RS-232 Links
Use the unbalanced interface for an individual serial device. Hardware handshaking can be selected as RTS/CTS or RFR/CTS, or flow control can be disabled.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Emerson IC695CMM002 PACSystems RX3i Serial Communications Module |
| Item NO. | 2907979 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | GE |
| Brand | GE |
| Creation Time | 2026-09-14 |
IC695CMM002 extends the serial communication capacity of a PACSystems RX3i controller with two independent, electrically isolated ports. It occupies an RX3i Universal Backplane position and transfers port status, control information and serial data between connected devices and the RX3i CPU.
Each port can be software-selected for RS-232 or RS-485/422 electrical operation. The protocol set covers MODBUS Master, MODBUS Slave, CCM Slave, DNP3 Master, DNP3 Slave and Serial I/O. The two channels can serve separate serial links, while DNP3 operation applies a module-wide protocol constraint: if either port is assigned to DNP3, the other port must also use a DNP3 role.
It supports the full protocol set in the main CPU backplane. In supported PNS racks and CEP remote nodes, configuration is limited to MODBUS Master or MODBUS Slave. PAC Machine Edition stores the hardware configuration and maps port status and control references to the controller.
| Technical Item | Specification Value |
|---|---|
| Brand | Emerson |
| Model | IC695CMM002 |
| Product Type | PACSystems RX3i Serial Communications Module |
| Country of Origin | United States |
| Serial Ports | 2 independent, isolated ports |
| Connectors | 2 × RJ-45 |
| Selectable Baud Rates | 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K |
| Backplane Power | 0.7 A maximum at 3.3 VDC; 0.115 A maximum at 5.0 VDC |
| Operating Temperature | 0°C to +60°C |
| Turnaround Delay | 6 ms minimum |
| Input Impedance | Greater than 96 kΩ for RS-485/422; 3 kΩ to 7 kΩ for RS-232 |
| Maximum Overvoltage | ±25 V |
| Channel-to-Channel Crosstalk | -55 dB minimum |
| Port-to-Backplane Isolation | 250 VAC continuous; 1500 VAC / 1 min; 2550 VDC / 1 s |
| Port-to-Port Isolation | 500 VDC continuous; 710 VDC / 1 min |
| Internal Clock Accuracy | ±0.0105% (±9.072 s/day) from 0°C to +60°C |
IC695CMM002 keeps the channels electrically isolated from one another and from the backplane. Each port can be assigned its own serial electrical mode and communication role, subject to the DNP3 module-wide restriction.
Use the unbalanced interface for an individual serial device. Hardware handshaking can be selected as RTS/CTS or RFR/CTS, or flow control can be disabled.
Select four-wire full-duplex or two-wire half-duplex operation to match the external network topology and connected device interfaces.
MODBUS Master and Slave roles support polling or responding. CCM Slave, Serial I/O and DNP3 roles extend communication to other supported serial applications.
A PNS-managed rack can contain up to four modules and a CEP-managed node up to one. Only MODBUS Master or Slave configurations are supported in these remote positions.
Choose RS-232 or RS-485/422, then set duplex behavior, baud rate, parity, data bits, stop bits and flow control.
Configure the required master, slave or Serial I/O role. Keep both ports within DNP3 roles if either port uses DNP3.
Assign CPU reference addresses for each port's input status and output control data so application logic can monitor and command communications.
For MODBUS Master, configure external device addresses, exchange types and CPU memory locations; up to 64 exchanges can be defined.
No. If either IC695CMM002 port is configured as DNP3 Master or DNP3 Slave, the other port must also use a DNP3 role. Mixed non-DNP3 roles can be selected where the configuration permits them.
No. IC695CMM002 handles configured MODBUS Master or Slave communication through its hardware configuration, status/control references and mapped exchange data rather than application-level COMMREQ commands.
The available protocol set is reduced to MODBUS Master or MODBUS Slave. A PNS-managed remote rack supports up to four serial modules, while a CEP-managed remote node supports one.
Match the cable to the selected RS-232 or RS-485/422 mode and verify the IC695CMM002 RJ-45 pin assignment rather than assuming a generic MODBUS pinout. Use shielded cable where CE emission and immunity compliance is required.
Use the configured port status and control references. They expose communication state to application logic and provide control actions used to start or stop communication, clear errors and reset the port.
Moore Automation supplies industrial automation components across PLC, DCS, TSI, HMI, drive and control-system product ranges, including current and hard-to-find parts.
Enquiries are handled with clear product identification and responsive order communication from quotation through shipment.
Send the complete model number and required quantity for a sales enquiry.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found