Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BENTLY NEVADA>Bently Nevada 9200-03-02-10-00 | 9200 Seismoprobe Velocity Transducer
Bently Nevada 9200-03-02-10-00 | 9200 Seismoprobe Velocity Transducer

Bently Nevada 9200-03-02-10-00 | 9200 Seismoprobe Velocity Transducer Item NO.: 2929826

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bently Nevada 9200-03-02-10-00 | 9200 Seismoprobe Velocity Transducer
Item NO. 2929826
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BENTLY NEVADA
Brand Bently Nevada
Creation Time 2026-11-04

Bently Nevada 9200-03-02-10-00 9200 Seismoprobe Velocity Transducer
Bently Nevada9200 Seismoprobe

Bently Nevada 9200-03-02-10-00 | 9200 Seismoprobe Velocity Transducer

Record01

Product Overview

Bently Nevada 9200-03-02-10-00 is a two-wire moving-coil velocity transducer in the 9200 Seismoprobe family. Mechanical vibration moves the internal seismic element and produces a voltage proportional to vibration velocity without an external sensor power supply.

The complete 9200-03-02-10-00 string retains the frequency, connector/cable, mounting-base and approval selections as one installation record. Those fields control low-frequency behavior, the outgoing signal connection and the physical interface to the machine.

Because the sensor output is polarity-sensitive, the installed orientation and conductor identification must remain consistent from the transducer to the monitor input. Surface flatness, mounting torque and cable strain relief directly affect the usable measurement.

Bently Nevada 9200 Seismoprobe velocity transducer dimensional drawing
Data02

Product Data

Technical item Specification
Brand Bently Nevada
Model 9200-03-02-10-00
Product Name 9200 Seismoprobe velocity transducer
Country United States
Technology Two-wire moving-coil velocity transducer
External Power Not required
Sensitivity 20 mV/mm/s (500 mV/in/s), nominal
Signal Output Voltage proportional to vibration velocity
Frequency Selection Code 03 retained from the complete order record
Connector/Cable Selection Code 02 retained from the complete order record
Mounting Selection Code 10 retained from the complete order record
Approval Selection Code 00; no approval option stated
Transverse Sensitivity 10% or less of axial sensitivity
Temperature Range −29 to +121 °C family range
Shock Limit 50 g peak transverse family rating
Installation Control Rigid flat mount, correct orientation and strain-relieved wiring
Focus03

Operating Characteristics

Self-generating output

The moving-coil element generates its signal from vibration motion, making mount quality part of the measurement chain. The guidance below explains how the complete 9200-03-02-10-00 record is applied in the installed assembly rather than repeating isolated catalogue values.

Self-generating output

No excitation supply is needed; the monitor receives the velocity-proportional sensor voltage. Validate this behavior against the installed target and operating range used with 9200-03-02-10-00.

Low-frequency boundary

Use the selected frequency configuration only within its stated operating band and machine-speed requirement. Confirm the response after all mounting and monitor settings for 9200-03-02-10-00 are fixed.

Polarity retention

Keep conductor polarity and sensor orientation consistent so phase and direction remain meaningful. Judge the result from the complete 9200-03-02-10-00 measurement path rather than one isolated value.

Focus04

Installation Highlights

Prepare the surface

A velocity transducer requires a rigid mechanical path from the machine surface to the seismic element. The guidance below explains how the complete 9200-03-02-10-00 record is applied in the installed assembly rather than repeating isolated catalogue values.

Path 01

Prepare the surface

Use a clean, flat mounting area and the exact base hardware represented by code 10. Before closure, record the final position and hardware state for 9200-03-02-10-00.

Identify the exact 9200-03-02-10-00 interface before work begins.
Trace the connected mechanical or electrical path.
Record the verified condition before commissioning.
Path 02

Control the cable

Provide strain relief and prevent the outgoing lead from pulling or vibrating at the connector. After the mechanical work, verify cable freedom and the measurement gap for 9200-03-02-10-00.

Keep the 9200-03-02-10-00 channel and component references together.
Confirm the next device or machine boundary in the path.
Test the completed connection under its intended condition.
Path 03

Prove the channel

After mounting, compare signal polarity, running-speed response and channel noise with the expected machine condition. Finish with an inspection record that ties the mounted assembly back to 9200-03-02-10-00.

