Gap-to-output relationship
Bently Nevada 330173-00-05-10-02-00 operates over a 2.0 mm (80 mil) linear range. With the target gap set near 1.27 mm (50 mils), the probe response is passed to the Proximitor Sensor for conditioning and monitoring.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | Bently Nevada 330173-00-05-10-02-00 | 3300 5 mm M8 × 1 Proximity Probe |
| Item NO. | 2925610 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | BENTLY NEVADA |
| Brand | Bently Nevada |
| Creation Time | 2026-10-20 |
Legacy 3300 Measurement Hardware
Bently Nevada 330173-00-05-10-02-00 is a 3300 5 mm eddy-current proximity probe with an M8 × 1 threaded case and no armor. It is the sensing element in a 3300 5 mm Transducer System, where the probe converts the distance to a conductive machine target into the electrical response used for static position and dynamic vibration measurement.
In the matched signal path, Bently Nevada 330173-00-05-10-02-00 works with a 3300 XL extension cable and a compatible Proximitor Sensor. A change in probe-to-target gap changes the conditioned output; the probe itself is not a monitor, so the cable, Proximitor and monitor must remain part of the same calibrated system length.
The five suffix groups on Bently Nevada 330173-00-05-10-02-00 retain the supplied configuration: 00 selects a 0.0 mm unthreaded length, 05 selects a 50 mm case length, 10 selects a 1.0 m total length, 02 selects the standard miniature coaxial ClickLoc connector, and the final 00 indicates that an agency approval option is not required. The M8 × 1, unarmored construction is the fixed base execution identified by 330173.
Bently Nevada 330173-00-05-10-02-00 operates over a 2.0 mm (80 mil) linear range. With the target gap set near 1.27 mm (50 mils), the probe response is passed to the Proximitor Sensor for conditioning and monitoring.
The nominal scale for the 3300 5 mm system is 7.87 V/mm (200 mV/mil) with a ±6.5% tolerance. That scale links the physical gap change at Bently Nevada 330173-00-05-10-02-00 to the voltage change presented by the matched electronics.
The probe operating range is −35 to +177 °C, and the stated electrical values use an AISI 4140 steel target. The target material and the installed gap therefore remain part of the measurement setup for Bently Nevada 330173-00-05-10-02-00.
The M8 × 1 case of Bently Nevada 330173-00-05-10-02-00 is mounted so the 5.2 mm probe tip faces the conductive target with the specified gap. The mechanical mount must hold that relationship while the shaft or target moves.
The 1.0 m probe assembly uses the standard miniature coaxial ClickLoc connector identified by DD 02. The cable path is a 75 Ω triaxial FEP construction, and any field wiring must preserve shielding and the total calibrated electrical length for Bently Nevada 330173-00-05-10-02-00.
The compatible Proximitor Sensor receives the probe and extension-cable signal, provides the negative supply path and outputs the conditioned displacement or vibration signal to the monitoring system. Bently Nevada 330173-00-05-10-02-00 is therefore ordered and installed as one matched transducer-system component.
Moore Automation supports industrial automation enquiries with complete manufacturer and model records, clear quotation communication and coordinated export supply.
For 330173-00-05-10-02-00, the product identity, technical configuration and order quantity remain together so the requested Bently Nevada record is easy to review.
The complete 330173-00-05-10-02-00 string stays visible during quotation.
Industrial control, monitoring and instrumentation records can be reviewed together.
Quantity, packing and dispatch details stay linked to the enquiry.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found