Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BENTLY NEVADA>Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 | 1900/65A General Purpose Equipment Monitor
Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 | 1900/65A General Purpose Equipment Monitor

Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 | 1900/65A General Purpose Equipment Monitor Item NO.: 2925776

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 | 1900/65A General Purpose Equipment Monitor
Item NO. 2925776
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BENTLY NEVADA
Brand Bently Nevada
Creation Time 2026-10-21

Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 | 1900/65A General Purpose Equipment Monitor | Moore Automation
Bently Nevada · Machinery Monitoring HardwareMoore Automation · Technical Record

Bently Nevada · 1900/65A General Purpose Equipment Monitor

Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 | 1900/65A General Purpose Equipment Monitor

4 TRANSDUCER INPUTS · 4 TEMPERATURE INPUTS · RELAY AND RECORDER OUTPUTS

Complete model · 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00
01

Model Overview

Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 is a general-purpose equipment monitor with four transducer inputs and four temperature inputs. The two exact order strings are retained together because their option fields identify different monitor configurations within the same family.

For Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00, each transducer input can be configured for supported accelerometer, piezo-velocity or proximity-sensor signals, while channels 5–8 process thermocouples or 2- and 3-wire RTDs. Processed variables feed relay, recorder and buffered outputs.

The front-panel display, configuration software and Modbus interface provide access to the monitor values and settings for Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00. The exact suffix remains the selection record for the installed option set.

02

Technical Specifications

Brand
Bently Nevada
Complete models
1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00
Product type
General Purpose Equipment Monitor
Transducer inputs
4
Temperature inputs
4
Transducer types
Accelerometer, piezo velocity, 3-wire proximity, inductive speed
Temperature types
Type E, J, K, T thermocouples; 2/3-wire RTDs
Relay outputs
6
Recorder outputs
Four 4–20 mA outputs
Buffered output
Dedicated transducer buffered output
Speed range
100–100,000 rpm
Speed channels
Up to 4 speed measurements
Frequency bands
1–600 Hz or 4–4000 Hz
Input impedance
10 kΩ non-configurable
Temperature units
°C or °F
Digital filtering
50/60 Hz notch filtering available
Mounting
DIN rail, bulkhead or weatherproof enclosure
Communication
Modbus and configuration software path
Supply
Monitor power input per 1900/65A installation rating
03

Operating Characteristics

Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 processes multiple variable types in one compact monitor, with each channel assigned its own measurement and alarm behavior.
01

Transducer processing

The four transducer inputs on Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 accept the supported sensor families and apply configured filters before producing variables.

02

Speed and frequency

Up to four speed measurements can be calculated from proximity inputs, with the documented 100–100,000 rpm range and selected frequency pass band.

03

Temperature channels

Channels 5–8 accept Type E, J, K and T thermocouples or 2/3-wire RTDs, with values shown in °C or °F.

04

Monitoring and Control

Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 turns processed variables into local indication, relay action, recorder outputs and communications data.
01

Alarm contacts

The six relay outputs change state from the configured OK, Alert and Danger conditions of the selected variables.

02

Recorder path

Four 4–20 mA recorder outputs and a dedicated buffered output expose selected values for downstream control or recording.

03

Configuration access

The front panel, configuration software and Modbus path provide access to channel setup, status and monitor values for Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00.

05

Common Questions

Why does Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 show an unexpected engineering value?
For Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00, compare the channel sensor family, units, full-scale setting and filter with the installed transducer. A proximity input, accelerometer and temperature input cannot share one assumed scaling.
How can Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 feed a PLC without using an alarm contact as an analog value?
Use the four 4–20 mA recorder outputs or the dedicated buffered output from Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 for the selected measurement. Relay contacts represent configured states; they do not replace the analog measurement path.
What should be checked when a temperature channel on Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 is unstable?
Confirm whether the channel on Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 is configured for the installed Type E, J, K or T thermocouple, or for a 2- or 3-wire RTD. The wrong sensor type or wire arrangement changes the displayed temperature and alarm behavior.
How can a customer verify a speed alarm from Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00?
Check the selected proximity pulse source, speed-channel assignment and 100–100,000 rpm range in Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00, then compare the front-panel value with the recorder or Modbus value. This separates pulse wiring from scaling errors.
Why might a Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 relay change while the displayed value looks normal?
For Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00, compare Alert and Danger thresholds, delay settings, OK status and relay mapping. A relay can be responding to a configured state or channel fault rather than to the value currently being watched.
How can the two Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 option records be kept from being mixed?
Keep both complete Bently Nevada 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 strings on the quotation and wiring record. Their option fields identify the exact installed monitor configuration, so a shortened 1900/65A label is not enough for commissioning.
06

Monitor Options

Moore Automation

https://www.mvme.cn/

Moore Automation supports industrial automation, monitoring and instrumentation enquiries with complete model records and coordinated supply information.

The requested 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 record can stay linked to quantities, drawings and shipment details during the enquiry.

Exact model record

The complete 1900/65A-00-00-01-00-00 / 1900/65A-00-01-01-00-00 string stays visible in the enquiry.

Industrial scope

Moore Automation handles automation, monitoring and instrumentation records.

Order traceability

Quantities, drawings and shipment details remain tied to the model record.

Moore Automation

No related record found