Identify
Read the complete suffix from the CPU label before selecting firmware.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | GE Fanuc IC200CPUE05-LT / IC200CPUE05-EH Ethernet CPU |
| Item NO. | 2945442 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-11-26 |
GE Fanuc · VersaMax
Two documented CPUE05 revisions with the same VersaMax CPU architecture but different firmware records.
GE Fanuc IC200CPUE05-LT / IC200CPUE05-EH identifies two revisions of the VersaMax CPUE05 PLC CPU with embedded Ethernet. Each CPU executes the application, manages local and expanded VersaMax I/O, and exchanges controller data through Ethernet plus the built-in RS-232 and RS-485 serial interfaces.
Program storage in IC200CPUE05-LT / IC200CPUE05-EH combines nonvolatile flash with battery-backed RAM inside 128 KB of configurable memory. The controller can address up to 64 modules and 2,048 I/O points, while the run/stop switch and status LEDs provide local control and state indication.
The revision record distinguishes the pair: IC200CPUE05-LT / IC200CPUE05-EH maps LT to CPU firmware 3.10 and Ethernet firmware 3.18, while EH maps to CPU firmware 2.36. The LT firmware line applies to later Jx-and-newer hardware and must not be assumed compatible with early AA–HK units.
| Technical Item | IC200CPUE05-LT / IC200CPUE05-EH |
|---|---|
| Brand | GE Fanuc |
| Product Type | VersaMax Ethernet PLC CPU revision pair |
| Brand Country | United States |
| Configurable Memory | 128 KB |
| I/O Capacity | Up to 64 modules and 2,048 points |
| Ethernet Interface | Embedded 10Base-T RJ45 |
| Ethernet Services | SRTP and Ethernet Global Data |
| Serial Interfaces | One RS-232 and one RS-485 |
| Storage | Nonvolatile flash and battery-backed RAM |
| Local Controls | Run/Stop switch |
| LT CPU Firmware | 3.10 |
| LT Ethernet Firmware | 3.18 |
| EH CPU Firmware | 2.36 |
| LT Hardware Boundary | Firmware line for Jx and later; not AA–HK |
The common hardware function of IC200CPUE05-LT / IC200CPUE05-EH must be separated from the firmware history carried by each suffix.
Read the complete suffix from the CPU label before selecting firmware.
Compare the CPU and Ethernet firmware levels with the documented revision record.
Apply the IP, SRTP and EGD settings to the verified hardware revision.
Confirm both physical link and controller-level data exchange after the revision is loaded.
The CPU firmware and Ethernet firmware are separate version records. Both must match the hardware revision because application execution and Ethernet services are updated through different firmware components.
The LT firmware line applies to Jx-and-later hardware. Loading it into an AA–HK unit is not justified by the shared CPUE05 name, because the hardware generation is part of compatibility.
The LT release addressed an Ethernet Global Data producer pause condition. Confirming the exact suffix and firmware is therefore part of diagnosing an exchange that stops even though the Ethernet link remains present.
LT firmware 3.10/3.18 is associated with Jx-and-later hardware. It is not a generic update for early AA–HK CPUE05 units.
The non-Ethernet functions of IC200CPUE05-LT / IC200CPUE05-EH remain part of the same controller record.
RS-232 and RS-485 ports provide separate physical interfaces for supported serial connections.
Battery-backed RAM holds the active program and data while the retention system is valid.
Flash provides a nonvolatile program-storage path under the selected startup settings.
The CPU scan coordinates up to 64 modules and 2,048 I/O points in the configured system.
The RS-232 and RS-485 connectors are different electrical interfaces. Cable pinout, framing and protocol parameters must match the selected port; settings from one interface cannot be transferred blindly to the other.
The CPU coordinates up to 64 modules and 2,048 I/O points through the VersaMax arrangement. Physical module count, point count, expansion layout and power limits all remain separate design checks.
Battery-backed RAM and flash provide different retention paths. A revision replacement should preserve which medium supplies the startup application as well as the actual program and hardware configuration.
A revision change should preserve serial parameters, memory source and I/O configuration as well as Ethernet settings.
No. IC200CPUE05-LT / IC200CPUE05-EH carry different documented firmware records. LT is associated with CPU 3.10 and Ethernet 3.18, while EH is associated with CPU 2.36.
For IC200CPUE05-LT / IC200CPUE05-EH, verify the full suffix and hardware generation. The LT 3.10/3.18 line is for Jx-and-later hardware and is not compatible with early AA–HK units.
IC200CPUE05-LT / IC200CPUE05-EH can control up to 64 modules and 2,048 I/O points, subject to the complete system layout and power limits.
IC200CPUE05-LT / IC200CPUE05-EH include embedded RS-232 and RS-485 serial interfaces. Keep their port parameters with the controller configuration when changing revisions.
A physical link on IC200CPUE05-LT / IC200CPUE05-EH does not confirm EGD configuration. Check IP settings, producer and consumer records, exchange IDs and revision-compatible firmware.
Back up the IC200CPUE05-LT / IC200CPUE05-EH application, hardware configuration, serial settings, Ethernet settings and the chosen RAM or flash startup behavior.
https://www.mvme.cn/
Moore Automation organizes product identification, document coordination and order communication around the submitted model record. Available label or condition information can be compared with that record before the process advances.
Moore Automation · Send the complete manufacturer, model and destination details through the contact channel that suits your request.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found