IC610MDL115 consumes eight I/O references even though its faceplate provides four inputs and two outputs. Its relay common requires a 3 A fuse, and the two output contacts must be matched to the connected load category.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC610MDL101 / IC610MDL115 Series One Input and Fast Response I/O Modules |
| Item NO. | 2908095 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-09-14 |
IC610MDL101 and IC610MDL115 belong to the GE Fanuc Series One discrete I/O range, but they address different control tasks. IC610MDL101 is an eight-circuit 24 VDC sink input module; IC610MDL115 combines four fast-response 24 VDC inputs with two relay outputs.
They should be treated as separate hardware choices rather than interchangeable suffixes. Point allocation, internal load, response behavior and field wiring all change with the complete catalog number.
| Technical Item | IC610MDL101 | IC610MDL115 |
|---|---|---|
| Brand | GE Fanuc | GE Fanuc |
| Product Type | 24 VDC sink input module | Fast-response I/O module |
| Brand Country | United States | United States |
| I/O Circuits | 8 inputs | 4 inputs + 2 relay outputs |
| Maximum Open-Circuit Voltage | 36 VDC | 36 VDC (input) |
| Input Current | 18 mA | 16 mA maximum |
| Input Response | 4–15 ms ON; 4–15 ms OFF | 0.3–1 ms ON; 50–150 ms OFF |
| Minimum ON Current | 7 mA | 7 mA |
| Maximum OFF Leakage | 3 mA | 3 mA |
| Input Pulse Width | — | 1 ms minimum |
| Relay Operating Voltage | — | 5–265 VAC/DC |
| Relay Load | — | 4 A resistive; 0.5 A inductive |
| Output Response | — | 5 ms max ON; 5–10 ms OFF |
| Load Units | 1 at 9 VDC; 10 at 24 VDC | 16 at 9 VDC; 6 at 24 VDC |
IC610MDL101 uses field-side indicators and obtains its sensing supply from the rack, so a separate input power source is not required. Its eight input references suit standard 24 VDC state monitoring.
The official connection figure shows the shared field supply and the individual sink-input paths. Open it to check terminal grouping before transferring existing conductors.
IC610MDL115 consumes eight I/O references even though its faceplate provides four inputs and two outputs. Its relay common requires a 3 A fuse, and the two output contacts must be matched to the connected load category.
The fast-response input timing and mixed I/O layout are application-specific. Confirm program references, common wiring and the output fuse before substituting it for any input-only module.
No. IC610MDL101 is input-only, while IC610MDL115 combines fast-response inputs with fused relay outputs and uses a different reference arrangement.
No. The manual states that the rack provides the sensing supply for this module.
That is the module’s documented controller allocation; the unused physical count does not reduce its reference footprint.
Install the specified 3 A fuse in the output common line and verify that the connected load remains within the relay rating.
Record the full catalog number, input logic, assigned references, common connections and—on IC610MDL115—the relay load and fuse.
Moore Automation supports identified industrial automation requirements across PLC, I/O, drive and control ranges. Available service terms include 100% original products, fast delivery, a 1-year warranty and a 12-hour online response.
Send the complete catalog number and required quantity for product identification and order assistance.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found