- Two output bytes arrive from the BIU in serial form.
- The module verifies transmitted data before driving the optically isolated AC switches.
- A group-fuse diagnostic returns protection status to the station.
GE Fanuc IC670MDL330 12–120 VAC Grouped Output Module
A sixteen-point grouped AC output module for switching 12–120 VAC loads.
Product Overview
GE Fanuc IC670MDL330 is a sixteen-point discrete output module for 12–120 VAC loads. The outputs form one group and switch field power supplied separately from the logic power delivered by the Field Control bus interface unit.
The BIU sends two bytes of output data to the module. IC670MDL330 converts those commands into AC load switching, returns the transmitted data for verification and reports the condition of the common output-group fuse.
Each point is rated up to 1 A, while module loading is limited by the total current and ambient-temperature derating. This distinction matters when several outputs drive lamps, contactors or other loads simultaneously.
Technical Specifications
| Product type | Grouped AC output module |
|---|---|
| Output points | 16 in one group |
| Rated voltage | 12–120 VAC |
| Output range | 10–132 VAC, 47–63 Hz |
| Maximum per point | 1 A |
| Maximum per module | 4 A with derating |
| Minimum load | 10 mA per point |
| Inrush rating | 10 A for one 20 ms cycle |
| Output voltage drop | 2.0 V maximum |
| Response | Less than 1/2 cycle on and off |
| BIU current draw | 275 mA with all points on |
Command-to-Load Route
Load Budget
- Add the steady-state current of every energized output; the module total must remain within the derated limit.
- Check inrush for coils and lamps separately from the 1 A steady-state point value.
- Use external suppression where the connected load requires it.
Buyer Questions
Can all sixteen IC670MDL330 outputs carry 1 A at once?
No. The per-point value is 1 A, but the module total is limited to 4 A and is subject to temperature derating.
What does a blown group fuse affect on IC670MDL330?
The single group fuse protects the common output supply, so its loss affects the output group and generates a diagnostic.
Is IC670MDL330 suitable for 24 V DC loads?
No. It is an AC output module for 10–132 VAC field circuits.
What should be checked for a contactor load on IC670MDL330?
Review steady-state current, coil inrush, switching frequency and any required suppression.
Which alternative to IC670MDL330 is used when isolated 2 A AC outputs are required?
IC670MDL331 provides eight outputs in four isolated groups with a 2 A per-point value.
Recommended Models
| Selection A | Selection B | Selection C |
|---|---|---|
| ABB PM850MG | Rockwell Automation 1771-IXE | Beckhoff EL3102 |
| Siemens 6EP1334-3BA00 PSU200M | Honeywell CC-TAID01 51306733-175 | SEW-EURODRIVE MDX60A0110503400 |
| GE DS215UPLAG1BZZ01A | Mitsubishi Electric FX0S-24MR-UA1 | Phoenix Contact QUINT-PS/3AC/24DC/10 |
| Omron C200HX-CPU44-E | Lenze E82EV152-4B | Moxa EDS-305-S-SC |
| Schneider Electric BMXCPS3522S | SICK CLV630-0000 | ifm PN7070 |
| Rockwell Automation 1771-A2B | Beckhoff EL4031 | ABB 3BSE005023R1 CI626A |
| Honeywell CC-TAIX01 51308363-175 | SEW-EURODRIVE MDX60A0110-503-4-00 MDX60A0110503400 8226857 | Siemens 3TK2943-0BB4 |
| Mitsubishi Electric FX4S-1P2 | Phoenix Contact QUINT-UPS/24DC/24DC/10 | GE IC698CPE020 -JR |
| Lenze E82EV152_4C | Moxa NPort 5410/EU | Omron NJ10-30GK-SN |
| SICK CLV250-1010 | ifm PN5000 | Schneider Electric A9MEM3275 |
| Beckhoff EL5151 | ABB 1SAP150100R0277 - PM591-2ETH | Rockwell Automation 1769-OW8 |
| SEW-EURODRIVE MDX60A0110503400 8226857 | Siemens 6ES7138-4CB10-0AB0 | Honeywell CC-TDOR01-RP |
| Phoenix Contact QUINT-OPS/1AC/12 | GE 0184B7360G002 | Mitsubishi Electric FX0S-30MR-DS |
| Moxa EDS-G509 | Omron NX-371 | Lenze E82EV223K4B241 |
| ifm PN3029 | Schneider Electric TSXAMZ600 | SICK CLV280-1000S03 |
| ABB 3BSE011000R1 CI630 AF100 | Rockwell Automation 1746-IA16 | Beckhoff KL6041 RS422/RS485 |
| Siemens 6ES7134-4JB50-0AB0 | Honeywell FC-PSU-UNI2450U | SEW-EURODRIVE MC07A011-5A3-4-00 |
| GE DS200UPSAG1A | Mitsubishi Electric AJ0-7510-S | Phoenix Contact QUINT4-UPS/24DC/24DC/10 |
| Omron C200H-MR431 | Lenze E82EV152K4C200 | Moxa EDS-405A-MM-ST-T |
| Schneider Electric TSXP57303AM | SICK CLV420-0910S06 | ifm IF2004B2 |









No related record found