Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>B&R>B&R X20CP0484 / X20CP0484-1 X20 Compact-S PLCs
B&R X20CP0484 / X20CP0484-1 X20 Compact-S PLCs

B&R X20CP0484 / X20CP0484-1 X20 Compact-S PLCs Item NO.: 2940465

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name B&R X20CP0484 / X20CP0484-1 X20 Compact-S PLCs
Item NO. 2940465
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category B&R
Brand B&R
Creation Time 2026-11-18

B&R X20CP0484 / X20CP0484-1 X20 Compact-S PLCs
B&R X20 System

B&R X20CP0484 / X20CP0484-1X20 Compact-S PLCs

667 MHz ARM Cortex-A92 GB onboard eMMCCompact-S assemblyPOWERLINK V2
Configuration snapshot
ProcessorARM Cortex-A9
Clock frequency667 MHz
Working memory256 MB DDR3 SDRAM / 512 MB DDR3 SDRAM
01

Product Summary

B&R X20CP0484 and X20CP0484-1 are X20 Compact-S PLCs for the B&R X20 control system. X20CP0484 and X20CP0484-1 execute the control application, operate the local X2X I/O station and exchange controller data through Ethernet and POWERLINK.

Execution in X20CP0484 and X20CP0484-1 uses the same ARM Cortex-A9 processor, while the working-memory allocation differs: X20CP0484 has 256 MB DDR3 and X20CP0484-1 has 512 MB DDR3. Both controllers keep the application on onboard eMMC and retain selected variables in FRAM, separating stored project data from live execution data and retained values.

X20CP0484 and X20CP0484-1 mount on a selected X20BB Compact-S base together with an X20PS power module and X20TB12 terminal block. The base determines whether the assembled station has zero, one or two optional interface positions and which serial or CAN connection is available, while the power module supplies the controller and the attached X20 station.

02

Specification Details

Specification X20CP0484 X20CP0484-1
Product type X20 Compact-S PLC X20 Compact-S PLC
Processor ARM Cortex-A9 ARM Cortex-A9
Clock frequency 667 MHz 667 MHz
Working memory 256 MB DDR3 SDRAM 512 MB DDR3 SDRAM
Remanent memory 64 kB FRAM; retention >10 years 64 kB FRAM; retention >10 years
Application memory 2 GB eMMC 2 GB eMMC
Shortest task class 0.4 ms 0.4 ms
Typical instruction cycle 0.0106 µs 0.0106 µs
Power consumption 2.95 W 2.97 W
Interface slots by base 0 with X20BB5x; 1 with X20BB6x; 2 with X20BB7x 0 with X20BB5x; 1 with X20BB6x; 2 with X20BB7x
Ethernet 10/100 Mbit/s 10/100 Mbit/s
POWERLINK V2 managing or controlled node, 100 Mbit/s V2 managing or controlled node, 100 Mbit/s
USB 2 × USB 1.1/2.0 Type A, 0.2 A each 2 × USB 1.1/2.0 Type A, 0.2 A each
X2X Link Master Master
Base options RS232, RS485 or RS232 + CAN depending on X20BB base RS232, RS485 or RS232 + CAN depending on X20BB base
Required assembly Base, X20PS9600/9602, X20TB12 ordered separately Base, X20PS9600/9602, X20TB12 ordered separately
Environment −25 to 60°C horizontal; −25 to 50°C vertical; IP20 −25 to 60°C horizontal; −25 to 50°C vertical; IP20
Cooling Fanless Fanless
03

Product Functions

X20CP0484 and X20CP0484-1 run the same control platform and network functions; their different working-memory capacity determines how much active application data each controller can hold.

01

Common execution behavior

The same processor platform and task timing keep program execution characteristics aligned across the pair. A model change is therefore not a way to alter network topology or base-module connections; it changes available runtime capacity.

02

Memory role separation

Working memory carries the executing program and live data, FRAM retains configured variables, and eMMC stores the application image. Treating these as separate resources prevents a retained-variable problem from being mistaken for an application-storage failure.

03

Project-target validation

A project transferred between the two order numbers must be built for the selected controller and checked against actual memory use. The larger-memory model provides capacity, but it does not remove runtime, library or hardware-configuration requirements.

04

Installation Highlights

A complete X20 Compact-S station is assembled from the controller, a selected base, a power module and the terminal block; the base determines the available expansion and serial options.

01

Choose the base first

The X20BB family selected for the station establishes the number of optional interface positions and any base-level serial or CAN connection. This choice should be recorded before the CPU is removed because it is not encoded by the controller order number.

02

Build the power path

The X20PS power module and terminal block complete the station supply and wiring interface. Confirming their order numbers and conductor positions keeps the replacement aligned with the installed I/O load and cabinet wiring.

03

Verify the assembled configuration

After the CPU is seated on the Compact-S assembly, compare the installed base and optional interfaces with the project hardware tree. Mechanical fit confirms assembly only; normal startup still depends on the configured hardware matching the physical station.

05

Questions & Answers

01FAQ

What is the practical difference between X20CP0484 and X20CP0484-1?

X20CP0484 and X20CP0484-1 share processor speed, FRAM, eMMC and interfaces, but X20CP0484-1 provides 512 MB DDR3 instead of the 256 MB fitted to X20CP0484.

02FAQ

Can X20CP0484 and X20CP0484-1 use the same Compact-S base?

X20CP0484 and X20CP0484-1 use the same X20BB5x, X20BB6x or X20BB7x base families, but the chosen base must match the required interface slots and serial/CAN option.

03FAQ

Why is a CPU-only order incomplete for X20CP0484 and X20CP0484-1?

X20CP0484 and X20CP0484-1 require a separate Compact-S base, X20PS9600 or X20PS9602 power module and X20TB12 terminal block to form the installed station.

04FAQ

How should a project be migrated between X20CP0484 and X20CP0484-1?

For X20CP0484 and X20CP0484-1, verify Automation Runtime compatibility, project memory use, base configuration and network settings before loading the archived project to the replacement.

05FAQ

What causes USB devices to overload X20CP0484 and X20CP0484-1?

Each USB port on X20CP0484 and X20CP0484-1 is rated for 0.2 A, so high-current service devices should not be assumed compatible without checking their demand.

06FAQ

Which temperature rule applies to X20CP0484 and X20CP0484-1?

X20CP0484 and X20CP0484-1 use orientation-dependent limits and the selected X20PS960x derating instructions; confirm cabinet temperature, mounting direction and I/O load together.

06

Brand Supply Scope

Moore Automation

https://www.mvme.cn/

Moore Automation organizes requests by both manufacturer and hardware function. This keeps a controller, terminal, base, communication card or power module from being quoted as an interchangeable family name.

Controllers and processors
I/O and communication
Operator interfaces
Drive and power hardware
PRODUCT GROUP 01

Control hardware

CPUs, controllers, racks and system power components are identified separately.

PRODUCT GROUP 02

Field connectivity

Input, output, terminal, base and communication modules retain their individual order numbers.

PRODUCT GROUP 03

Machine interface

HMI, drive, motion and monitoring items are grouped without removing their model suffixes.

Contact DetailsMoore Automation

CompanyMoore Automation
ManagerLeonia

No related record found

You May Also Like

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.