CI868 IEC 61850 path
CI868AK01 maps configured IEC 61850 communication through the controller project and the two isolated TP867 Ethernet channels.
Welcome to Moore Automation Limited
Copy and share this link on social network or send it to your friends
Copy| Product Name | ABB CI868AK01 3BSE092691R1 / CI873AK01 3BSE092695R1 Ethernet Interface Kits |
| Item NO. | 2928406 |
| Weight | 0.1 kg = 0.2205 lb = 3.5274 oz |
| Category | ABB |
| Brand | ABB |
| Creation Time | 2026-10-30 |
ABB CI868AK01 3BSE092691R1 / ABB CI873AK01 3BSE092695R1 are AC 800M CEX-bus Ethernet interface kits. CI868AK01 connects the controller to IEC 61850 station communication, while CI873AK01 connects the controller to EtherNet/IP devices; the protocol role is fixed by the exact kit.
Both ABB CI868AK01 3BSE092691R1 / ABB CI873AK01 3BSE092695R1 place CPU, memory, logic and dual Ethernet transceivers between the CEX bus and the TP867 RJ45 channels. Galvanic isolation belongs to each Ethernet path, while controller data and configuration pass through the CEX interface.
A project using ABB CI868AK01 3BSE092691R1 / ABB CI873AK01 3BSE092695R1 reserves the correct CEX position, installs the TP867 base and maps the protocol objects for the selected interface. Swapping the two articles without changing the project cannot convert IEC 61850 traffic into EtherNet/IP traffic.
| Technical item | CI868AK01 3BSE092691R1 | CI873AK01 3BSE092695R1 |
|---|---|---|
| Brand | ABB | |
| Product Name | IEC 61850 Communication Interface Kit | EtherNet/IP Communication Interface Kit |
| Country | Switzerland | |
| System Family | AC 800M | |
| Protocol | IEC 61850 | EtherNet/IP |
| Controller Connection | CEX bus | |
| Baseplate | TP867 | |
| Ethernet Channels | 2 × isolated 10/100Base-TX | |
| Processor | MPC862P, 96 MHz | |
| SDRAM | 32 MB | |
| Flash Memory | 4 MB | |
| Power Source | 24 V from CEX bus | |
| Front Indication | Six status / network LEDs | |
| Kit Contents | CI868A + TP867 | CI873A + TP867 |
| Software Boundary | 800xA 6.0.3.3 / 6.1.1 or later | 800xA 6.0.3.3 / 6.1.1 or later |
CI868AK01 maps configured IEC 61850 communication through the controller project and the two isolated TP867 Ethernet channels.
CI873AK01 maps EtherNet/IP connections and device data through the same physical channel arrangement without using the IEC 61850 object model.
CEX traffic reaches the local CPU and memory before the two Ethernet transceivers and isolation stages drive CH1 and CH2.
Install the documented interface and TP867 in the planned expansion position with the CEX bus de-energized and correctly terminated.
Configure either IEC 61850 or EtherNet/IP objects for the installed article, then bind them to the controller application rather than copying the other interface type.
Restore power, confirm interface and link indications, then exchange representative data through each channel with the external station or device.
Moore Automation covers industrial control and monitoring references from ABB, Honeywell, Siemens, Rockwell Automation, Schneider Electric and other established brands.
The product scope includes controllers, communication interfaces, distributed I/O and related automation hardware with exact model records retained for each enquiry.
Moore Automation Sales Team
Copyright © 2004–2026 www.mvme.cn. All rights reserved.
Disclaimer: Moore Automation Limited is an independent reseller and is not an authorized distributor or representative of the manufacturers featured on this website. Product names and trademarks belong to their respective owners.
No related record found