Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>ABB>ABB PM5072-T-2ETHW 1SAP124400R0173 Wide-Temperature Pro CPU
ABB PM5072-T-2ETHW 1SAP124400R0173 Wide-Temperature Pro CPU

ABB PM5072-T-2ETHW 1SAP124400R0173 Wide-Temperature Pro CPU Item NO.: 2931701

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name ABB PM5072-T-2ETHW 1SAP124400R0173 Wide-Temperature Pro CPU
Item NO. 2931701
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category ABB
Brand ABB
Creation Time 2026-11-11

ABB PM5072-T-2ETHW 1SAP124400R0173 | Wide-Temperature Pro CPU
ABB · AC500-eCo V3PM5072Wide-Temperature Pro CPU
Model and order code together

ABB PM5072-T-2ETHW 1SAP124400R0173 Wide-Temperature Pro CPU

An AC500-eCo V3 Pro CPU with integrated digital I/O, dual switched Ethernet and a wide operating-temperature design.

01

Product Introduction

ABB PM5072-T-2ETHW 1SAP124400R0173 is the wide-temperature member of the AC500-eCo V3 Pro CPU range. It combines controller execution, twelve 24 V DC digital inputs, eight transistor outputs, two configurable 24 V DC channels and two independent Ethernet interfaces with an internal switch in one compact station.

The CPU provides 8 MB total user-program memory, including 1 MB for user program code and data plus up to 7 MB for web data. Three option slots allow supported communication or function boards to be added without changing the main CPU, while the onboard I/O handles local discrete signals close to the controller.

The W designation matters when specifying ABB PM5072-T-2ETHW 1SAP124400R0173: it is intended for an extended temperature environment, with catalog conditions reaching -40 to +70 °C from production index B0 and possible derating depending on the installation. The complete model and order code should therefore stay together in purchasing and project records.

02

Technical Information

Brand ABB
Model PM5072-T-2ETHW 1SAP124400R0173
Product name AC500-eCo V3 Wide-Temperature Pro CPU
Country China / Germany / Finland
Total user memory 8 MB
Program code and data 1 MB
Web data Up to 7 MB
Digital inputs 12 × 24 V DC
Transistor outputs 8 × 24 V DC
Configurable DC channels 2
Ethernet interfaces 2, independent with switch
Option slots 3
Supply voltage 24 V DC
Temperature version Wide range, W
Net weight Approx. 0.265 kg
03

Performance Highlights

ABB PM5072-T-2ETHW 1SAP124400R0173 balances local I/O, application memory and network access for compact machines that need more than a basic controller.

Control resources

Keep logic and web content separated

The 8 MB total allocation includes a defined 1 MB program-and-data area and up to 7 MB of web data. Project sizing should check both limits, because unused web capacity does not automatically expand the user program allocation.

Integrated I/O

Handle local signals without a separate rack

Twelve inputs collect 24 V DC states, eight transistor outputs command DC loads and two configurable channels support the documented input or output use. Commons, field supplies and channel modes are planned before wiring so the program matches the physical terminal assignment.

Temperature design

Preserve margin in demanding enclosures

The wide-temperature version expands environmental capability, but enclosure temperature, loading and derating still require review. Ventilation, adjacent heat sources and supply quality should be assessed under the actual duty rather than relying only on the headline range.

04

Configuration and Programming

A reliable ABB PM5072-T-2ETHW 1SAP124400R0173 project ties hardware identity, Ethernet roles and option-slot configuration to the same controller record.

Match the exact CPU and installed options

Select the PM5072-T-2ETHW hardware in the engineering project, add each option board in its physical slot and set the two configurable DC channels to their wired role. A generic CPU entry can hide slot or I/O differences during download.

Assign the two ports deliberately

The independent Ethernet interfaces can be used with the internal switching capability, but topology and protocol roles still need documented addresses and network boundaries. Confirm engineering access, controller communication and any managed-switch requirements before field connection.

Release outputs in controlled stages

Download with field loads isolated, confirm CPU and option-board diagnostics, then exercise inputs and outputs one group at a time. Check that the wide-temperature module has the supported project and firmware level before placing the machine in automatic operation.

05

Frequently Asked Questions

Why can ABB PM5072-T-2ETHW 1SAP124400R0173 communicate on one Ethernet port but not the other?