Preserve the complete 9200-03-02-10-00 identifier in the work record.
Separate mounting, wiring and signal checks during diagnosis.
Hand over the final result with the installed configuration.
Help05

Questions About This Product

Q1

Why does 9200-03-02-10-00 not need an excitation supply?

The moving-coil element in 9200-03-02-10-00 is self-generating and produces a voltage proportional to vibration velocity. The monitor input and polarity still have to match the transducer output.

Q2

What mounting problem most often degrades 9200-03-02-10-00?

A flexible, dirty or uneven surface weakens the mechanical path into 9200-03-02-10-00. Prepare a rigid mounting face and use the exact base hardware before judging low-frequency response.

Q3

How should polarity be preserved for 9200-03-02-10-00?

Keep the orientation and conductor polarity of 9200-03-02-10-00 consistent from sensor to monitor so phase and direction remain meaningful. Record any reversal made in field wiring.

Q4

What should be checked when 9200-03-02-10-00 shows unexpected low-frequency motion?

Inspect mounting rigidity, cable strain and machine-speed content for 9200-03-02-10-00. Compare the configured frequency option with the operating speed before treating the transducer as faulty.

Q5

How can cable vibration affect 9200-03-02-10-00?

An unsupported lead can feed motion into the connector or create noise around 9200-03-02-10-00. Add strain relief while leaving enough service loop to avoid pulling the sensor body.

Q6

What should a buyer state when requesting 9200-03-02-10-00?

Send 9200-03-02-10-00, quantity, mounting-base details, frequency range and connector requirement. A photo of the installed transducer helps confirm orientation without claiming a substitute.

Moore06

About Moore Automation

Moore Automation About Moore Automation

Moore Automation

https://www.mvme.cn

Moore Automation supports industrial automation enquiries across control, monitoring, drive and instrumentation hardware. Complete references, requested quantities and destination details can be kept together for a focused review.

Industrial scopePLC, DCS, drives and instrumentation.
Complete recordsExact model strings stay visible.
Available filesDocuments can follow the enquiry.
Direct routeA named contact supports communication.
Catalogue07

Related Products

FoxboroRH924ZJ
ABBPM554-RP-AC
Siemens6ES7234-4HE32-0XB0
HoneywellCC-TCNT03
FoxboroP0916FN
Bently Nevada3500/40M 125680-01
B&R7IF311.7
B&R7PS465.7
B&R3CP260.60-1
B&R3DO479.6
B&R3AI775.6
B&R3AO775.6
Bently Nevada3500/42M 135489-01
EmersonKJ4002X1-BA1
HIMAF35、F35 03/4、F35 030 11、F3 DIO 16/8 01、F3 AIO 8/4 01、F2 DO 8 01。
HoneywellCC-TAIX01
MotorolaMVME6100-0161
Siemens6EP1332-1SH71
TRICONEX3351
ABBPM5112-R-ETH
Allen-Bradley1756-L81EP
Bently Nevada3500/64M
EmersonKJ3002X1-BH1
HIMAF6214
HoneywellCC-GDOL11
Allen-Bradley1756-IB16
HIMAF3316
ABBPM5685-2ETH
HIMAF7130A
Bently Nevada3500/94 145988-01
Allen-Bradley1756-OB32
Allen-Bradley1756-OW16I
Allen-Bradley1756-CN2R
Allen-Bradley1756-DHRIO
Allen-Bradley1756-RM2XT
Allen-Bradley1756-A7
Allen-Bradley1756-A13
Allen-Bradley1756-PA72
Allen-Bradley1756-PB72
Bently Nevada330500-00-00
Siemens6ES7541-1AB00-0AB0
ABBCM576-PNIO
Bently Nevada330780-91-05
Siemens6ES7505-0RB00-0AB0
ABBTB521-ETH
Bently Nevada990-05-70-01-00
Siemens6ED1052-1MD08-0BA1
ABBSPC810ev2K02
Bently Nevada991-25-70-01-01
Siemens6ED1055-1MM00-0BA2
ABBCI865K01
Bently Nevada60R/PNL01-02-0
ABBSD833
ABBTP831
ABBPM5670-2ETH 1SAP151000R0378
Bently Nevada330854-080-24-05
Bently Nevada31000-16-10-00-050-03-02
Bently NevadaRanger Pro 70M303
Bently Nevada330103-00-25-05-02-00
Bently Nevada330902-0-95-05-02-05
Contact08

Contact Information

Moore AutomationSend the complete model and requested quantity.
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.