Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BENTLY NEVADA>Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 | 3701/55 ADAPT ESD Terminal Base Assembly with Four-Channel Relay Output Module
Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 | 3701/55 ADAPT ESD Terminal Base Assembly with Four-Channel Relay Output Module

Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 | 3701/55 ADAPT ESD Terminal Base Assembly with Four-Channel Relay Output Module Item NO.: 2926054

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 | 3701/55 ADAPT ESD Terminal Base Assembly with Four-Channel Relay Output Module
Item NO. 2926054
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BENTLY NEVADA
Brand Bently Nevada
Creation Time 2026-10-22

Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 | 3701/55 ADAPT ESD Terminal Base Assembly with Four-Channel Relay Output Module
BENTLY NEVADA · TECHNICAL RECORDMOORE AUTOMATION · INDUSTRIAL PARTS
3701/55ADAPT ESD combined record

Emergency shutdown hardware

Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 | 3701/55 ADAPT ESD Terminal Base Assembly with Four-Channel Relay Output Module

01

PRODUCT RECORD

Model Overview

The Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 record combines the ADAPT ESD terminal base assembly with its four-channel relay output module. The base provides the field-side landing and mounting interface, while the relay module presents the voted shutdown state to the connected circuit.

Within Bently Nevada 3701/55 289761-01 / 3701/55 323073-01, the triple-redundant ESD processors evaluate discrete, analog-capable and speed inputs before the relay section receives the final command. The 289761-01 base and 323073-01 module therefore belong to the same cabinet wiring and logic record.

The relay path on Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 follows the normally energized, de-energize-to-trip philosophy. Keeping both suffixes visible prevents a terminal base request from being separated from the relay hardware that must occupy its matching ADAPT ESD position.

02

ORDER AND PERFORMANCE DATA

Technical Details

This combined record keeps the 289761-01 terminal base and 323073-01 four-channel relay output module together as one 3701/55 ADAPT ESD configuration.

Brand
Bently Nevada
Model
3701/55 289761-01 / 3701/55 323073-01
Product name
ADAPT ESD terminal base assembly with four-channel relay output module
Country
USA
System family
3701/55 ADAPT ESD emergency shutdown device
Terminal base
289761-01 ADAPT ESD terminal base assembly
Relay module
323073-01 ADAPT ESD 4-channel relay output module
Processor architecture
Triple redundant; three CPUs
Discrete inputs
32 per CPU
Analog-capable inputs
12 per CPU
Speed channels
Six total speed channels
System relay capacity
12 relay outputs in the ADAPT ESD platform
Voting modes
1oo1 or 2oo3 voting
Trip philosophy
Normally energized / de-energize-to-trip
Relay status
Configured output state plus OK/NOT OK health indication
Contact boundary
External voltage, current and power limits apply
Terminal interface
ADAPT ESD terminal-base wiring
Safety platform
3701/55 ADAPT ESD SIL 3 system
03

CORE MODULE

Diagnostics and Protection

Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 carries the ESD decision from redundant processing into a monitored relay-contact state.

01

Voted command path

The processors evaluate the configured inputs before the command reaches 3701/55 289761-01 / 3701/55 323073-01; the relay module does not perform the CPU vote itself.

02

Relay health state

The 323073-01 section provides the configured output state together with OK/NOT OK information so a field circuit can distinguish a trip command from a module-health condition.

03

De-energize-to-trip behavior

The relay circuit for Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 is interpreted as normally energized, with loss of the energized state forming part of the shutdown logic.

04

CORE MODULE

System Integration

In Bently Nevada 3701/55 289761-01 / 3701/55 323073-01, the 289761-01 base, ESD processor modules and 323073-01 relay section form one cabinet-side signal path.

01

Field termination

External shutdown wiring lands on the 289761-01 terminal base before the signal reaches the matching 323073-01 relay output section.

02

Relay output boundary

The four relay channels in 3701/55 289761-01 / 3701/55 323073-01 carry the voted command to external contacts; they are not the processor input channels.

03

Module matching

The base position, connector arrangement and relay channel assignment for Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 must remain aligned with the ADAPT ESD cabinet record.

05

CUSTOMER QUESTIONS

Customer Questions

Q01

Why are Bently Nevada 3701/55 289761-01 and 3701/55 323073-01 listed together?

The Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 entry combines the terminal base that receives field wiring with the relay module that presents the voted shutdown state.