For ABB PM5072-T-2ETHW 1SAP124400R0173, compare the configured interface role, IP settings, cable, switch path and protocol assignment for each port. The presence of two interfaces does not make separate networks interchangeable unless the project and topology are designed that way.

What should be checked before using ABB PM5072-T-2ETHW 1SAP124400R0173 below 0 °C?

Verify the production index, enclosure conditions, supply limits, condensation control and any required derating for ABB PM5072-T-2ETHW 1SAP124400R0173. Temperature capability does not remove the need to keep moisture and rapid thermal transitions under control.

Why does ABB PM5072-T-2ETHW 1SAP124400R0173 reject a project after CPU replacement?

ABB PM5072-T-2ETHW 1SAP124400R0173 may have a different firmware level, hardware selection or option-slot record from the project backup. Confirm the exact W model and order code, supported engineering version, firmware compatibility and installed options before downloading.

How should configurable channels be verified on ABB PM5072-T-2ETHW 1SAP124400R0173?

For ABB PM5072-T-2ETHW 1SAP124400R0173, compare each terminal wire with the project mode, field supply and I/O mapping. Test the channels individually with loads isolated so an input configured as an output, or the reverse, is found before automatic operation.

What can cause a transistor output on ABB PM5072-T-2ETHW 1SAP124400R0173 to stay off?

Check the field supply, output-group common, channel assignment, diagnostic status and connected load on ABB PM5072-T-2ETHW 1SAP124400R0173. A healthy CPU does not prove that the separate 24 V DC load path is present.

What information should be recorded before replacing ABB PM5072-T-2ETHW 1SAP124400R0173?

For ABB PM5072-T-2ETHW 1SAP124400R0173, save the project, firmware, IP settings, option-board positions, configurable-channel modes and terminal labels. Preserve the full order code so a standard-temperature PM5072 is not substituted for the W version.

06

Why Choose Moore Automation

Moore Automation

https://www.mvme.cn

Moore Automation handles controller enquiries with the model, order code and project context kept in one record. This is especially useful for ABB CPUs whose memory, temperature version and communication arrangement may change across similar names.

For ABB PM5072-T-2ETHW 1SAP124400R0173, the W suffix and 1SAP order code are retained through review, quotation and packing so the wide-temperature request is not reduced to a generic PM5072 description.

Exact identityModel and 1SAP code paired
Project contextOptions and network noted
Practical reviewEnvironment considered
07

Selected Products

Rockwell Automation1783-CMS10P
Rockwell Automation1783-CMS20DN
Rockwell Automation1783-CMS20DP
Rockwell Automation1783-CMS6P
Rockwell Automation1783-MMS10R
Rockwell Automation1783-US16T
Rockwell Automation1783-USP16T
Rockwell Automation1783-USP1S4T
Rockwell Automation1783-USP2S6T
Rockwell Automation1783-USP5TGK
Rockwell Automation2711P-T4W22D8S
Rockwell Automation2711P-T9W22D9P
Rockwell Automation2715P-T7WD
Siemens3RH5921-1FA22
GEIC655CHS506
GEIC655CHS508
GEIC655MDL501
GEIC655MDL502
GEIC655MDL503
GEIC655MDL511
GEIC655MDL512
GEIC655MDL525
GEIC655MDL526
GEIC655MDL527
GEIC655MDL533
GEIC655MDL551
GEIC655MDL552
GEIC655MDL555
GEIC655MDL556
GEIC655MDL575
GEIC655MDL576
GEIC655PWR500
GEIC655PWR501
GEIC655PWR514
Siemens6ES7132-4HB01-0AB0
Siemens6ES7193-7CA00-0AA0
Siemens6ES7648-2AF50-0JB0
Siemens6GK1901-1BB10-2AA0
Siemens6SL3210-5BE13-7UV0
Rockwell Automation80026-044-02
Rockwell Automation80026-529-01-R
Rockwell Automation80190-099-01/7
Rockwell Automation80190-100-01-R
Rockwell Automation80190-560-01-R
Rockwell Automation81000-199-51-R
Rockwell Automation81001-451-61-R
Rockwell Automation81001-451-63-R
ABBNTAI02
ABBNTAI04
ABBNTAO02
ABBNTCL01
ABBNTCS04
ABBNTDI01
ABBNTDI02
ABBNTDO02
ABBNTHS03
ABBNTMF01
ABBNTMP01
ABBNTRL02B
ABBNTST01
08

Contact & Enquiry

Plan the wide-temperature CPU enquiry
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.