GE Fanuc IC754CSF06CTD 6-inch QuickPanel Control Color Touch Terminal
Product Description
IC754CSF06CTD is a compact Windows CE operator-and-control platform with a 6-inch color TFT touchscreen and industrial serial, Ethernet and USB connectivity.
Color touchscreen, alarms, data entry and local visualization. QuickPanel Control configuration combines operator functions with the documented control platform. USB and Ethernet support project transfer and maintenance workflows.
Technical Specifications
Identity
- Product family
- QuickPanel Control
- Display
- 6-inch color TFT
- Resolution
- 320 × 240 pixels
- Operator input
- Resistive touchscreen
Configuration
- Processor
- Intel XScale PXA255, 300 MHz
- Flash memory
- 64 MB
- DRAM
- 32 MB
- Battery-backed SRAM
- 512 KB
- Operating system
- Windows CE
Installation and service
- Ethernet
- 10/100 Mbps interface
- Serial ports
- EIA-232/EIA-485 plus RS-232
- USB
- Two interfaces
- Power input
- 12 to 30 V DC
- Nominal power
- 24 W
- Configuration software
- CIMPLICITY Machine Edition 3.0 SP6 or later documented for this order
Commissioning Path
-
Power and grounding
Use the documented DC supply range and complete protective-earth wiring before communications testing.
-
Project tool
Keep the original Machine Edition project and confirm the required software revision before download.
-
Port recovery
Record which controller uses Ethernet and which device uses each serial channel; protocol settings are not interchangeable.
Operator, Control and Service Layers
Color touchscreen, alarms, data entry and local visualization.
QuickPanel Control configuration combines operator functions with the documented control platform.
USB and Ethernet support project transfer and maintenance workflows.
FAQ
Why can IC754CSF06CTD power up but reject a project download?
The documented configuration requires CIMPLICITY Machine Edition 3.0 SP6 or later. Check the target definition and software revision before blaming the hardware.
Which serial mode must be captured before replacing IC754CSF06CTD?
Record whether the combination port is used as EIA-232 or EIA-485, together with baud, parity, node and pinout.
Can the Ethernet link replace every serial controller connection for IC754CSF06CTD?
No. The configured driver and physical controller path determine the interface; a live Ethernet port does not recreate a serial protocol.
What is the safe DC supply range for IC754CSF06CTD?
The hardware guide documents 12 to 30 V DC. Verify polarity, protective earth and supply stability before connecting communications.
What should be saved before a memory or terminal change for IC754CSF06CTD?
Keep the editable project, target settings, runtime files, retained data, communication map and authorization information.
Why should touch calibration be included in acceptance testing for IC754CSF06CTD?
A correct display does not prove accurate operator input. Test calibration and critical controls before returning the terminal to service.