The output bank separates higher-current and standard relay duties: Q1 and Q2 are the 10 A circuits, while the remaining ten outputs are 2 A circuits. All are dry relay outputs and require an external source for the connected loads.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC200UAR028 VersaMax 28-Point AC Input / Relay Output Micro PLC |
| Item NO. | 2908089 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-09-14 |
IC200UAR028 is a 28-point VersaMax Micro PLC with sixteen 120 VAC inputs and twelve normally-open relay outputs. It operates from a 100–240 VAC controller supply and combines two 10 A relay circuits with ten 2 A relay circuits for mixed load requirements.
The AC inputs receive states from externally powered field devices. The relay outputs switch separately supplied AC or DC loads, making the output side electrically distinct from the controller’s incoming power and the AC input path.
| Technical Item | Specification Value |
|---|---|
| Brand | GE Fanuc |
| Model | IC200UAR028 |
| Product Type | VersaMax 28-point AC input / relay output Micro PLC |
| Brand Country | United States |
| Inputs | 16 AC inputs |
| Outputs | 2 × 10 A relay; 10 × 2 A relay |
| Controller Power | 85–264 VAC |
| Power Frequency | 47.5–63 Hz |
| Input Voltage | 85–132 VAC, 50/60 Hz |
| Input Current | 8 mA RMS at 100 VAC, 60 Hz |
| Input Response | 25 ms max ON; 30 ms max OFF |
| Relay Operating Voltage | 5–30 VDC or 5–250 VAC |
| Relay Response | 15 ms maximum ON or OFF |
| Isolation | 1500 V RMS field-to-logic; 500 V RMS between groups |
| Weight | 600 g (1.32 lb) |
The output bank separates higher-current and standard relay duties: Q1 and Q2 are the 10 A circuits, while the remaining ten outputs are 2 A circuits. All are dry relay outputs and require an external source for the connected loads.
This arrangement lets one controller address mixed contactor, solenoid and indicator loads without treating every point as the same relay class.
The sixteen reactive input circuits require AC field power. Relay loads may use AC or DC within the stated limits, but their external sources and common groupings must follow the field wiring diagram.
Open the official figure to distinguish input commons, the two high-current relay positions and the standard relay groups before reconnecting a panel.
Q1 and Q2 are the two 10 A relay circuits; the other ten relay outputs are rated as 2 A circuits under the documented conditions.
Yes. The relay contacts accept documented AC or DC operating voltage, supplied from an external load source.
No. This model’s sixteen inputs are 120 VAC reactive input circuits and require AC power.
No. The model does not provide high-speed counter, PWM or pulse-train operation.
Those two outputs have a different relay-current class from Q3 through Q12, so the distinction affects load assignment.
Moore Automation supports requests for PLCs, modules, drives and related industrial controls. Customers can submit exact catalog numbers for a 12-hour online response, fast delivery and 100% original products.
Send the complete catalog number and required quantity for product identification and order assistance.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found