speedtronic Mark V
Application Steam Turbine Trip Control
Relay Count 12 plug-in relays
Connectors 3x 16-pin (JDR, JDS, JDT), 2x 12-pin (JN, JM)
Functional Revision A-rated
PCB Coating Normal Coating
Board Group Group 1 (Mark V Series)
Weight Approx. 3.32 lbs (1.5 kg)
Operating Temperature -25°C to +70°C
03

Trip Signal Processing & Logic

T

How the DS200TCTSG1A Executes Turbine Protection

The DS200TCTSG1A handles the critical steps in the steam turbine’s protection sequence. It houses the electromechanical relays necessary to execute a trip and provides signals that open/close the electrical circuits to the trip block.

  • Monitors critical parameters: pressure, temperature, flow
  • Receives 24 V DC switch signals and analog threshold faults
  • Accepts digital trip commands from LDCC main processor
  • Signal isolation via optocouplers for reliability
  • Drives trip relays when parameters exceed setpoints
  • Independent trip logic not affected by main control program
  • Response time ≤10 ms for relay actuation
  • Outputs trip commands to fuel/steam valves for emergency shutdown
04

Relay Replacement & Maintenance

R

DS200TCTSG1A Field Service Procedures

The DS200TCTSG1A uses plug-in relays that can be replaced if they stop functioning. Original Mark V Series manual instructions must be followed due to potentially dangerous surface voltages.

  • Remove power from the drive before any relay replacement
  • Disconnect cables and remove screws securing the board
  • Use two hands to carefully remove the board from the drive
  • Wire retention clips snap off the bottom of the connector
  • Swing the retention wire over the relay to lock it under the connector
  • Static-sensitive PCB requires anti-static packaging during shipping
05

FAQ

Our DS200TCTSG1A stopped working during a turbine run and we need a replacement urgently. How do we confirm the replacement board will match our existing system?
The DS200TCTSG1A has an A-rated functional revision that may alter performance specifications from the original DS200TCTSG1 model. Before ordering, verify your existing board’s functional revision and connector layout. Check that the replacement has the same 3x 16-pin (JDR, JDS, JDT) and 2x 12-pin (JN, JM) connectors.
The DS200TCTSG1A is showing a trip condition but we cannot identify which parameter triggered it. How do we trace the source?
The DS200TCTSG1A monitors pressure, temperature, and flow parameters, initiating a trip when any value exceeds predefined thresholds. Check the LED indicators on the board for trip status, and review the Mark V HMI for fault codes. The board uses signal isolation to prevent external interference, so verify sensor inputs at the terminal board connections.
One of the relays on our DS200TCTSG1A failed. Can we replace just the relay, or do we need a new board?
The DS200TCTSG1A uses plug-in relays that can be replaced if they stop working. Remove power from the drive first, disconnect cables, remove the board, and follow GE manual instructions for relay replacement. The wire retention clips snap off the bottom of the connector, allowing you to pull the relay up and install a replacement.
We are upgrading from a simplex to a TMR turbine control system. Can the DS200TCTSG1A still be used, or do we need a different board?
The DS200TCTSG1A is specifically designed for simplex configurations, unlike TMR (Triple Modular Redundancy) systems which use a different board type. If you are upgrading to a TMR system, you would need the corresponding TMR trip board. The DS200TCTSG1A should only be used in simplex applications.
The DS200TCTSG1A has been in storage for several years. What should we check before installing it in a running turbine system?
The DS200TCTSG1A is a static-sensitive PCB with normal coating. Before installation, inspect the gold edge connector for oxidation and check all 12 plug-in relays for physical damage. Verify the functional revision matches your system requirements. Handle the board with proper ESD protection and follow the installation instructions in the Mark V manual.

Moore Automation

Moore Automation supports power generation facilities with legacy turbine control systems. Our focus is on helping plants maintain GE Speedtronic Mark V systems when original OEM support is no longer available and replacement parts become increasingly difficult to source.

We understand the urgency of turbine outages. When a trip board fails, every hour of downtime costs money. Our team provides fast quotes, verified condition reports, and shipping options that align with your maintenance window — not against it.

  • Verified condition reports with detailed photos before shipment
  • Functional revision matching for GE Mark V boards
Supported Brands
GE Bently Nevada Woodward ABB Emerson Triconex Honeywell Siemens
06

Recommended Products

GE DS200TCTGG1A
GE DS200TCTGG1AFF
GE DS200TCRAG1A
GE DS200TCEAG1A
GE DS200TCPDG1B
GE DS200TCQAG1A
GE DS200TCQCG1B
GE DS200TCDAH1B
GE DS200UCPBG6AFB
GE DS200TCPSG1APE
GE DS200LDCCH1A
GE DS200SIOBH1ACA
GE DS200FCGDH1B
GE DS200DCFBG1BJB
GE IS200VTURH2BAB
GE IS200VTURH1BAA
GE IS200EACFG1A
Bently Nevada 3500/22M
Woodward 9907-164
Woodward 5462-758B
ABB DSQC639
ABB AI835
ABB CI854AK01
ABB PM861AK01
ABB DO810
ABB SNAT603
Emerson KJ3002X1-BB1
Emerson KJ3221X1-BA1
Emerson VE4035S2B1
Emerson 1C31132G01
Emerson 5X00058G01
Triconex 3625
Triconex 3700A
Triconex 3604E
Triconex 4351B
Honeywell CC-PAIH01
Honeywell CC-PDOB01
Honeywell 51402497-200
Honeywell 51199194-100
Siemens 6ES7331-1KF02-0AB0
Siemens 6ES7315-2FJ14-0AB0
Siemens 6DD1660-0BA0
Siemens 6DP1210-8BC
Siemens 6ES5314-3UA11
Siemens 6GK7443-1EX20-0XE0
Yokogawa CP345
Yokogawa AAI143-H00
Yokogawa AMM12C
Yokogawa AAI141-S00
Schneider 140CPU65150
Schneider 140CPU67060
Schneider 140CRA93100
Schneider 140CPS11420
Bently Nevada 3500/15
Bently Nevada 3500/25
Bently Nevada 330130-040-00-00
Bently Nevada 330780-90-00
Bently Nevada 3500/42M
Woodward 9907-162
Woodward 9907-165
07

Contact Us

Manager
Leonia
WhatsApp

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.