Welcome to Moore Automation Limited

0
Loadding...
 

sales@mvme.cn    Phone: +86 18030175807

Home>BENTLY NEVADA>Bently Nevada 9755-17 17 ft Test Interconnect Cable
Bently Nevada 9755-17 17 ft Test Interconnect Cable

Bently Nevada 9755-17 17 ft Test Interconnect Cable Item NO.: 2931700

Write a Review
US$ 1.00
Quantity
Stock ( 28 )

Copy and share this link on social network or send it to your friends

Copy
Request Price & AvailabilitySend the part number and quantity. Our team will confirm stock, condition, lead time and the best quotation.
  • MOQ: 1 piece
  • International shipping
  • 1-year warranty on eligible items
  • Fast response during business hours
Product Name Bently Nevada 9755-17 17 ft Test Interconnect Cable
Item NO. 2931700
Weight 0.1 kg = 0.2205 lb = 3.5274 oz
Category BENTLY NEVADA
Brand Bently Nevada
Creation Time 2026-11-11

Bently Nevada 9755-17 | 17 ft Test Interconnect Cable
Bently Nevada · 9200 / 74712 Seismoprobe Accessories975517 ft Test Interconnect Cable
9755-NN length code decoded

Bently Nevada 9755-17 17 ft Test Interconnect Cable

A 17 ft two-wire shielded test cable with a 2-pin female connector at each end for connecting 9200 or 74712 Seismoprobe transducers to Bently Nevada test kits.

01

Product Overview

Bently Nevada 9755-17 is a test interconnect cable for 9200 and 74712 Seismoprobe velocity transducers. It connects the transducer to a compatible Bently Nevada test kit so technicians can evaluate the sensor without substituting a general-purpose field cable.

The manual defines the family as 9755-NN, where NN is the desired cable length in feet. The suffix 17 therefore specifies a 17 ft cable, equal to approximately 5.18 m. The construction is two-wire shielded 22 AWG (0.5 mm²) cable with a 2-pin female connector at each end, distinguishing it from 83968-NN cables that terminate in a coaxial connector for instruments with BNC inputs.

Bently Nevada 9755-17 is a diagnostic accessory rather than a permanently mounted velocity transducer. Its condition matters during troubleshooting because an open conductor, shield fault or worn connector can make a healthy Seismoprobe appear unstable or unresponsive.

02

Product Data

Brand Bently Nevada
Model 9755-17
Product name Seismoprobe Test Interconnect Cable
Country United States
Cable family 9755-NN
Specified length 17 ft / 5.18 m
Length-code rule NN equals cable length in feet
Conductors 2
Wire size 22 AWG / 0.5 mm²
Shielding Shielded
Connector end A 2-pin female
Connector end B 2-pin female
Compatible transducers 9200 and 74712 Seismoprobe
Intended connection Transducer to Bently Nevada test kit
Operating temperature -70°C to +150°C
Orderable family range 1 ft to 99 ft
03

Test-System Integration

The role of Bently Nevada 9755-17 is to reproduce a clean, known connection between a Seismoprobe and the appropriate diagnostic kit.

Correct endpoints

Use two female 2-pin terminations

Both ends of the 9755 cable use the 2-pin female interface specified for the Seismoprobe-to-test-kit path. Check connector keying and pin condition before insertion; forcing a connector can spread contacts and create an intermittent test lead.

Defined length

Treat 17 as feet, not a revision code

The family suffix directly states cable length, so 9755-17 is 17 ft long. Record that length with the test setup, especially when comparing results from different leads or routing the cable away from energized equipment.

Signal integrity

Keep the shield continuous through the test

A velocity-transducer test can be corrupted by ground loops or electromagnetic pickup. Use the cable as documented, keep it clear of switching conductors and verify shield and conductor continuity when the measured noise floor changes unexpectedly.

04

Cable Handling and Diagnostics

Routine inspection of Bently Nevada 9755-17 prevents a reusable test accessory from becoming an invisible source of false diagnoses.

Look for wear at both connector transitions

Check the jacket, strain relief, shells, keying and contact cleanliness before connecting a transducer. Reject a lead with crushed sections, exposed shield or loose pins instead of compensating for the fault in the test result.

Prove conductors and isolation end to end

With the cable disconnected, verify each intended pin path, absence of cross-conductor shorts and shield isolation according to the test-kit procedure. Gently move the cable during the check to reveal a break that appears only when flexed.

Coil without twisting or tight bends

Clean and cap both connectors, form a broad natural coil and label the 17 ft length visibly. Separate the cable from heavy tools and hot surfaces so the wide temperature rating is not mistaken for permission to damage it mechanically.