Q02

What does the 289761-01 part of Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 provide?

The 289761-01 portion identifies the ADAPT ESD terminal base assembly used to land and route the cabinet wiring in Bently Nevada 3701/55 289761-01 / 3701/55 323073-01.

Q03

Which section of Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 drives the external relay contacts?

The 323073-01 four-channel relay output module presents the command to the external circuit; the terminal base provides the physical interface.

Q04

Does Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 perform the shutdown vote?

No. The triple-redundant processors perform the configured 1oo1 or 2oo3 vote, and Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 carries the resulting command to the relay contacts.

Q05

What should be checked if Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 shows a healthy module but no field action?

Check the terminal-base landing, relay channel assignment, external contact loading and normally energized circuit state for Bently Nevada 3701/55 289761-01 / 3701/55 323073-01.

Q06

Why must the complete Bently Nevada 3701/55 289761-01 / 3701/55 323073-01 string stay on the order record?

The two suffixes identify different physical parts in the same ESD path. Removing either 289761-01 or 323073-01 leaves the cabinet and output configuration incomplete.

06

MOORE AUTOMATION

Our Services

Moore Automation

https://www.mvme.cn/

Moore Automation supports model identification, technical-record review and enquiry coordination for industrial automation parts.

The service starts with the exact part text and then keeps the relevant variant, quantity and supporting record in the same request.

Model reviewExact strings and variant fields are checked.
Technical recordsAvailable product information is organized.
Enquiry coordinationQuantity and part details remain linked.
07

CATALOGUE CROSS-REFERENCE

Related Models

  • GEIC695ACC400-DA
  • YaskawaCIMR-AC4A0072AAA
  • Emerson1C31203G01
  • Siemens3RH1921-1FA40
  • BeckhoffCX5130-0115
  • Allen-Bradley1794-TB3T
  • FANUCA06B-6151-H030#H580
  • OmronC200H-OD219
  • ABBTU505 1SAP210200R0001
  • WAGO750-613/006-000
  • Schneider ElectricBMXDRA1605
  • Phoenix ContactPLC-BSC-24DC/21
  • GEIC670MDL740J
  • YaskawaSGDH-30DE-OY
  • EmersonKJ1501X1-BC2
  • Siemens6ES7195-7KF00-0XA0
  • BeckhoffAX5103-0000
  • Allen-Bradley700-K40E-ZY
  • FANUCA05B-1523-B202
  • OmronS82K-00724
  • ABBDI810 3BSE008508R1
  • WAGO280-572
  • Schneider ElectricTSXDEY16A2
  • Phoenix ContactMCR-SL-PT100-LP-NC
  • GEIC693CPU351-GR
  • YaskawaSJDE-08ANA-0Y
  • EmersonVE801R
  • Siemens3RU2116-1AB0
  • BeckhoffKL3454
  • Allen-Bradley1794-IF2XOF2I
  • FANUCA06B-0780-B100#3000
  • OmronCS1W-CN114
  • ABBTU532/1SAP217000R0001
  • WAGO2001-1207
  • Schneider Electric140XTS00100
  • Phoenix ContactPLC-BPT-230UC/21
  • GEIC200CHS022P
  • YaskawaSGMGH-20Q5A6C
  • Emerson1C31116G03
  • Siemens3RP2525-1BW30
  • BeckhoffKL3403-0000
  • Allen-Bradley700-F040A1
  • FANUCA06B-0352-B731
  • OmronCP1W-40EDT
  • ABBTU508-ETH B8 1SAP214000R0001
  • WAGO750-514/006-000
  • Schneider ElectricTSXDEY16D2
  • Phoenix ContactMCR-SL-PT100-U-DC-24
  • GEIC693APU301R
  • YaskawaJUSP-NS115
  • EmersonVE2424
  • Siemens6ES7323-1BL00-0AA0
  • BeckhoffKL3062
  • Allen-Bradley1769-IQ16
  • FANUCA06B-0501-B755
  • OmronNJ5-18GM-N
  • ABBTU506 1SAP210000R0001
  • WAGO753-666/000-003
  • Schneider ElectricVW3A3401
  • Phoenix ContactPLC-V8/FLK14/OUT

Sales Contact

Include 3701/55 289761-01 / 3701/55 323073-01, the required quantity and the relevant system position when requesting this item.

ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.