05

Questions About This Product

What does the 17 mean in Bently Nevada 9755-17?

In Bently Nevada 9755-17, the 9755-NN ordering rule uses NN for cable length in feet. The suffix 17 therefore specifies a 17 ft, approximately 5.18 m, test interconnect cable.

Why will Bently Nevada 9755-17 not connect to a BNC input directly?

Bently Nevada 9755-17 has a 2-pin female connector at both ends for Bently Nevada test kits. A setup requiring a coaxial connector at the instrument end uses a different documented cable family, so an improvised BNC adapter should not be assumed equivalent.

How can Bently Nevada 9755-17 be checked when a Seismoprobe appears dead?

Disconnect Bently Nevada 9755-17 and test both conductors, shield continuity and isolation while gently flexing the lead. Inspect both 2-pin female connectors, then repeat the Seismoprobe test with a known-good compatible cable if the procedure allows.

Can Bently Nevada 9755-17 be left as permanent machine wiring?

Bently Nevada 9755-17 is documented as a connection from 9200 or 74712 Seismoprobe transducers to Bently Nevada test kits. Permanent field wiring should follow the transducer installation design rather than treating this diagnostic lead as a plant cable.

What routing reduces noise during tests with Bently Nevada 9755-17?

Route Bently Nevada 9755-17 away from variable-frequency drive output leads, contactors and high-current conductors, avoid a large loop area and keep connectors fully seated. If noise persists, verify shield integrity before judging the transducer.

How should Bently Nevada 9755-17 be identified in the tool store?

Label Bently Nevada 9755-17 with the full part number, 17 ft length, two-female-connector arrangement and latest continuity-test status. Cap the connectors and use a broad coil so the next technician receives a known diagnostic lead.

06

About Moore Automation

Moore Automation

https://www.mvme.cn

Moore Automation supports industrial maintenance teams with model-focused sourcing, document review and practical enquiry coordination. The product identity stays visible from initial request through packing and delivery communication.

For Bently Nevada 9755-17, the 9755 cable family, decoded 17 ft length and two-female-connector arrangement can be recorded together, helping buyers distinguish this test lead from similarly numbered permanent or BNC-ended cables.

Model clarityLength suffix decoded
Accessory matchingConnector use distinguished
Enquiry continuityTechnical record retained
07

Related Products

Siemens3RU2916-3AA01
GEIC655CPU500
GEIC693PCM301
GEIC697BEM711
GEIC697BEM713
GEIC697BEM731
GEIC697BEM733
GEIC697CGR772
GEIC697CGR935
GEIC697CMM711
GEIC697CPU780
GEIC697CPU781
GEIC697CPU782
GEIC697CPU788
GEIC697CPU789
GEIC697CPX772
GEIC697CPX782
GEIC697CPX928
GEIC697PWR711
GEIC697PWR724
GEIC697PWR748
ABBIMSER02
ABBIMSET01
ABBIMSPM01
ABBINICT12
ABBINICT13
ABBINIIT12
ABBINIIT13
ABBINNIS21
ABBINNPM12
ABBINNPM22
ABBIPMON01
ABBIPSYS01
Siemens6ES7131-4BD00-0AB0
Siemens6ES7193-4CG30-0AA0
Siemens6ES7392-1BM01-0AA0
Siemens6ES7972-0BA12-0XA0
Siemens6ES7972-0BA41-0XA0
ABBNROI01
Rockwell Automation1746-IB32
Rockwell Automation1746-NIO4V
Rockwell Automation1746-NO4I
Rockwell Automation1746-OB32
Rockwell Automation1747-AIC
Rockwell Automation1747-ASB
Rockwell Automation1747-L531
Rockwell Automation1747-L532
Rockwell Automation1747-L541
Rockwell Automation1747-L542
Rockwell Automation1747-L543
Rockwell Automation1747-L551
Rockwell Automation1747-L552
Rockwell Automation1747-L553
Rockwell Automation1783-BMS10CGN
Rockwell Automation1783-BMS10CGP
Rockwell Automation1783-BMS12T4E2CGNK
Rockwell Automation1783-BMS12T4E2CGP
Rockwell Automation1783-BMS20CGN
Rockwell Automation1783-BMS20CGP
Rockwell Automation1783-CMS6B
08

Contact Information

Request the exact 17 ft Seismoprobe test lead
ManagerLeonia

No related record found

Copyright © 2004–2026 www.mvme.cn. All rights reserved.

Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.